Answer Wood Stove - Lopi
Answer Wood Stove - Lopi
Answer Wood Stove - Lopi
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12 <strong>Stove</strong> Installation (for qualified installers only)<br />
Chimney Termination Requirements<br />
Must have an approved cap (to prevent water from entering).<br />
Must not be located where it will become plugged by snow or other material.<br />
Must terminate at least 3' (914mm) above the roof and at least 2' (610mm) above any portion of the<br />
roof within 10' (3.04M) - see Figure 5.<br />
Outside Air Requirements<br />
Figure 5<br />
Required for mobile homes & in certain localities (check with building officials).<br />
Must not be drawn from an enclosed space (garage, unventilated crawl space). May be drawn from<br />
ventilated crawl space (a) or exterior of home (d). Must have suitable rodent/debris screen and rain<br />
protection (hood).<br />
Requires the optional outside air kit (sku 99200139 – see (c) and (e) below), air boot (for legs), or<br />
pedestal (b).<br />
Air duct maximum length is 15’ (4.57M) with a minimum cross section of 16 square inches<br />
(10404mm) or 6’ (1.82M) with a minimum cross section of 7 square inches (4489mm).<br />
a<br />
Min. 3’ (914mm)<br />
Min. 3’ (914mm)<br />
<br />
<br />
<br />
10’ (3.04M)<br />
<br />
Min. 2’ (610mm)<br />
<br />
<br />
<br />
c<br />
b<br />
d<br />
Min. 2’ (610mm)<br />
10’ (3.04M)<br />
Figure 6<br />
© Travis Industries 100-01166 4040907<br />
e<br />
d