WGxx <strong>Arbitrary</strong> <strong>Waveform</strong> <strong>Generator</strong> Front Panel Operation<br />
Special Functions<br />
This menu allows the selection of one of the two special functions ‘Freq Count'<br />
(frequency measurement of an external signal) or ‘SweepMode' by pressing<br />
button 1 or 3 .<br />
F r e q S w e e p<br />
C o u n t M o d e<br />
Fig.20: Special function menu<br />
Measurement of External Frequency<br />
Sweep Mode<br />
The frequency of an external signal fed into the FREQ IN input of the<br />
instrument can be measured in the range [0.1Hz ...10MHz]. There, the<br />
amplitude of the input signal has to be within the interval [0.2Vpp ... 50Vpp].<br />
f = 1 2 3 , 4 k H z<br />
. T = 8 , 1 0 3 u S<br />
Fig.21: Frequency measurement of external signal<br />
In addition, also the period of the actual measurement value is given.<br />
This function is only available for arbitrary waveform generation.<br />
The first line of the display indicates the sweep time (resolution 100ms). Within<br />
this time interval the individual frequency values are updated by a 20ms clock<br />
(i.e., for 0.1s sweep time five different discreet frequencies between start and<br />
stop frequency are generated).<br />
S w e e p : t = 5 , 3 s<br />
1 0 k 0 2 0 k 0 l o g<br />
Fig.22: Sweep mode<br />
The left value displayed in the second LCD line gives the starting frequency,<br />
the value displayed in the center of the LCD gives the stop frequency of the<br />
sweep cycle. By pressing button 1 (or 2 , respectively) one of the three<br />
memory cells of the frequency memory can be selected to define the start<br />
frequency (or the stop frequency, respectively) of the sweep cycle. It should be<br />
noted that also a sweep cycle with decreasing frequency ramp can be realized<br />
if start frequency > stop frequency has been chosen.<br />
To change the three memory values for start and stop frequency it is required<br />
to overwrite the memory cells of the frequency adjustment (see section<br />
Frequency).<br />
With button 3 the sweep-type can be modified.<br />
Here the modes linear, logarithmic or exponential are available.<br />