Proven operational safety<br />
and long life through type<br />
and suitability tests!<br />
0.15<br />
11.4 Tests and qualifications<br />
11.4.1 Raw material and material reception<br />
All materials used undergo receiving control<br />
by the quality management department. The<br />
materials used are qualified, corresponding<br />
to requirements by material tests according<br />
to ASME and DIN EN 10204.<br />
11.4.2 Monitoring of manufacture<br />
Manufacture is monitored via accompanying<br />
quality control according to the QM manual.<br />
In particular, for nuclear applications the<br />
quality-assuring requirements according to<br />
ASME III NF and KTA are fulfilled.<br />
11.4.3 Final inspection<br />
Before shipment, constant and spring hangers<br />
as well as shock absorbers undergo a function<br />
test on test benches by quality management<br />
personnel. The tests are carried out<br />
using computer-assisted equipment. The<br />
values measured can be recorded by means<br />
of a diagram. In addition, for constant and<br />
spring hangers the digital values can be<br />
printed out over the whole travel range.<br />
The specific test benches employed undergo<br />
regular inspections by an independent supervisory<br />
body.<br />
11.4.4 Documentation on shipment<br />
If so ordered, the materials used are documented<br />
by certification from material tests according<br />
to ASME and DIN EN 10204. In addition,<br />
the results of the function tests can be<br />
confirmed by issuing an acceptance test<br />
certificate, also from a supervisory body if<br />
desired.<br />
Stress reports according to particular specifications<br />
and quality-assuring documents can<br />
be agreed between customer, manufacturer<br />
and supervisory body.<br />
11.5 Suitability test according to KTA 3205.3<br />
and type test according to VGB R 510 L<br />
For the use of series-made standard supports<br />
in conventional power plants, a type test by a<br />
supervisory body (according to § 14 of the<br />
appliance safety law GSG) is foreseen in the<br />
VGB code R 510 L.<br />
For use in nuclear installations a corresponding<br />
suitability test, according to directive 35<br />
of the TÜV’s nuclear technology supervisory<br />
body at the Vd TÜV, is prescribed by nuclear<br />
code KTA 3205.3.<br />
The test program prescribed comprises in<br />
essence the following components:<br />
➜ inspection of the quality management<br />
program<br />
➜ inspection of material used<br />
➜ inspection of the design documentation<br />
➜ inspection of design report summaries<br />
➜ experimental function tests<br />
➜ experimental overload tests<br />
➜ experimental testing of continuous<br />
load capacity<br />
For the broad range of <strong>LISEGA</strong> products, type<br />
and suitability tests have been conducted<br />
by the German TÜV and VGB and the corresponding<br />
permits granted. Qualifications can<br />
be supplied on request