pump while smaller particles cause continuous wear to an extent that<br />

depends on their size, hardness, geometry, and volumetric concentration.<br />

In order to protect the pump against such particles, a fine mesh suction<br />

filter of the largest possible size should be provided. The dimensions of<br />

the filter should be designed such that, with clean filter elements, the<br />

pressure loss does not exceed 1 mWC. The mesh size should be 0.1 to<br />

0.5 mm.<br />

4.3.4 CONSERVATION AND STORAGE<br />

If the pump is not used for long periods, is put into storage or, together<br />

with the pipework, is filled with liquid and put under pressure to test for<br />

leaks, it must be suitably conserved to prevent rust formation.<br />

Attention! If conservation is not expressly specified at the time<br />

of ordering, it must be carried out subsequently.<br />