DRX-2<br />

2<br />

DRX-2<br />

■ TO SERVICE PERSONNEL<br />

1. Critical Components Information<br />

Components having special characteristics are marked s<br />

and must be replaced with parts having specifications equal<br />

to those originally installed.<br />

2. Leakage Current Measurement (For 120V Models Only)<br />

When <strong>service</strong> has been completed, it is imperative to verify<br />

that all exposed conductive surfaces are properly insulated<br />

from supply circuits.<br />

● Meter impedance should be equivalent to 1500 ohm shunted<br />

by 0.15µF.<br />

WALL<br />

OUTLET<br />

WARNING: CHEMICAL CONTENT NOTICE!<br />

EQUIPMENT<br />

UNDER TEST<br />

INSULATING<br />

TABLE<br />

● Leakage current must not exceed 0.5mA.<br />

AC LEAKAGE<br />

TESTER OR<br />

EQUIVALENT<br />

● Be sure to test for leakage with the AC plug in both polarities.<br />

THE DVD RECORDER SHOULD NOT BE ADJUSTED OR REPAIRED BY ANYONE EXCEPT PROPERLY QUALIFIED<br />

SERVICE PERSONNEL.<br />

CAUTION<br />

1001 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 125mA, 250V FUSE.<br />

1300 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 2.5A, 250V FUSE.<br />

1303 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 250V FUSE.<br />

1304 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 4.0A, 250V FUSE.<br />

1306 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 125mA, 250V FUSE.<br />

1307 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 250V FUSE.<br />

1308 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 500mA, 250V FUSE.<br />

1309 (ANALOG P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 800mA, 250V FUSE.<br />

1505 (DIGITAL P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE.<br />

1506 (DIGITAL P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE.<br />

1507 (DIGITAL P.C.B.): FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 1.0A, 125V FUSE.<br />

CAUTION<br />

1001 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 125mA, 250V FUSE.<br />

1300 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 2.5A, 250V FUSE.<br />

1303 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 1.0A, 250V FUSE.<br />

1304 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 4.0A, 250V FUSE.<br />

1306 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 125mA, 250V FUSE.<br />

1307 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 1.0A, 250V FUSE.<br />

1308 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 500mA, 250V FUSE.<br />

1309 (ANALOG P.C.B.): REPLACE WITH SAME TYPE 800mA, 250V FUSE.<br />

1505 (DIGITAL P.C.B.): REPLACE WITH SAME TYPE 1.0A, 125V FUSE.<br />

1506 (DIGITAL P.C.B.): REPLACE WITH SAME TYPE 1.0A, 125V FUSE.<br />

1507 (DIGITAL P.C.B.): REPLACE WITH SAME TYPE 1.0A, 125V FUSE.<br />

ATTENTION<br />

1001 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 125mA, 250V.<br />

1300 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 2.5A, 250V.<br />

1303 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 250V.<br />

1304 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 4.0A, 250V.<br />

1306 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 125mA, 250V.<br />

1307 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 250V.<br />

1308 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 500mA, 250V.<br />

1309 (ANALOG P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 800mA, 250V.<br />

1505 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 125V.<br />

1506 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 125V.<br />

1507 (DIGITAL P.C.B.): UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 1.0A, 125V.<br />

The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and /or plastic<br />

(where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency<br />

(and possibly other entities) to cause cancer and/or birth defects or other reproductive harm.<br />

DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-<br />

SON WHATSOEVER!<br />

Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose<br />

eyes to solder/flux vapor!<br />

If you come in contact with solder or components located inside the enclosure of this product, wash your hands before<br />

handling food.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!