pump while smaller particles cause continuous wear to an extent that<br />
depends on their size, hardness, geometry, and volumetric concentration.<br />
In order to protect the pump against such particles, a fine mesh suction<br />
filter of the largest possible size should be provided. The dimensions of<br />
the filter should be designed such that, with clean filter elements, the<br />
pressure loss does not exceed 1 mWC. The mesh size should be 0.1 to<br />
0.5 mm.<br />
4.3.4 CONSERVATION AND STORAGE<br />
If the pump is not used for long periods, is put into storage or, together<br />
with the pipework, is filled with liquid and put under pressure to test for<br />
leaks, it must be suitably conserved to prevent rust formation.<br />
Attention! If conservation is not expressly specified at the time<br />
of ordering, it must be carried out subsequently.<br />