<strong>CODE</strong> <strong>OF</strong> <strong>PRACTICE</strong> <strong>FOR</strong> <strong>METAL</strong> <strong>SCAFFOLDING</strong> <strong>SAFETY</strong><br />

(iv) Gangways and working platforms should preferably be horizontal but<br />

may slope at an inclination of up to 1 vertical to 4 horizontal without<br />

stepping laths. At slopes steeper than this they should be provided<br />

with stepping laths to provide a firm foothold.<br />

(v) Ladders or other suitable means should be provided so as to<br />

enable workers to gain access to and egress from one platform to<br />

another.<br />

(e) Stair/ladder access to and in scaffolds<br />

Stair and ladder towers should be constructed with one side common with<br />

the outside of the scaffold. Bracings should be fixed to the remaining<br />

sides except in the bays through which access and egress is required.<br />

The superimposed loading adopted in calculations should be not less than<br />

2kN/m 2 for all landings and stairs in stair towers and ladder towers.<br />

(i) Every sloping ladder should stand on a firm and level base and be<br />

supported only by the stiles. The stiles should be securely fixed to the<br />

scaffold by lashings or by other attachments at the top.<br />

(ii) Ladder should be set at an angle of 4 vertical to 1 horizontal.<br />

(iii) Ladders should project at least 1.05m above the top landing with the<br />

landing rung level with or slightly above the level of the landing.<br />

Ladders should not be extended by lashing two lengths together.<br />

(iv) The vertical distance between two successive landings should not<br />

exceed 9m. The landings should be provided with access holes for<br />

the user which should not exceed 500mm in width and should be as<br />

small as practicable in the other direction.<br />

(v) Where practicable, the ladder access to the scaffold should be with<br />

its own ladder tower fixed to the outside of the main scaffold.<br />

(vi) Both ladder towers and stair towers should be fully decked at the<br />

landings. Toe-boards should be provided at the landings.