For the User<br />
1<br />
1. Operating instructions<br />
The installation and use of electrical appliances must be carried out with due caution in order to avoid the risk<br />
of fire, electric shock or injury. The equipment must only be used as described in these instructions. Any use<br />
outside of the manufacturer recommendations could lead to damage, fire, shock or injury.<br />
Before using the appliance the instructions should be read in their entirety and all appropriate handling of the<br />
equipment must be observed.<br />
These instructions should be kept safely and passed on to any future owner.<br />
In the event of any repair work, hand them to the qualified installer for his attention.<br />
1.1 Unit description<br />
The <strong>SK</strong> 04 (T) is suitable for heating rooms that are used infrequently, or to supplement an existing heating<br />
system. These units can be used as mobile free-standing units with the feet fitted, or alternatively as wall hanging<br />
units.<br />
The <strong>SK</strong> 04 (T) is supplied complete with a connecting cable.<br />
Only remove the packaging of the unit and accessories at the place of installation, taking note of the additional<br />
package.<br />
When unpacking, take care to ensure that no accessories remain behind in the packaging material.<br />
Unit design (see page 3)<br />
1 Thermostat knob<br />
Heat output switches<br />
3 Air outlet grille<br />
4 Fan air outlet grille (<strong>SK</strong> 04 T only)<br />
5 Recessed grips<br />
6 Foot<br />
7 Hanging bracket<br />
8 Unit rating label<br />
Range of use<br />
The use of the heater in bathrooms or similar damp environments is not permitted. The heater should not be<br />
used outdoors.<br />
The heat requirement of the room should be matched to the heat output of the unit. In very small rooms there is<br />
a risk of overheating, damage and fire.<br />
As a free standing appliance it can easily be used wherever heat is required (when used as a mobile free standing<br />
unit both feet must be fitted before switching on). The connection cable should not be covered with a<br />
carpet or mat, and should lie outside any ‘traffic area’ where it could be caught and the heater overturned.<br />
To prevent a tensed connecting cable (danger of stumble) do not position the appliance too distant from the<br />
shockproof socket.<br />
The use of an extension lead should be avoided. If an extension lead is used it should be of sufficient cable size<br />
for the full rating power of the heater. It should have a moulded plug and socket and sufficient preventative<br />
measures should be taken when using it.<br />
The equipment should always stand on a solid floor, on soft ground the appliance can tilt or the air grilles<br />
could be blocked.<br />
When transporting the appliance it should be held only by the recessed grips provided for this purpose (5), under<br />
no circumstances should it be carried by the mains electrical cable.<br />
Function<br />
To heat the air, ambient air entering the unit through the openings in the base of the unit is heated, this then<br />
flows out by means of natural convection, via the air outlet grille (3) at the top.<br />
In the case of the <strong>SK</strong> 04 (T), this process can be assisted by using the integral fan to push heat out through<br />
the separate outlet grille (4).<br />
1.2 Operation<br />
The operating controls are located within the right hand side section of the unit.<br />
Using the thermostat knob (1), the desired room temperature can be selected between approximately 5 °C and<br />
35 °C.<br />
The thermostat within the unit then keeps the ambient air constantly at this set value, by cycling the heating<br />
on and off for short periods.<br />
Using the switches (2), several different heat output levels can be selected (see following table). This gives increased<br />
economy by adapting to the prevailing heat requirement.