ECL Comfort 110 Application 116 Constant temperature control of ...

ECL Comfort 110 Application 116 Constant temperature control of ...

ECL Comfort 110 Application 116 Constant temperature control of ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

How to navigate?<br />

What do the symbols mean?<br />

<br />

<br />

<br />

Adjust <strong>temperature</strong>s and values.<br />

Switch between menu lines.<br />

Select / return.<br />

2 sec.<br />

Return to daily user menu.<br />

The desired flow <strong>temperature</strong> is influenced by for example return <strong>temperature</strong>.<br />

The actuator closes the <strong>control</strong> valve.<br />

The actuator opens the <strong>control</strong> valve.<br />

The actuator does not activate the valve.<br />

The pump is ON.<br />

The pump is OFF.<br />

The <strong>control</strong>ler is in setback mode.<br />

The <strong>control</strong>ler is in pre-setback mode (the symbol is blinking).<br />

The <strong>control</strong>ler is in comfort mode.<br />

The <strong>control</strong>ler is in pre-comfort mode (the symbol is blinking).<br />

Safety Note<br />

To avoid injury <strong>of</strong> persons and damages to the device, it is absolutely necessary to read and<br />

observe these instructions carefully. The warning sign is used to emphasize special conditions<br />

that should be taken into consideration.<br />

This symbol indicates that this particular piece <strong>of</strong> information should be read with<br />

special attention.<br />

VI.KT.F1.02 © Danfoss 05/2007 DH-SMT/DK<br />

Table <strong>of</strong> Contents<br />

Line Page<br />

Introduction .................................................................................................. 6<br />

Settings overview 7<br />

Daily use ........................................................................................................ 8<br />

Temperatures 8<br />

Select <strong>control</strong> mode 9<br />

Set your personal schedule 9<br />

Maintenance ............................................................................................... 11<br />

Date - time 1000 11<br />

Flow temp. (flow <strong>temperature</strong> <strong>control</strong>) 2000 11<br />

Temp. min. (flow temp. limit, min.) 2177 11<br />

Temp. max. (flow temp. limit, max.) 2178 11<br />

Return T limit (return temp. limitation) 4000 12<br />

Limit (return temp. limitation) 4030 12<br />

Gain - max. (return temp. limitation - max. influence) 4035 13<br />

Gain - min. (return temp. limitation - min. influence) 4036 14<br />

Intgr. time (time constant for return temp. limitation) 4037 14<br />

Control param. (<strong>control</strong> parameters) 6000 15<br />

Auto tuning 6173 15<br />

Motor prot. (motor protection) 6174 16<br />

Xp (proportional band) 6184 16<br />

Tn (integration time constant) 6185 16<br />

M1 run (running time <strong>of</strong> the motorized <strong>control</strong> valve) 6186 16<br />

Nz (neutral zone) 6187 17<br />

<strong>Application</strong> 7000 18<br />

P1 exercise (pump exercise) 7022 18<br />

M1 exercise (valve exercise) 7023 18<br />

P1 frost T (frost protection) 7077 18<br />

P1 heat T (heat demand) 7078 18<br />

Standby T (standby <strong>temperature</strong>) 7093 19<br />

Ext. (external override) 7141 19<br />

Min. on time (min. activation time gear motor) 7189 19<br />

Daylight (daylight saving time changeover) 7198 20<br />

<strong>ECL</strong> address (master / slave address) 7199 20<br />

Type 7600 21<br />

Service 8000 22<br />

Code no. 8300 22<br />

Ver. (version no.) 8301 22<br />

Backlight (display brightness) 8310 22<br />

Contrast (display contrast) 8311 22<br />

Language 8315 23<br />

MOD address (MODBUS address) 8320 23<br />

DH-SMT/DK VI.KT.F1.02 © Danfoss 05/2007