21.03.2013 Views

Arbitrary Waveform Generator - Produktinfo.conrad.com

Arbitrary Waveform Generator - Produktinfo.conrad.com

Arbitrary Waveform Generator - Produktinfo.conrad.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WGxx <strong>Arbitrary</strong> <strong>Waveform</strong> <strong>Generator</strong> Front Panel Operation<br />

Special Functions<br />

This menu allows the selection of one of the two special functions ‘Freq Count'<br />

(frequency measurement of an external signal) or ‘SweepMode' by pressing<br />

button 1 or 3 .<br />

F r e q S w e e p<br />

C o u n t M o d e<br />

Fig.20: Special function menu<br />

Measurement of External Frequency<br />

Sweep Mode<br />

The frequency of an external signal fed into the FREQ IN input of the<br />

instrument can be measured in the range [0.1Hz ...10MHz]. There, the<br />

amplitude of the input signal has to be within the interval [0.2Vpp ... 50Vpp].<br />

f = 1 2 3 , 4 k H z<br />

. T = 8 , 1 0 3 u S<br />

Fig.21: Frequency measurement of external signal<br />

In addition, also the period of the actual measurement value is given.<br />

This function is only available for arbitrary waveform generation.<br />

The first line of the display indicates the sweep time (resolution 100ms). Within<br />

this time interval the individual frequency values are updated by a 20ms clock<br />

(i.e., for 0.1s sweep time five different discreet frequencies between start and<br />

stop frequency are generated).<br />

S w e e p : t = 5 , 3 s<br />

1 0 k 0 2 0 k 0 l o g<br />

Fig.22: Sweep mode<br />

The left value displayed in the second LCD line gives the starting frequency,<br />

the value displayed in the center of the LCD gives the stop frequency of the<br />

sweep cycle. By pressing button 1 (or 2 , respectively) one of the three<br />

memory cells of the frequency memory can be selected to define the start<br />

frequency (or the stop frequency, respectively) of the sweep cycle. It should be<br />

noted that also a sweep cycle with decreasing frequency ramp can be realized<br />

if start frequency > stop frequency has been chosen.<br />

To change the three memory values for start and stop frequency it is required<br />

to overwrite the memory cells of the frequency adjustment (see section<br />

Frequency).<br />

With button 3 the sweep-type can be modified.<br />

Here the modes linear, logarithmic or exponential are available.<br />

15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!