Turbidity measurement to ISO and EPA<br />
standards—in the laboratory and in the field<br />
Turbidity is an easily obtainable, meaningful parameter, and is firmly established in <strong>water</strong> <strong>analysis</strong>, quality<br />
assurance and process control.<br />
The 2100 series turbidimeters from <strong>HACH</strong> combine practical design with standard-compliant measurement<br />
technology. All instruments are available with the option of an infrared or a white light source in line with<br />
ISO or EPA.<br />
Precise and reliable<br />
– In detecting the slightest turbidity<br />
e.g. in <strong>drinking</strong> <strong>water</strong><br />
– In the treatment of waste<strong>water</strong> and<br />
process <strong>water</strong><br />
– In the monitoring of municipal and<br />
industrial filtration processes<br />
– In the monitoring of process <strong>water</strong><br />
streams<br />
– For quality assurance<br />
Simple calibration with<br />
STABL CAL<br />
Turbidimeters are tested and calibrated<br />
with formazin suspensions. Reliable<br />
turbidity measurement requires the<br />
preparation of a formazin standard<br />
solution, as prescribed by<br />
EN ISO 7027 for instrument calibration.<br />
With its STABL CAL range, <strong>HACH</strong> is<br />
the world’s only supplier of stabilised,<br />
directly usable, formazin primary<br />
standards in different concentrations.<br />
Comes with an <strong>analysis</strong> certificate!<br />
White light or infrared 60°<br />
www.greyhoundchrom.com<br />
The patented RATIO optical system from <strong>HACH</strong><br />
compensates for interferences with a mixture of<br />
transmitted and scattered light<br />
RATIO optical system<br />
compensates for interferences<br />
The RATIO optical system in all 2100<br />
series turbidimeters detects and compensates<br />
for interference factors such<br />
as the intrinsic colour of the sample<br />
or fluctuations in the lamp output.<br />
The measured value is determined from<br />
several signals. In practice, this means<br />
outstanding accuracy and sensitivity<br />
over the total measuring range – also<br />
at ultrahigh levels of turbidity!<br />
90°<br />
180°<br />
Four RATIO detectors<br />