23.03.2013 Views

Static and Dynamic Draft in HYPACK.fm

Static and Dynamic Draft in HYPACK.fm

Static and Dynamic Draft in HYPACK.fm

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IN <strong>HYPACK</strong>® HARDWARE<br />

20<br />

FIGURE 32. <strong>Static</strong> <strong>Draft</strong> as Vertical Offset of the Echosounder<br />

• For the Echosounder: The echosounder will be outputt<strong>in</strong>g<br />

the Depth Below Transducder (18.5m), so we need to enter<br />

the <strong>Static</strong> <strong>Draft</strong> value as the Vertical Offset for the<br />

Echosounder device <strong>in</strong> <strong>HYPACK</strong>® HARDWARE.<br />

• For the DRAFTTABLE.DLL: There are no offsets associated<br />

with the DRAFTTABLE.DLL. After select<strong>in</strong>g the driver, click the Setup button to access<br />

the table entries <strong>and</strong> driver sett<strong>in</strong>gs.<br />

FIGURE 33. <strong>Draft</strong>Table Driver Setup<br />

My sett<strong>in</strong>gs (Figure 33) show that at 5kts, we should have an <strong>in</strong>terpolated <strong>Dynamic</strong> <strong>Draft</strong><br />

value of 0.5m. I have elected to use only a s<strong>in</strong>gle Speed versus <strong>Dynamic</strong> <strong>Draft</strong> graph <strong>in</strong> my<br />

examples.<br />

FIGURE 34. Limit<strong>in</strong>g the Update Rate