e guaranteed that the pump will run without problems and reach its<br />
full delivery rating.<br />
On receipt of delivery, immediately check the pumps for completeness,<br />
damage and compliance with the data on the delivery note. Defects and<br />
damage are to be notified at once to the transport company in order for<br />
any claim to be valid.<br />
2.0 DESCRIPTIONS FOR SCREWSPNDEL – AND CENTRIFUGAL PUMPS<br />
2.1 AREA OF USE<br />
2.1.1 SELF-PRIMING - CENTRIFUGAL PUMPS<br />
Pumps of the RS-series are used for all applications where self-priming<br />
is called for or in which the medium to be handled is susceptible to intensive<br />
gas evolution, for instance<br />
� in navigation as bilge or ballast pump,<br />
� in the building industry for building pit drainage and ground water<br />
lowering<br />
� Importantly: Consider max. tolerable particile size of pump<br />
� for pumping fuel oil, gasoline, benzene, solvents, etc.<br />
� for pumping pulp and cellulose, sewage, etc.<br />
2.1.2 NORMAL PRIMING – CENTRIFUGAL PUMPS<br />
These pumps are used for all applications where self-priming is not desired<br />
or not necessary because of the medium inflow.<br />
In such cases, the following pumps are employed, e.g.<br />
� volute casing block pumps RNWMo<br />