➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20<br />

SENSION meters and electrodes—order information<br />

SENSION METERS ART. NO.<br />

SENSION 1 with gel-filled pH electrode 5170011<br />

Portable meter for pH, redox, temperature; inputs: 5-pin and BNC socket; batteries; gel-filled combination pH electrode with<br />

temperature sensor, 1 m cable, 1 set of SINGLET buffer solutions (pH 4.01/7.00), case<br />

SENSION 2 with gel-filled pH electrode 5172512<br />

Portable meter for pH, redox, ISE, temperature; illuminated display, autoread, data storage, GLP capability;<br />

Inputs: 5-pin and BNC socket; for operation with batteries and rechargeable batteries, with gel-filled combination pH electrode<br />

with temperature sensor, 1 m cable, 1 set of SINGLET buffer solutions (pH 4.01/7.00), batteries, case<br />

SENSION 2 with gel-filled pH electrode and docking station 5172515<br />

Description as 5172512, with docking station for mains powered operation and data documentation<br />

SENSION 5 with 4-pole conductivity measuring cell 5180010<br />

Portable meter for conductivity, TDS, salinity, temperature; illuminated display, autoread, data storage, GLP capability, inputs: 5-pin,<br />

operation with batteries and rechargeable batteries, with 4-pole graphite conductivity measuring cell, cell constant K= 0.5 cm -1 ,<br />

temperature sensor, 1 m cable, calibration solution 1,000 μS/cm, batteries, case<br />

SENSION 5 with 4-pole conductivity measuring cell and docking station 5180014<br />

Description as 5180010, with docking station for mains powered operation and data documentation<br />

SENSION 6 with oxygen electrode 5185010<br />

Portable meter for dissolved oxygen; illuminated display, autoread, data storage, GLP capability, inputs: 5-pin, operation with batteries<br />

and rechargeable batteries, with O 2 electrode, 3 m cable, 2 spare membranes, electrolyte, calibration and storage vessel, batteries, case<br />

SENSION 6 with oxygen electrode and docking station 5185014<br />

Description as 5185010, with docking station for mains powered operation and data documentation<br />

SENSION ELECTRODES AND ACCESSORIES ART. NO.<br />

Gel-filled combination pH electrode with temperature sensor, plastic stem, measuring range pH 0-14, temperature range 0-100 °C, 5193500<br />

gel electrolyte filling, 5-pin connector, 1 m cable<br />

Combination pH electrode, refillable, with temperature sensor, plastic stem, measuring range pH 0-14, temperature range 0-100 °C, 5194000<br />

refillable internal electrolyte, 5-pin connector, 1 m cable<br />

PLATINUM combination pH electrode with temperature sensor, plastic stem, measuring range pH 0-14, temperature range 0-100 °C, 5191000<br />

5-pin connector, gel dispensing function, with 2 replaceable gel-KCl cartridges, 1 m cable<br />

PLATINUM combination pH electrode with flat membrane for surfaces, with temperature sensor, plastic stem, measuring range 5191500<br />

pH 0-14, temperature range 0-80 °C, 5-pin connector, gel dispensing function, with 2 replaceable gel-KCl cartridges, 1 m cable<br />

Gel-filled redox electrode with temperature sensor, plastic stem, temperature range 0-80 °C, 5-pin connector, 1 m cable 5193900<br />

PLATINUM redox electrode with temperature sensor, plastic stem, temperature range 0-80 °C, gel dispensing function, with 5193700<br />

2 replaceable gel-KCl cartridges, 5-pin-connector, 1 m cable<br />

Gel-filled redox electrode, refillable, without temperature sensor, plastic stem, temperature range 0-80 °C, BNC connector, 1 m cable 5193200<br />

Temperature sensor, measuring range 0-80 °C, 5-pin connector 5198000<br />

Oxygen electrode, membrane-covered 2-pole Clark sensor with temperature sensor, measuring range 0-20 mg/l or 0-200%, 5197000<br />

temperature range 0-50 °C, 5-pin connector, 1 m cable<br />

Oxygen electrode, description as 5197000, with 3 m cable 5197003<br />

Oxygen electrode, description as 5197000, with 15 m cable 5197015<br />

Conductivity cell, 4-pole, graphite, cell constant K= 0.5 cm -1 , with temperature sensor, calibration solution 1,000 μS/cm, 1 m cable 5197500<br />

Conductivity cell, description as 5197500, with 3 m cable 5197503<br />

Docking station, 230 V voltage supply, for SENSION 2/5/6/156, with RS232C port for data documentation 5187502<br />

➔ Buffers for the SENSION family: see page 28<br />

➔ Other SENSION meters, electrodes and accessories on request<br />

www.greyhoundchrom.com<br />

The docking station enables the SENSION meters<br />

to be connected to the mains power supply and<br />

to transfer data to a printer and a PC<br />

25<br />

WW<br />

DW<br />

PW<br />

3