13.07.2015 Aufrufe

1 - 3D Air Sales Ltd.

1 - 3D Air Sales Ltd.

1 - 3D Air Sales Ltd.

MEHR ANZEIGEN
WENIGER ANZEIGEN

Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.

YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.

Please remember!You cannot restart the unit immediately after you havestopped it.(RUN light is on)Notoperating?Restarting has been blocked for 3 minutes after you have stopped orafter switching off the power during operation, to protect the unit.Please wait forthree minutes.The three-minute protection timer in the microcomputer automaticallystarts up again.<strong>Air</strong> is not blown out when starting the HEATING operation.RUN light blinks slowly(1.5 sec ON, 0.5 sec OFF)<strong>Air</strong> is not blown out for 5 to 10 min. at HEATING operation.RUN light blinks slowly(1.5 sec ON, 0.5 sec OFF)<strong>Air</strong> is not blown out when starting the DRY operation.Some steam escapes during COOL operation.There is a slight smell.You hear a slight gurgling sound.(RUN light is on)<strong>Air</strong> flow has stopped to prevent blowing out of cold air until the indoorheat exchanger has warmed up. (2 to 5 min.) (HOT KEEP)When outdoor temperature is low and humidity is high, the unit sometimesperforms defrosting automatically. Please wait. During defrosting,water or steam may escape from the outdoor unit.The indoor fan may stop to prevent re-evaporation of dehumifiedmoisture and to save energy.This may occur if the room's temperature and humidity are very high.It disappears as soon as the temperature and humidity decrease.<strong>Air</strong> blown out during operation may smell. This is caused by tobaccoor cosmetics sticking to the unit.This is caused by refrigerating liquid moving within the unit.You hear a slight cracking sound.After a power cut, you cannot re-start, even if power has been restored,unless you have the power blackout auto restart function.Remote control signals are not received.This is caused by heat expansion or contraction.The memory circuit of the microcomputer has been wiped out. Use theremote control to start the operation again.Remote control signals may not be received if the signal receiver onthe air conditioner is exposed to direct sunlight or other bright light.If so, cut out the sunlight or reduce the other light.Moisture may form on the air outlet grilles.FAN operation will be performed even if COOL, DRY, orHEAT have been selected.Whistling noise is heard from the outdoor unit.Sometimes a “Shooooo” sound might come for a short timefrom the unit that is turned off.If the unit is operated for a long time in high humidity, moisture mayform on the air outlet grilles and start dripping.If one unit is operating in COOL mode while another is in operating inHEAT or any other different operation mode, FAN mode operationwill be implemented. Individual operation modes need to be matched.The noise means that the revolution speed is picking up on the compressor.This is the sound when operation of another indoor unit is stopped.– 18 –

Hurra! Ihre Datei wurde hochgeladen und ist bereit für die Veröffentlichung.

Erfolgreich gespeichert!

Leider ist etwas schief gelaufen!