6<br />
27.5<br />
35<br />
7<br />
GDSB211<br />
27.5<br />
52<br />
M3<br />
Ø 22.5<br />
Type GDSB 211<br />
plug-in connector DIN EN 175301-803 (DIN 43650-A)<br />
with integral rectifier GDSB 211<br />
max. 230 VAC ±10% / 2 ADC<br />
order No: 314 1051<br />
Plug-in connectors<br />
2-pole plug-in connectors with PE line connection<br />
Plug-in connectors are detachable connections specially<br />
designed for electromagnetic devices. The 2-pole<br />
versions are used to connect single-direction linear<br />
solenoids and electromagnetic clamps. The cable<br />
outlet can be rotated through 4 x 90° by inserting<br />
the contact carrier accordingly.<br />
The plug-in connector is secured with a machine<br />
screw (supplied) after being plugged onto the device<br />
pins. This guarantees an effective seal between the<br />
plug-in connectors with rectifier<br />
34<br />
39<br />
7<br />
GDSBV211<br />
34<br />
18<br />
M3<br />
72<br />
Type GDSBV 211<br />
plug-in connector DIN EN 175301-803 (DIN 43650-A),<br />
protective varistor with integral rectifier GDSBV 211<br />
max. 230 VAC ±10% / 4 ADC<br />
order No: 314 1049<br />
two and prevents the connector from becoming<br />
accidentally detached.<br />
A screwed cable gland, thread size Pg 11 (GD209: Pg 9),<br />
serves to seal the cable entry.<br />
The contact elements are suitable for connecting wire<br />
cross-sections up to max. 1.5 mm 2 .<br />
Air clearance and leakage path to VDE 0110.<br />
Insulation class C.<br />
When plugged in and secured, the connection meets the<br />
requirements of class of protection IP 65 to IEC 60529.<br />
www.kendrionmt.com<br />
CE<br />
These components are not electronic or electrical<br />
devices in the meaning of the Machinery<br />
Directive 98/37/EC, but instead are merely<br />
intended for incorporation in other machines or<br />
systems, and are not for use by end-users. The user<br />
must guarantee that his end product complies with<br />
the appropriate directives.<br />
Low Voltage Directive 73/23/EEC.<br />
We declare compliance with the following standards:<br />
HD625.1 S1 (1996)<br />
IEC 60529 (1991<br />
The products are components in the meaning of the<br />
Machinery Directive 98/37/EC. According to<br />
this directive, such products incorporated in a<br />
machine may not be operated until said machine’s<br />
conformity with the EC directive has been established.<br />
A manufacturer’s declaration can be obtained on<br />
request.<br />
Permissible continuous maximum temperature<br />
90°C; the connection can withstand temperatures of<br />
up to 120°C briefly without suffering any damage.<br />
When using the GDSB 211 or GDSBV 211 plug-in<br />
connector with integral rectifier, the plug-in connector<br />
can be used as a direct connecting element between<br />
an AC mains system and a DC consumer.<br />
Four silicon diodes form a bridge circuit. A varistor<br />
connected in parallel on the AC side protects the<br />
bridge rectifier against voltage spikes from the<br />
mains.