16 <strong>Stove</strong> Installation (for qualified installers only)<br />

Hearth <strong>Stove</strong> Direct<br />

Connection<br />

NOTE:<br />

Direct connections require<br />

installation of an airtight,<br />

non-combustible block-off<br />

plate or damper adapter.<br />

Interior or Exterior<br />

Masonry Chimney<br />

NOTE:<br />

This type of installation<br />

requires a UBC approved<br />

masonry connector or a<br />

factory built (U.L. Listed)<br />

wall thimble.<br />

NOTE: The entire fireplace,<br />

including chimney, must be clean<br />

and not cracked or damaged.<br />

Any damage must be repaired<br />

prior to installation of the insert.<br />

Chimney must be at least 15' tall<br />

and no greater than 33' tall.<br />

Entire fireplace, including<br />

chimney, must meet local<br />

building requirements.<br />

Combustible Mantle<br />

Floor Protection<br />

(See the section<br />

"Floor Protection<br />

Requirements" for<br />

more details)<br />

Min. 18"<br />

NOTE: The chimney must have a<br />

clay tile liner. If it does not, the<br />

installation must use a positive<br />

connection (full reline). The<br />

entire fireplace and chimney must<br />

be clean, undamaged, and meet<br />

all local building codes (UBC,<br />

etc.). Damage must be repaired<br />

prior to installation. The chimney<br />

must be 15' to 33' tall.<br />

See the section "<strong>Stove</strong><br />

Placement Requirements" for<br />

minimum clearances required.<br />

Chimney connector sections<br />

See the section<br />

"Floor Protection<br />

Requirements"<br />

<br />

<br />

Min. 18"<br />

clearance<br />

to ceiling<br />

Block-off plate or<br />

damper adapter<br />

Flue Liner<br />

Stainless steel<br />

chimney connector<br />

must Extend 1' past<br />

the block-off plate<br />

or to the flue liner<br />

Remove<br />

damper<br />

or wire it<br />

open<br />

Airtight<br />

Insulated<br />

Clean-Out<br />

See the section<br />

"<strong>Stove</strong> Placement<br />

Requirements" for<br />

minimum clearances<br />

required.<br />

Clay Liner<br />

Make sure the<br />

clean-out seals in<br />

place.<br />

Figure 16<br />

This type of<br />

installation requires<br />

a UBC approved<br />

masonry connector<br />

or a factory built<br />

(U.L. Listed) wall<br />

thimble.<br />

Figure 17<br />

© Travis Industries 93508039 4040820