Figure 3.10<br />
PV field<br />
Subfield<br />
switchboards<br />
Q1-1<br />
Q1-2<br />
Q1-3<br />
Q1-4<br />
Disconnection of the inverter must be possible both on<br />
the DC side as well as on the AC side, so that maintenance<br />
is allowed by excluding both the supply sources,<br />
that is PV generator and grid.<br />
String paralleling switchboard<br />
String paralleling switchboard<br />
String paralleling switchboard<br />
String paralleling switchboard<br />
To the switchboard Q7 - 1<br />
To the switchboard Q6 - 1<br />
To the switchboard Q5 - 1<br />
To the switchboard Q4 - 1<br />
To the switchboard Q3 - 1<br />
To the switchboard Q2 - 1<br />
To the switchboard Q7 - 2<br />
To the switchboard Q6 - 2<br />
To the switchboard Q5 - 2<br />
To the switchboard Q4 - 2<br />
To the switchboard Q3 - 2<br />
To the switchboard Q2 - 2<br />
To the switchboard Q7 - 3<br />
To the switchboard Q6 - 3<br />
To the switchboard Q5 - 3<br />
To the switchboard Q4 - 3<br />
To the switchboard Q3 - 3<br />
To the switchboard Q2 - 3<br />
To the switchboard Q7 - 4<br />
To the switchboard Q6 - 4<br />
To the switchboard Q5 - 4<br />
To the switchboard Q4 - 4<br />
To the switchboard Q3 - 4<br />
To the switchboard Q2 - 4<br />
Field<br />
switchboards<br />
Inverter<br />
Inverter<br />
Inverter<br />
Inverter<br />
Inverter paralleling<br />
switchboard<br />
Besides, as shown in Figure 3.10, it is advisable to install<br />
a disconnecting device on each string, so that verification<br />
and maintenance operations on each string are<br />
possible without putting out of service the other parts<br />
of the plant.<br />