David Coulsey<br />

Kiewit Louisiana Co.<br />

<str<strong>on</strong>g>Replacing</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> <str<strong>on</strong>g>Stay</str<strong>on</strong>g> <str<strong>on</strong>g>Cables</str<strong>on</strong>g> <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g><br />

<strong>Hale</strong> <strong>Boggs</strong> <strong>Memorial</strong> <strong>Bridge</strong><br />

(I (I‐310‐Lu<strong>li</strong>ng) L <strong>li</strong> )<br />

1


Lu<strong>li</strong>ng u g<strong>Bridge</strong> dge Project– oject By y <str<strong>on</strong>g>the</str<strong>on</strong>g> t eNumbers u be s<br />

Original C<strong>on</strong>structi<strong>on</strong> Completi<strong>on</strong> …. 1983<br />

Vehicles Vhil Crossing C i Per P Day D ….. 45,000<br />

Span Length…… 2,225 ft<br />

Pyl<strong>on</strong> Height Height……. 400 ft<br />

Number of <str<strong>on</strong>g>Stay</str<strong>on</strong>g> <str<strong>on</strong>g>Cables</str<strong>on</strong>g> to Replace…….. 72 ea<br />

3


Lu<strong>li</strong>ng u g<strong>Bridge</strong> dge Project oject ‐ Why y We’re e eHere ee<br />

Corrosi<strong>on</strong> of<br />

Existing <str<strong>on</strong>g>Cables</str<strong>on</strong>g><br />

All C<str<strong>on</strong>g>Cables</str<strong>on</strong>g> bl h have<br />

Damage<br />

39 of 72 rated<br />

Critical<br />

4


Existing Cable <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s<br />

Parallel wire system<br />

Presc<strong>on</strong> anchorage<br />

111‐307 ¼” dia. 270ksi bare wire<br />

Individually “butt<strong>on</strong>‐headed”<br />

Grout filled stay pipe<br />

5


Deck Anchorage<br />

6


New Cable <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s<br />

VSL SSI2000 Parallel Strand System<br />

Multiple corrosi<strong>on</strong> barriers<br />

- Individually greased and shea<str<strong>on</strong>g>the</str<strong>on</strong>g>d 0.62” strand<br />

- HDPE <str<strong>on</strong>g>Stay</str<strong>on</strong>g> pipe<br />

Stringent testing requirements<br />

Strand by strand replaceabi<strong>li</strong>ty<br />

7


Cable Operati<strong>on</strong>s Sequence<br />

Install Temporary <str<strong>on</strong>g>Stay</str<strong>on</strong>g> <str<strong>on</strong>g>Cables</str<strong>on</strong>g><br />

Lift‐Off, De‐Stress, & Remove Existing <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s<br />

Modify Existing Structure @ Anchor Locati<strong>on</strong>s<br />

Install New Cable <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s<br />

De‐Stress, Jump, & Re‐Install Temporary <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s<br />

11


1 & 6 400 11,132 132<br />

1 & 5 280 1,025<br />

2 & 5 260 862<br />

3 & 4 260 610<br />

12


De‐Stress & Lower Existing g <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s y<br />

Existing stay cables de‐stressed in a pair<br />

KLC required to find <str<strong>on</strong>g>the</str<strong>on</strong>g> force in <str<strong>on</strong>g>the</str<strong>on</strong>g> existing stay cables<br />

Four phases to <str<strong>on</strong>g>the</str<strong>on</strong>g> De‐Stress & Lower Operati<strong>on</strong>:<br />

1. Lift Off & De‐Stress <str<strong>on</strong>g>Stay</str<strong>on</strong>g><br />

2. Lower <str<strong>on</strong>g>Stay</str<strong>on</strong>g> from <str<strong>on</strong>g>the</str<strong>on</strong>g> Pyl<strong>on</strong><br />

33. Cut <str<strong>on</strong>g>Stay</str<strong>on</strong>g> Cable<br />

4. Load Cable for Scrap<br />

Backspan<br />

Mainspan<br />

16


Composite Photo of Deck Level Anchor with De-<br />

Tensi<strong>on</strong>ing Adapter Socket Installed<br />

17


Install New <str<strong>on</strong>g>Stay</str<strong>on</strong>g>s y<br />

Install New <str<strong>on</strong>g>Stay</str<strong>on</strong>g> Anchorages/Comp<strong>on</strong>ents<br />

Weld HDPE <str<strong>on</strong>g>Stay</str<strong>on</strong>g> Pipe<br />

Hoist Pipe<br />

Install & Stress Strand<br />

Install Dampers and close up<br />

20


New e <str<strong>on</strong>g>Stay</str<strong>on</strong>g> Comp<strong>on</strong>ents Co po e ts – Deck ec Level ee<br />

Anchor Chair Exit Pipe<br />

& Anchor<br />

21


New e <str<strong>on</strong>g>Stay</str<strong>on</strong>g> Comp<strong>on</strong>ents– Co po e ts Pyl<strong>on</strong> yo Level ee<br />

23


Installed Pyl<strong>on</strong> Anchor<br />

24


New <str<strong>on</strong>g>Stay</str<strong>on</strong>g> y Comp<strong>on</strong>ents p – HDPE Pipe p Weld<br />

Fuse/Weld pipes toge<str<strong>on</strong>g>the</str<strong>on</strong>g>r with Butt Fusi<strong>on</strong> Hydro‐<br />

Electric Machine<br />

25


New <str<strong>on</strong>g>Stay</str<strong>on</strong>g>‐ Pipe Hoist<br />

27