ISOPRO® Type IPT - Spanelas
ISOPRO® Type IPT - Spanelas
ISOPRO® Type IPT - Spanelas
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
8<br />
ISOPRO ®<br />
Building physics – Fire protection DIN 4109<br />
Fire-resistance class F 30<br />
All ISOPRO ® elements are categorised as fire protection class F30. The requirements to be met for the complete construction<br />
are illustrated in the following diagrams:<br />
F30 - wall area construction F30 - door area construction<br />
mineral-based mineral-based plaster plaster<br />
screeding / screeding plastering / plastering<br />
ISOPRO element ISOPRO element<br />
screeding / screeding plastering / plastering<br />
ISOPRO element ISOPRO element<br />
mineral-based mineral-based plaster plaster mineral-based mineral-based plaster plaster<br />
Fire-resistance class F 90<br />
All ISOPRO ® elements are also supplied to fire-resistance class F90, meeting the technical requirements for fire protection<br />
of balconies etc.<br />
The designation F90 is added to the element identification e.g. ISOPRO ® <strong>IPT</strong> 55 cv 30 F90.<br />
A1 material<br />
non-flammable<br />
The ISOPRO ® elements are fitted with fire protection plates attached to the top side and the under side.<br />
The construction can be seen in the sketch of the system below.<br />
detail 1<br />
detail 1<br />
A1 material<br />
non-flammable<br />
It is self-evident that to meet the requirements of the fire-resistance class F90, all other adjacent construction elements<br />
must also satisfy these requirements. For constructions with selected-point connections it is necessary to ensure that the<br />
intermediate insulation used also meets the fire-resistance requirements.<br />
www.h-bau.com<br />
100<br />
15<br />
15<br />
8<br />
F90 fire fire protection slab<br />
F90 fire fire protection slab