Bonding the NIU<br />

Bonding the NIU is similar to bonding a standard coax installation (see Section 7 - Attaching to the ground<br />

block). You should attach the NIU to the wall as closely as possible to the electrical meter. The bonding wire is<br />

attached to a point within the NIU enclosure. Specific bonding points will vary with each make of NIU, so please<br />

consult the manufacturer’s instructions. In all cases, the bonding wire should be as straight as possible and run<br />

horizontally to the attachment point at the meter.<br />

The preferred bonding method is to attach the NIU’s bond to the electrical meter ground wire with a wire not less<br />

than 14 AWG in size. For recommendations regarding ground wires sizes, please refer to the National Electric<br />

Code (NEC 820-40) or your local building code.<br />

If bonding the NIU to the meter is not possible, you may bond to an<br />

exterior metal cold water pipe running into the earth. As a last resort,<br />

you may drive an 8’ ground rod into the earth and attach the bonding<br />

wire to that, but you will need to attach all of the grounds of the residence<br />

to that rod.<br />

Connectorize the Cable and Attach it to the NIU<br />

Once the ground is attached, cut the coax so that you have a sufficient<br />

amount to comfortably reach the connection within the NIU plus about<br />

another 1’ (30 cm), similar to the pedestal attachment (see page 6.4).<br />

Connectorize the cable (see page 9.9) and attach it to the NIU. If the<br />

cable is entering from above, form a small drip loop below the connection<br />

of the cable and the NIU. This loop will be useful if you have to<br />

reconnectorize the cable in the future.<br />

Attaching to the Ground Block per NEC 830 8.2<br />

Connecting to the Buried Drop