44<br />

Annexure to Directors’ <strong>Report</strong><br />

Form a<br />

DIScLOSURE Of PARTIcULARS wITH RESPEcT TO cONSERVATION Of ENERGY<br />

A. POwER AND fUEL cONSUMPTION<br />

1. ELECTRICITY<br />

ballarpur industries limited | annual report 2010–11<br />

current year previous year<br />

2010-<strong>2011</strong> 2009-2010<br />

paper paper<br />

(A) Purchased<br />

UNITS 000 KWH 223,973 216,806<br />

TOTAL AMOUNT Rs.Lacs 9,922 8,148<br />

RATE / UNIT<br />

(B) Own Generation<br />

(i)Through Generator - D.OIL/LSHS/HSD<br />

Rs. 4.43 3.76<br />

UNITS 000 KWH - -<br />

Units per litre of D.oiL/LSHS/HSD KWH - -<br />

Cost per unit<br />

(ii)Through Steam Turbine / Generator<br />

Rs.<br />

UNITS 000 KWH - -<br />

Units of Power per mt of coal KWH - -<br />

Cost per unit Rs. - -<br />

2 COAL<br />

(Quality used in boilers-GRADES : B,C,D, etc.)<br />

QUANTITY M.T. 37,608 40,359<br />

TOTAL COST Rs.Lacs 1,080 931<br />

Average rate Rs/M.T 2,872 2,308<br />

3 FURNACE OIL/LSHS/LDO/RFO<br />

QUANTITY K.L. 6,417 6,667<br />

TOTAL COST Rs.Lacs 1,891 1,667<br />

Average Rate Rs/K.L 29,468 24,998<br />

4 OTHERS / INTERNAL GENERATION ETC.<br />

(BLACK LIQUOR SOLIDS FIRED, WASTE HEAT RECOVERY, LPG )<br />

QUANITITY ( COAL EQUIVALENT ) M.T. - -<br />

TOTAL COST Rs.Lacs - -<br />

Average Rate<br />

B. cONSUMPTION PER UNIT Of PRODUcTION<br />

Rs/M.T - -<br />

Electricity coal furnace Oil Others/Internal Generation<br />

(KWH/tonne) (m.t./ tonne) (K.l./ tonne) (m.t./tonne)<br />

current year previous year current year previous year current year previous year current year previous year<br />

2010-11 2009-10 2010-11 2009-10 2010-11 2009-10 2010-11 2009-10<br />

Paper 1,118 1,051 0.188 0.196 0.032 0.032 0.000 0.000<br />

ENERGY CONSERVATION<br />

MEASURES TAKEN, RESULTS<br />

ACHIEVED & PLANS FOR THE<br />

FUTURE, SPECIFIC MEASURES<br />

TAKEN DURING THE YEAR<br />

2010-<strong>2011</strong>:<br />

All business Units continued their efforts to<br />

improve energy usages efficiency and increase<br />

contributions from renewable sources of<br />

energy. Innovative ways and new technologies<br />

were constantly explored to reduce energy<br />

consumption. Some of the measures adopted<br />

across the Company were:-<br />

a) unit shree Gopal:<br />

Reduced power consumption by<br />

1.<br />

installing VFDs at :<br />

Hydra treated pump Speciality Paper<br />

a.<br />

Machines.<br />

Water supply pump to Speciality<br />

b.<br />

Paper Machines.