Rosemount 5300 Series Superior Performance Guided Wave Radar ...
Rosemount 5300 Series Superior Performance Guided Wave Radar ...
Rosemount 5300 Series Superior Performance Guided Wave Radar ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Quick Installation Guide<br />
30<br />
IC 1 FOUNDATION fieldbus FISCO model:<br />
Ex ia IIC T4 (-50 °C < T a< +60 °C) DIP A20 T A69 °C<br />
U i = 17.5 V, I i = 380 mA, P i = 5.32 W, C i4.95 nF, L i 0.1 μH<br />
N3 Type n:<br />
HART model:<br />
Ex nL IIC T4 (-50 °C < T a < +70 °C)<br />
U i = 30 V, I i = 130 mA, P i = 1.0 W, C i7.26 nF, L i 0 μH<br />
FOUNDATION fieldbus model:<br />
Ex nL IIC T4 (-50 °C < T a < +60 °C)<br />
U i = 30 V, I i = 300 mA, P i = 1.5 W, C i4.95 nF, L i 0 μH<br />
Japanese certifications<br />
Technology Institution of Industrial Safety (TIIS) approval<br />
Special conditions for safe use (X):<br />
Refer to certificate TC20104 and TC20192.<br />
E4 1 Flameproof:<br />
4-20 mA/HART model:<br />
Transmitter: Ex d [ia] IIC T4x<br />
-20 ~ +60 °C<br />
DC 20 - 42.4 V<br />
U m = 250 V<br />
U o = 22.2 V<br />
I o = 177.5 mA<br />
P o = 0.985 W<br />
Probe: Ex Ia IIC T4X<br />
FOUNDATION fieldbus model:<br />
Transmitter: Ex d [ia] IIC T4X<br />
-20 ~ +60 °C<br />
DC 16 - 32 V<br />
U m = 250 V<br />
U o = 22.2 V<br />
I o = 177.5 mA<br />
P o = 0.985 W<br />
Probe: Ex ia IIC T4X<br />
Installation Drawing: 0<strong>5300</strong>-00548.<br />
Approval valid for HART and FOUNDATION fieldbus options.<br />
1) Ordering information code for Product Certifications, see the <strong>Rosemount</strong> <strong>5300</strong> <strong>Series</strong> Product Data Sheet<br />
(Document No. 00813-0100-4530) or the <strong>Rosemount</strong> <strong>5300</strong> <strong>Series</strong> Reference Manual<br />
(Document No. 00809-0100-4530)<br />
March 2013