Equipment for Air-Sensitive Chemistry<br />

KDS SYRINGE PUMPS<br />

Advanced microprocessor-controlled syringe pumps designed especially for low, pulse-free flow<br />

rates. Easy setup:<br />

1. Select syringe size 2. Enter volume to be<br />

dispensed<br />

Single-syringe pumps<br />

Series 100 infusion pumps. Combine precision and simplicity<br />

with ease of use and exceptional durability. The<br />

230V pumps are CE compliant. 9 x 6 x 5in. 4Flb.<br />

Features:<br />

• Holds any size syringe from 10mL to 60mL<br />

• Automatic volume control and shutoff<br />

• Last settings stored in memory<br />

• Continuous dispense volume display<br />

• Simple menu-driven setup:<br />

syringe diameter (selected from displayed table)<br />

dispense volume<br />

dispense flow rate<br />

Volts Cat. No.<br />

115 Z40,135-8<br />

230 Z40,136-6<br />

Note: For extra security when using<br />

large bore transfer needles, fasten septum<br />

to bottle or flask opening with a<br />

wrap-it tie. See the Septa Section of<br />

the <strong>Aldrich</strong> Handbook for a listing of<br />

these products.<br />

CHEM-FLEX transfer lines<br />

Especially suited for transfer of products packed in <strong>Aldrich</strong> Sure/Seal bottles.These ready-to-use<br />

transfer lines incorporate CHEM-FLEX 106 tubing which has a chemically-inert, thin-wall PTFE<br />

inner tube sheathed in clear PVC for extra strong, flexible lines that are resistant to crushing or<br />

kinking. Two 12 gauge SS needles (6 and 18in.) are connected to the CHEM-FLEX 106 tubing<br />

with nylon clamps. Liquids contact only PTFE and SS during transfers.<br />

Tubing L (in.) Cat. No.<br />

30 Z23,102-9<br />

60 Z28,175-1<br />

120 Z28,177-8<br />

3. Enter flow rate, then press<br />

start button<br />

Dual-syringe pumps<br />

Series 200 infusion pumps. All the features of Series<br />

100 pumps plus:<br />

• Holds two syringes, sizes 10mL to 140mL each<br />

• Settings can be reviewed or changed<br />

during operation<br />

• Optical encoder stall detection<br />

• Choice of unit selection<br />

• RS-232C interface for computerizing up to<br />

100 pumps<br />

• TTL interface for foot switch, timer, relay<br />

control; outputs for run indicator, valve control<br />

• 11 x 9 x 5Fin. 9lb.<br />

Volts Cat. No.<br />

115 Z40,137-4<br />

230 Z40,138-2