<strong>VC</strong>-<strong>G20SM</strong>/<strong>G200SM</strong><br />

<strong>VC</strong>-<strong>G201SM</strong>/<strong>G401SM</strong><br />

SERVO CIRCUIT ADJUSTMENT<br />

ADJUSTMENT OF HEAD SWITCHING POINT<br />

Measuring<br />

instrument<br />

Mode<br />

Cassette<br />

Test point<br />

Specification<br />

Oscilloscope<br />

Playback<br />

Aligment Tape (VROCBZF)<br />

Pin(2) of TP201 (H.SW.P.) to CH-<br />

1, VIDEO OUT jack to CH-2<br />

(CH-1 trigger slope switch at (+),<br />

Internal trigger at CH-1 side.)<br />

6.5 ± 0.5H (lines)<br />

1. Insert the Aligment Tape (VRO-CBZF) and set to PB Mode.<br />

2. Transmit the TEST code (R/C code 47H) to <strong>VC</strong>R.<br />

Or, once, short the TP801 at the main PWB<br />

(By doing this,LCD will all light up and become the PB<br />

Tracking Center value.<br />

~ As for the recover equipment,prepare the memory-remote<br />

control.<br />

But,while adjust the running, at non cassete control unit<br />

condition but have the cassete control JP(TP801 short on<br />

the main PWB), if press TRACKING UP and DOWN key at<br />

the same time, it'll become the TRACKING CENTER (for<br />

Running Ajustment)<br />

3. Again, transmit the PLAY (PB), or Press PLAY Key.After<br />

AUTO PG ADJ mode is finished, make sure the PB Switching<br />

Point is inside standard range.<br />

~ During Flashing of PLAY(casette mark) is AUTO PG ADJ,<br />

finish the AUTO PG ADJ,by light off.<br />

~ When using the manual PG ADJ,finish the No.2, and it is<br />

able to adjust the PG using FF key or REW key.<br />

ADJUSTMENT OF PAL SYSTEM SP/LP SLOW<br />

TRACKING PRESET<br />

Measuring<br />

instrument<br />

Mode<br />

Cassette<br />

Monitor Screen<br />

Playback<br />

Self-recorded tape<br />

(SP/LP mode)<br />

Control Tracking control buttons (]) or ([)<br />

Specification<br />

Minimized noise on<br />

monitor screen<br />

1. PB the self-REC tape.<br />

2. Set to SLOW PB mode by pressing the SLOW key.<br />

3. Transmit the TEST(R/C code 47H).Or short the TP801<br />

on the main PWB once.<br />

4. Adjust the noise bar at the botton of monitor screen<br />

using TRACKING UP,DOWN key until it dissapear.<br />

5. Press the PB key to PB and during this time, press the<br />

PB/STILL for few times repeatedly and during STILL<br />

make sure no noise appear.<br />

Same with the SP, do the 1~5 items.(for LP )<br />

~. For LP, skew will appear at the above. (Only for <strong>VC</strong>-<br />

<strong>G401SM</strong>)<br />

ADJUSTMENT OF PAL SYSTEM FV (False<br />

Vertical Sync) OF STILL PICTURE<br />

Measuring<br />

instrument<br />

Mode<br />

Monitor Screen<br />

Playback still<br />

CH-2<br />

Video output<br />

TRIG INT CH-1,H:50 µsec/div<br />

V: 1V/div<br />

Cassette<br />

Self-recorded tape<br />

(SP/LP mode)<br />

Control Tracking control buttons (]) or ([)<br />

CH-1<br />

6.5H<br />

Specification<br />

No vertical jitter of picture<br />

V: 2V/div<br />

1. PB the self-REC tape.<br />

2. Press the PAUSE/STILL key and STILL the picture.<br />

3. As looking at the monitor, using the TRACKING UP+,<br />

DOWN− adjust till the perpendicular jitter dissapear.<br />

~ For the LP also, while PB the self-REC tape, for STILL,<br />

it is better to confirm that no perpendicular jitter appear.<br />