02.04.2013 Views

HACH LANGE drinking water analysis

HACH LANGE drinking water analysis

HACH LANGE drinking water analysis

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20<br />

Selection of METERLAB pH, redox and fluoride electrodes<br />

PARAMETER pH pH pH pH pH REDOX F -<br />

Applications General purpose General purpose Alkaline High KCl General purpose General purpose<br />

samples outflow gel-filled<br />

Type PHC2001 PHC2085 PHC2011 PHC2701 PHC3105 MC3051Pt ISEC301F<br />

Art. no. E16M313 E16M501 E16M317 E16M323 E16M308 E31m003 E41M017<br />

Reference system RED ROD RED ROD RED ROD RED ROD Ag/Cl Ag/Cl Ag/Cl recommended<br />

Measuring range 0-12 pH 0-12 pH 0-14 pH 0-12 pH 2-12 pH 5x10 7 –10 0 M<br />

0.01-20,000 ppm<br />

Temperature range -10 to 100 °C -10 to 100 °C 0 to 100 °C -10 to 100 °C 0 to 60 °C 0 to 80°C 0 to 50°C<br />

Min. Sample depth 18 mm 14 mm 18 mm 18 mm 18 mm<br />

Liquid junction Porous pin Porous pin Porous pin Ring-shaped Open Porous pin<br />

Special features Temperature Rugged Platinum ring sensor element Interference ions OH -<br />

➔ Buffers for the METERLAB family: see next page<br />

➔ More about METERLAB meters, electrodes and accessories on request<br />

Selection of METERLAB conductivity electrodes<br />

sensor Salt bridge solution 3 M pH range 5-7<br />

PARAMETER CONDUCTIVITY CONDUCTIVITY CONDUCTIVITY CONDUCTIVITY CONDUCTIVITY<br />

Applications General purpose General purpose Pure <strong>water</strong> Strong acids/ Low<br />

bases conductivity<br />

Type CDC566T CDC641T CDC511T CDC861T CDC267-9<br />

Art. no. E61M010 B15B001 E61M009 E16M016 E61M011<br />

Cell constant 1.0 cm -1 0.85 cm -1 1.0 cm -1 1.0 cm -1 0.1 cm -1<br />

Number of poles 4 2 4 4 2<br />

Maximum 80 °C 100 °C 80 °C 100 °C 100 °C<br />

temperature<br />

Minimum<br />

immersion depth<br />

35 mm 14 mm 3 mm 35 mm 26 mm<br />

Special features Temperature sensor Temperature sensor Temperature sensor Temperature sensor<br />

platinised platinised<br />

www.greyhoundchrom.com<br />

KCl + saturated AgCl<br />

The SAM7 sample station is a combined<br />

magnetic stirrer and electrode holder—for<br />

stable and reproducible stirring conditions<br />

27<br />

WW<br />

DW<br />

PW<br />

3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!