Models-and-dimensions_2010-2011_INT
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
AC 402 180*<br />
Stainless steel<br />
Filter module<br />
Air extraction/recirculation with remote<br />
fan unit AR 400/401<br />
Installation accessories<br />
AD 704 044<br />
Air collector box DN 200<br />
cylindrical duct<br />
2 x DN 150 cylindrical duct air intake.<br />
1-2 x DN 200 cylindrical duct air outlet.<br />
AD 854 044<br />
Air collector box DN 150 flat duct<br />
2 x DN 150 flat duct air intake.<br />
1 x DN 200 flat duct air outlet.<br />
Special accessories<br />
KF 273 198<br />
Activated charcoal air filter for<br />
retrofitting AH 273/198<br />
* Available 4. quarter <strong>2010</strong><br />
146 Ventilation appliances<br />
Vario ceiling ventilation<br />
AC 402<br />
– Discreet integration into the<br />
architecture of the kitchen<br />
– Flexible by dimension, performance<br />
<strong>and</strong> ventilation mode<br />
– Room ventilation<br />
– Modular ceiling ventilation, which<br />
can be configurated individually by<br />
separat components such as filter<br />
module, control modules <strong>and</strong> light<br />
module<br />
– Individual configuration of<br />
unobstructed airflow of remote fan<br />
unit from 950 – 2800 m³/h<br />
– Highly efficient patented rim<br />
extraction<br />
– Planed <strong>and</strong> easy to clean underside<br />
with covered filters<br />
Output<br />
Maximum air output in combination<br />
with remote fan units s. table remote<br />
fan units on page 190/191.<br />
Sound power level depends on the<br />
built-in situation.<br />
Features<br />
Rim extraction filter, dishwasher-safe.<br />
Installation frame for thread rods (rods<br />
not included).<br />
Connection piece DN 150 cylindrical.<br />
Planning notes<br />
The ceiling ventilation has to be<br />
h<strong>and</strong>led as a room ventilation when<br />
distance to cooktop is larger than<br />
120 cm since the direct capture of<br />
vapours will be limited. The needed<br />
airflow is given by an air exchange rate<br />
of 10 to 12 times the room volume.<br />
Please refer to page 148/149 for<br />
recommended configurations of ceiling<br />
ventilations <strong>and</strong> remote fan units <strong>and</strong><br />
the resulting <strong>dimensions</strong>.<br />
Air extraction in combination with<br />
remote fan unit AR 400/401. For<br />
recirculation mode 1 activated carbon<br />
filter KF 273 198 per filter module is<br />
needed.<br />
Max. 2 filter modules to be connected<br />
to 1 AR 400/401 130. Max. 3 filter<br />
modules to be connected to<br />
AR 400/401 140.<br />
When installing remote fan unit AR 400<br />
within the ceiling or furniture block it<br />
must remain accessible through the<br />
ceiling cutout or another maintenance<br />
access.<br />
To be installed in st<strong>and</strong>ard ceiling or<br />
furniture cutout which will be covered<br />
by module frames with 0.8 mm<br />
thickness.<br />
When installing a ventilation hood with<br />
air extraction mode or recirculation<br />
outlet in another area of room air (e.g.<br />
cellar) <strong>and</strong> a chimney-vented fireplace,<br />
the hood’s power supply line needs a<br />
suitable safety switch.<br />
For maximum duct lengths use<br />
Gaggenau flat rectangular ducts AD 8<br />
or Naber-System Compair flow. Other<br />
flat ducts are not permitted!<br />
Please ensure when installing the<br />
exhaust air ducting that no sharp<br />
bends are caused <strong>and</strong> that the<br />
cross-section of the ducting is not<br />
constricted in any way.<br />
For downdraft configurations with<br />
maximum lengths of exhaust air ducts<br />
go to Rodun at www.gaggenau.com.<br />
AC 482 180*<br />
Stainless steel<br />
Control module with light<br />
For controlling remote fan units<br />
AR 400/401<br />
AC 462 180*<br />
Stainless steel<br />
Control module without light<br />
For controlling remote fan units<br />
AR 400/401<br />
Special accessories<br />
AA 090 100<br />
Circuit amplifier for connecting two<br />
remote fan units<br />
* Available 4. quarter <strong>2010</strong><br />
Vario ceiling ventilation<br />
AC 482/AC 462<br />
– Control module of ceiling<br />
ventilation<br />
– Individual configuration of<br />
unobstructed airflow of remote fan<br />
unit from 950 – 2800 m³/h<br />
– Individual integration of light<br />
elements into the configuration of<br />
the ceiling ventilation<br />
Output<br />
Maximum air output in combination<br />
with remote fan units s. table remote<br />
fan units on page 190/191.<br />
Features<br />
7-key infrared remote control, backup<br />
keys for operation also on the control<br />
module.<br />
3 electronically controlled output<br />
levels.<br />
Intensive mode.<br />
Run-on function.<br />
Acoustic grease filter saturation<br />
indicator.<br />
Dimmable halogen Soft-Light 2 x 20 W<br />
(only at AC 482).<br />
Planning notes<br />
Fixing at the filter module.<br />
Max. 2 AR 400/401 to be controlled<br />
with one control module.<br />
One amplifier AA 090 100 is needed<br />
for connecting two remote fan units.<br />
Max. 2 additional light modules<br />
connected to one control module with<br />
light.<br />
Fit one socket within the area of<br />
control module, two sockets when<br />
using amplifier AA 090 100.<br />
When installing a ventilation hood with<br />
air extraction mode or recirculation<br />
outlet in another area of room air (e.g.<br />
cellar) <strong>and</strong> a chimney-vented fireplace,<br />
the hood’s power supply line needs a<br />
suitable safety switch.<br />
Connection<br />
Total connected load<br />
max. 365 – 1200 W.<br />
Connecting cable 1.3 m with plug.