Mai 2009 – Pages 01-44 - Farnell
Mai 2009 – Pages 01-44 - Farnell
Mai 2009 – Pages 01-44 - Farnell
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Digital Oscilloscope Oscilloscope<br />
LeCroy WaveAce<br />
Long Memory<br />
WaveSurfer Oscilloscope<br />
Xs-A and MXs-A<br />
Mask Test<br />
Key Features:<br />
• Simple to use with auto set-up<br />
• Easyscope remote control software<br />
included<br />
• Unique waveform sequence recorder<br />
• Pass/Fail testing<br />
• 5.7" colour display with zoom on all<br />
models<br />
• 60 MHz, 100 MHz, 200 MHz and 300<br />
MHz B/W<br />
• Sample rates up to 2 GS/s<br />
Introducing the LeCroy<br />
WaveSurfer Xs-A - the very<br />
latest version of the<br />
highly popular oscillo-<br />
scope. The new WaveSurfer now featurers:<br />
• New PC system with faster processor, more<br />
RAM and faster hard drive resulting in some<br />
process being up to 2 times faster<br />
• 5 Mpts/ch memory as standard<br />
• New operating system<br />
• LXi support (class C)<br />
• Standard HDTV Trigger<br />
• M-Types also offer:<br />
10 Mpts/ch memory<br />
5 GS/s per channel on 1 GHz model, interleaved on 600 MHz<br />
Advanced trigger & MathSurf included as standard<br />
LabNotebook<br />
Math<br />
Parameter<br />
• Long Waveform Memory - 4 kpts/Ch and 8<br />
kpts/Ch configurations<br />
• Advanced Triggering - Edge, Width, Video,<br />
Rise Time<br />
• 32 automatic measurements<br />
• Multi-language User Interface and Context<br />
Sensitive Help<br />
• Large internal waveform and setup storage<br />
• 4 math functions plus FFT<br />
• USB host and device connections for printers,<br />
memory sticks and PC remote control<br />
Model No. 102 112 202 212 222 232<br />
Order Code 163-3307 163-3308 163-3309 163-3310 163-3311 163-3312<br />
Input Channels 2<br />
Bandwidth 60 MHz 100 MHz 60 MHz 100 MHz 200 MHz 300 MHz<br />
Rise Time 5.8 ns 3.5 ns 5.8 ns 3.5 ns 1.75 ns 1.2 ns<br />
Input Coupling 1 MΩ ‘‘ 13 pF 1 MΩ ‘‘ 13 pF, 50 Ω<br />
Display 5.7" Color, 320 x 240 resolution<br />
Sample rate (Equivalent Time) 50 GS/s<br />
Peak Detect Period 10 ns<br />
Memory Length 4 kpts/Ch 9 kpts/Ch<br />
Vertical Resolution 8 bits<br />
Vertical Sensitivity 2 mV/div-5 V/div Bandwidth Limiting<br />
Bandwidth Limiting Filter 20 MHz<br />
Maximum Input Voltage 400 V CAT II<br />
Probes 10:1, 1:1 Switchable Passive Probe (one per channel)<br />
Timebase Range 5 ns/div-50 s/div 2.5 ns/div-50 s/div<br />
Mftrs. Price Each<br />
List No. Order Code 1+<br />
WAVEACE 102 163-3307 8.170,00<br />
WAVEACE 112 163-3308 9.850,00<br />
WAVEACE 202 163-3309 9.850,00<br />
WAVEACE 212 163-3310 12.425,00<br />
WAVEACE 222 163-3311 15.050,00<br />
WAVEACE 232 163-3312 20.500,00<br />
Mftrs. Price Each<br />
List No. Order Code 1+ 5+<br />
WAVESURFER 104MXS-A 169-8117 104.510,00 103.464,90<br />
WAVESURFER 64MXS-A 169-8118 93.930,00 92.990,70<br />
WAVESURFER <strong>44</strong>MXS-A 169-8119 78.530,00 77.7<strong>44</strong>,70<br />
WAVESURFER 24MXS-A 169-8120 68.730,00 68.042,70<br />
WAVESURFER 104XS-A 169-8121 95.375,00 94.421,25<br />
WAVESURFER 64XS-A 169-8122 85.<strong>44</strong>5,00 84.590,55<br />
WAVESURFER <strong>44</strong>XS-A 169-8123 68.730,00 68.042,70<br />
WAVESURFER 24XS-A 169-8124 58.890,00 58.3<strong>01</strong>,10<br />
