DRX-2<br />

36<br />

DRX-2<br />

Nucleus Name DS_PSCAN_TestImageColourSettingsGet<br />

Nucleus Number 805<br />

Description Get the colour settings of the hatch- or the frame- field.<br />

Technical - Initialise IIC.<br />

- Read the colour settings from the DENC through IIC.<br />

Execution Time Less than 1 second.<br />

User Input None<br />

Error Number Description<br />

80500 Getting the colour-settings succeeded<br />

80501 The progressive scan DENC-IC was not accessible through IIC<br />

80502 Unable to get colour<br />

80503 No chip was expected<br />

Example DS:> 805<br />

080500: Colour Y Cr Cb values: 0xD2 0x92 0x10<br />

Test OK @<br />

Nucleus Name DS_PSCAN_Routing<br />

Nucleus Number 806<br />

Description Route a video signal from the host processor through the progressive scan ICs to the pro<br />

gressive scan output of the set.<br />

Note: to route the progressive scan to the output of the set, first call nucleus 1112 with pa<br />

rameter 0 (video routing on analog board).<br />

Technical - Initialise the PIO pins of the chrysalis<br />

- Initialise IIC<br />

- Reset the DENC<br />

- Enable the 27Mhz clock<br />

- Send all settings to the DENC through IIC.<br />

Execution Time Less than 1 second.<br />

User Input None<br />

Error Number Description<br />

80600 Routing path is created successfully.<br />

80601 Unable to initialise the Chrysalis.<br />

80602 Unable to access DENC<br />

80603 Unable to access deinterlacer.<br />

80604 Wrong chips were expected.<br />

Example DS:> 806<br />

080600:<br />

Test OK @