USER MANUAL<br />

ENGLISH<br />

VACUUM SYSTEM MOTOR FILTER CLEANING<br />

1. Drive the machine on a level fl oor.<br />

2. Disconnect the power supply cable (3) from the electrical mains.<br />

3. Remove the recovery water tank retaining plate (36).<br />

4. Open the recovery water tank.<br />

5. If necessary, drain the water from the tank in or<strong>de</strong>r to make the fi lter visible.<br />

6. Check that the pre-fi lter is clean. If necessary clean it with water and compressed air, then install it.<br />

7. Perform steps 1, 2, 3 and 4 in the reverse or<strong>de</strong>r.<br />

SOLUTION/CLEAN WATER FILTER CLEANING<br />

1. Drive the machine on a level fl oor.<br />

2. Disconnect the power supply cable (3) from the electrical mains.<br />

3. Close the solution tap (A, Fig. 5) un<strong>de</strong>r the machine, behind the right rear wheel. The tap (A) is closed when it is in the position<br />

(B) and it is open when it is in the position (C).<br />

4. Remove the transparent cover (D), then remove the fi lter strainer (E). Clean and install them on the support (F).<br />

NOTE<br />

The fi lter strainer (E) must be correctly positioned on the housing (G) of the support (F).<br />

5.<br />

Open the tap (A).<br />

A<br />

G<br />

E<br />

F<br />

E<br />

C<br />

B<br />

D<br />

Figure 5<br />

P100109<br />

9097056000(2)2009-06 A <strong>SCRUBTEC</strong> <strong>545E</strong> <strong>–</strong> <strong>553E</strong> 17