3. CONDITION <strong>OF</strong> STEEL <strong>GIRDERS</strong> <strong>OF</strong> BR.NO. 73 &75 (OLD)<br />

3.1 The bridge <strong>No</strong>. 73 & 75 ( abandoned ) are located on Vasai Creek<br />

between Bhainder and Naigaon stations of CCG – VR suburban<br />

section. The old is located on the west most side of the existing bridge.<br />

There are 69 x 2 = 138 nos. of 18.3 m span girders on bridge <strong>No</strong>. 73 and<br />

25 x 2 = 50 nos. of 18.3 m span girders in bridge <strong>No</strong>. 75. Thus, there are<br />

188 nos. girders of 18.3 m effective span. There 8 nos. of 6.1 m span<br />

girder in bridge <strong>No</strong>. 73 & 75 which can not be reused since these have<br />

already completed their fatigue life.<br />

3.2 The details of girders are as follows:<br />

a) Effective Span - 18.3 m<br />

b) Overall length - 18.95 m<br />

c) Height at end - 1.87 m<br />

d) Height at center - 1.91 m<br />

e) Flange width - 430 mm<br />

f) C/C of girder leaves - 1.88 m<br />

g) Loading Standard - BG standard of 1916<br />

h) Drawing <strong>No</strong>. - CEN/57728/11-D<br />

i) Manufactured by - M/s P& W Maglellan Ltd., BB & CI. Co. -<br />

1923, Clutha Works Glasgow.<br />

3.3 The girders of the bridge were inspected visually by Dy. CE (Br.) BL and<br />

the following points were brought out:<br />

The girders in the bridge can be classified into two broad categories<br />

based on visual inspections:<br />

a) Type I : The type I girders are having:<br />

i) Corrosion in top flange plates upto 7 mm at sleeper seat locations i.e.<br />

at every 65 cms spacing.<br />

ii) 80 % gussets are having corrosion by minimum 4 mm, out of total 8<br />

mm thickness. Many gussets are perforated.<br />

iii) 30-35 % rivets have lost more than 50 % head due to corrosion in top<br />

flange.<br />

iv) Bracings are generally in satisfactory condition, except the end cross<br />

frame top lateral angles, which are corroded and reduced in thickness.<br />

v) There is slight corrosion in the bottom angle of main girder and the<br />

same is generally OK.<br />

vi) There is corrosion of upto 1 mm at the junction of the web plate with<br />

bottom main angle.<br />

24