(j) Toe-boards and end toe-boards shall be suitably fixed to all<br />
working platforms and shall have a minimum height of 200mm (Third<br />
Schedule to the CSSR). They should be placed inside the standards.<br />
(See Figures 1 and 2 for details)<br />
(k) Space between platform and wall of a building or structure should be<br />
as small as practicable. Guard-rails should be provided if there is a<br />
risk of falling from height.<br />
(l) Working platforms should be cleared of debris like concrete waste.<br />
(m) Working platforms should not be overloaded and the load should be<br />
evenly distributed.<br />
(n) No shock loading on the platforms should be allowed.<br />
(o) The scaffold should be effectively braced to ensure stability of the<br />
whole structure.<br />
(p) The bracings should extend from the base to the top of the<br />
scaffold.<br />
(q) If electrical equipment such as power hand tools or electric<br />
installation including lighting is to be used on the scaffold, they should<br />
be of proper design and installation to prevent electrical hazard.<br />
(r) Where a scaffold is erected adjacent to a road or pathway,<br />
overlay or screen nets must be erected to envelop the scaffold for the<br />
protection of person or vehicular traffic against falling objects.<br />
(s) Safe access to and egress from place of work should be<br />
provided for the scaffolders and the users of the scaffold. One<br />
way of providing a safe access to and egress from a scaffold is to<br />
provide a safe gangway between the existing building/structure and<br />
the scaffold. Access and egress provided should be used and no<br />
climbing along the standards/ledgers of the scaffold should be<br />
allowed.