CONTROL WIRING<br />
GROUND<br />
(Optional)<br />
ALARM<br />
NO<br />
C<br />
MAGLOCK<br />
NO<br />
C<br />
NC<br />
Z1<br />
GATE 1<br />
ACCESSORY<br />
POWER<br />
GATE 2<br />
10A 32V<br />
D1Ø<br />
D15<br />
R4 C2<br />
R196<br />
J4<br />
BRN<br />
GRN<br />
WHT<br />
YEL<br />
BLU<br />
RED<br />
Z12<br />
BRN<br />
24V<br />
GRN<br />
WHT<br />
YEL<br />
BLU<br />
RED<br />
R9Ø<br />
24 VAC/<br />
SOLAR<br />
INPUT<br />
GREEN/YELLOW<br />
150VA<br />
TORROID<br />
TRANSFORMER<br />
MOV2<br />
K6<br />
K2<br />
R1Ø1<br />
K5<br />
R1ØØ<br />
J19<br />
F5<br />
L1<br />
SET<br />
K1 Q9<br />
OPEN<br />
LIMIT<br />
K4<br />
D21<br />
K3<br />
D8<br />
Q22 D22<br />
J1<br />
ACCESSORY<br />
OVLD<br />
MOV1<br />
JMPR2<br />
DB1<br />
C11<br />
J4<br />
FORCE<br />
Ø14GPØ89ØE<br />
Ø14LGØ89ØE<br />
Ø14SKØ89ØE<br />
1 S8 OFF<br />
1<br />
ON SAVE<br />
R2<br />
OFF<br />
2<br />
ON MAGLOCK<br />
LEARN SINGLE<br />
3<br />
DUAL MODE<br />
R1 XMITTER<br />
4<br />
NO NC EDGE<br />
5<br />
NO NC PHOTO<br />
2<br />
S1<br />
F3<br />
10A 32V<br />
F4<br />
DIAGNOSTIC<br />
BIPART<br />
DELAY<br />
P2<br />
P1<br />
U4<br />
J18<br />
TIMER TO<br />
CLOSE<br />
MIN MAX OFF MAX OFF MAX<br />
C12<br />
GATE 1<br />
SET<br />
LEARN<br />
CLOSE<br />
LIMITS<br />
LIMIT<br />
TIMER<br />
GATE 2<br />
RUNNING<br />
R35<br />
D9<br />
D27 Z3<br />
Z4<br />
U3<br />
R9<br />
D4<br />
C64<br />
D1<br />
JMPR1<br />
U2<br />
D2<br />
USE DEDICATED CIRCUIT<br />
O N<br />
D6<br />
F7<br />
C13<br />
F6<br />
F2<br />
R2Ø7<br />
R224<br />
SINGLE<br />
BUTTON<br />
C4<br />
Z2Ø<br />
R227<br />
R223<br />
Z22<br />
R92<br />
R91<br />
R94<br />
R93<br />
OPEN<br />
SINGLE BUTTON<br />
RESET<br />
STOP<br />
COM<br />
COM<br />
POWER<br />
SHADOW<br />
INTERRUPT<br />
CHGR COM<br />
OVLD<br />
FUSE<br />
OPEN<br />
F1 2ØA 32V<br />
BATT 2 BATT 1<br />
24 VAC/<br />
SOLAR<br />
INPUT<br />
OR<br />
7<br />
CLOSE<br />
EDGE<br />
OPEN EDGE/<br />
PHOTO<br />
Z9<br />
OPEN<br />
PHOTO<br />
Z8<br />
CLOSE<br />
PHOTO<br />
24V<br />
SWITCHED<br />
ACCESSORY<br />
COM OVLD POWER<br />
OVLD<br />
To reduce the risk of FIRE or INJURY to persons use only<br />
Chamberlain parts for replacement batteries.<br />
CONTROL<br />
INPUTS<br />
LOOP<br />
INPUTS<br />
MOV2<br />
BATT 2 BATT 1<br />
BATTERY WITH CHARGE TRANSFORMER<br />
The main source of power are the batteries. The batteries<br />
can be charged in circuit by using a charging transformer<br />
or solar panels.<br />
BATTERY WITH RUN TRANSFORMER<br />
The main source of power is the transformer.<br />
The batteries may or may not be used. Batteries<br />
if installed function as back-up to open the gate<br />
in case of a power outage.<br />
Transformer must be removed from the backsi<strong>de</strong><br />
of the control board if batteries are installed.<br />
POWER IN<br />
The 24Vac input can accept a charging transformer or the run<br />
transformer. I<strong>de</strong>ally the charge transformer is installed at the<br />
house and a low voltage line is used to the control board at the<br />
gate.<br />
The run transformer is installed in the control box.<br />
SOLAR PANELS<br />
Optional solar panels may be used to charge the batteries. Solar<br />
Panels must be a minimum of 27.4V, 9W output.