<strong>Paisley</strong> <strong>Gilmour</strong> <strong>Street</strong> <strong>Railway</strong> <strong>Station</strong> <strong>Canopy</strong> <strong>Renewal</strong><br />

5. Details of proposal design and materials.<br />

5.1. Glazing.<br />

The roof glazing system consists of 6.4mm laminated planar glass supported<br />

and restrained by PL6 glazing bars and supported by steel purlins which span<br />

between new steel pitched roof beams.<br />

5.2. Foundations and substructure.<br />

It is anticipated that existing column foundations which are supported on fill<br />

between the retaining walls of the original station will require strengthening.<br />

The form of strengthening is envisaged to be enlargement of the existing pad<br />

foundations using dowels and reinforced concrete to reduce bearing<br />

pressures on the substructures.<br />

5.3. Superstructure.<br />

The existing lattice girders will be strengthened using the following<br />

techniques:<br />

Additional flange plates will be bolted to the soffit of the main lattice girders<br />

in order to enhance the bending capacity of the girders.<br />

The main lattice girder web members will be strengthened by the addition<br />

of angles or channels to the end members in order to carry the shear<br />

forces from the end of the beam down to the supports.<br />

The main strengthening works involve the addition of a rolled steel beam<br />

section above the main lattice girders in order to significantly increase the<br />

section depth. The beam will be bolted at approximately 150mm centres to<br />

the top flange of the girder in order to provide a longitudinal shear<br />

connection. The soffit of the proposed rolled steel section will be notched<br />

over the locations where the OHLE supports are positioned above the top<br />

flange of the lattice girders.<br />

The rolled steel beams will act as valley girders and will accept the main<br />

pitched roof beam sections. The roof beams will be tied in order to limit<br />

lateral loading effects on the existing lattices during construction.<br />

The existing columns have been found to be inadequate to resist wind<br />

loading effects and therefore horizontal plan bracing will be introduced in<br />

the end bays in order to carry the loads back to the main masonry<br />

supporting walls. These loads will be distributed along the length of the<br />

wall by longitudinal beams positioned just in front of the masonry walls.<br />

Additional longitudinal beams will be included along platform 2/3 above the<br />

existing bow tie members in order the distribute loads down the length of<br />

the station.<br />

The roof is joined to the wall of the building with lead capping to the<br />

cornice and blocking course to parapet. This is detailed in drawing<br />

A057311-31-A-301.<br />

Laura Mitchell for NETWORK RAIL Page 4 of 6