Flow velocities should lie in the ranges 0.5 to 1 m/s in the suction line<br />
and 2 to 3 m/s in the delivery line.<br />
Gate valves should be built in on either side of the pump, so that the<br />
pump can be dismantled from the system without draining the lines.<br />
If hoses are used, it should be ensured that these are not kinked and<br />
that their inside diameter is matched to that of the pump.<br />
Where rotary seals with sealing fluid feed are used or, in the case of<br />
pumps with heating or cooling arrangements, the auxiliary pipework<br />
should also be attached to the correspondingly marked connection<br />
points without applying any stress. Ensure that the auxiliary lines are<br />
flushed clean before connection.<br />
4.0 OPERATION ON THE PUMPS<br />
4.1.1 COMMISSIONING OF CENTRIFUGAL PUMPS<br />
After the specified work has been completed and checked, the pump<br />
can be commissioned.<br />
Before starting the driving machine, note the following items:<br />
● Bearing housings equipped with an oil-sight glass must be filled with<br />
oil up to the middle of the oil-sight glass. Suitable branded oils, e.g.<br />
of viscosity class 15W-40, should be used. Bearing ousings without<br />
oil-sight glass have already been provided with a grease fill in the<br />
workshop.<br />
● If cooling is provided, the cooling water must be turned on and the<br />
flow must be checked.<br />
● Fill the pump completely with the medium to be pumped, open the<br />
shut-off valve on the suction side completely and the shut-off valve on<br />
the pressure side by half.<br />
● If installed, turn on the sealing and flushing liquid supplies. Fully open<br />
the throttles.<br />
BETRIEBSANLEITUNG<br />
36 RUSCH PUMPENFABRIK GMBH