WAVESURFER 62XS-A 169-8125 71.270,00 70.557,30<br />
WAVESURFER 42XS-A 169-8127 56.525,00 55.959,75<br />
Find the latest products online at www.farnell.com<br />
DPO / MSO<br />
DPO2<strong>01</strong>2 DPO2024<br />
MSO2<strong>01</strong>2<br />
The MSO2000 and DPO2000 Series<br />
digital phosphor oscilloscopes<br />
(DPOs) deliver the performance and<br />
tools you need to visualize your sig-<br />
nals and find answers quickly. The DPO2000 Series are<br />
the first oscilloscopes to provide 1 M points of usable<br />
record length on all channels, serial trigger and decode<br />
MSO2024<br />
analysis options, a variable low-pass filter that also<br />
allows you to see signal details to the oscilloscope’s full bandwidth and all in a compact form<br />
factor. The MSO2000 Series adds 16 integrated digital channels, enabling you to visualize and<br />
time correlate analog and digital signals on a single instrument. This integration extends<br />
triggering functionality across all 20 channels - which is ideal for debugging mixed analog and<br />
digital designs.<br />
Features & Benefits<br />
• Key Performance Specifications<br />
• 100 MHz and 200 MHz bandwidth models<br />
• 2 or 4 analog channels<br />
• 16 digital channels (MSO2000 Series)<br />
• Sample rates up to 1 GS/s on all channels<br />
MSO2<strong>01</strong>2 MSO2<strong>01</strong>4 MSO2<strong>01</strong>4<br />
Vertical System Analog Channels DPO2<strong>01</strong>2 DPO2<strong>01</strong>4 DPO2024<br />
Input Channels 2 4 4<br />
Analog Bandwidth*1 (-3 dB) 100 MHz 100 MHz 200 MHz<br />
Calculated Rise Time 3.5 ns 3.5 ns 2.1 ns<br />
Hardware Bandwidth Limits 20 MHz<br />
Input Coupling AC, DC, GND<br />
Input Impedance 1 MΩ ±2%, 11.5 pF ±2 pF<br />
Input Sensitivity Range 2 mV/div to 5 V/div<br />
Vertical Resolution 8 bits<br />
Horizontal System - Analog Channels<br />
Maximum Sample Rate (all channels) 1 GS/s<br />
Minimum Peak Detect Pulse Width 7.0 ns 3.5 ns<br />
Maximum Record Length (all channels) 1 M points<br />
Timebase Range 4 ns to 100 s 2 ns to 100 s<br />
Timebase Delay Time Range -10 div to 5000 s<br />
Channel-to-Channel Deskew Range ±100 ns<br />
Timebase Accuracy ±25 ppm<br />
Agilent U14<strong>01</strong>A Handheld<br />
Multi-function Calibrator/Meter<br />
(HxWxD) 192 x 90 x 54mm<br />
Key Features:<br />
Simultaneous source and measure<br />
• 1 Mega sample record length on all channels<br />
• 5,000 wfm/s maximum waveform capture<br />
rate<br />
• Suite of advanced triggers<br />
Mftrs. Price Each<br />
List No. Description Order Code 1+<br />
DPO2<strong>01</strong>2 Oscilloscope, DPO 2CH 100MHz 165-0367 21.280,00<br />
DPO2<strong>01</strong>4 Oscilloscope, DPO 4CH 100MHz 165-0368 25.650,00<br />
DPO2024 Oscilloscope, DPO 4CH 200MHz 165-0369 30.875,00<br />
MSO2<strong>01</strong>2 Oscilloscope, MSO 2CH 100MHz 165-0370 29.545,00<br />
MSO2<strong>01</strong>4 Oscilloscope, MSO 4CH 100MHz 165-0371 35.530,00<br />
MSO2024 Oscilloscope, MSO 4CH 200MHz 165-0372 42.560,00<br />
Accessories 1+<br />
DPO2AUTO Module, Automotive Serial Trigger 166-5104 5.748,00<br />
DPO2COMP Module, Computer Serial Trigger 166-5105 5.748,00<br />
DPO2CONN Module, Ethernet & External Monitor 166-5106 3.268,00<br />
DPO2EMBD Module, Embedded Serial Trigger 166-5107 5.748,00<br />
P2221 Passive Probe, 1X/10X 200MHz 166-5109 962,00<br />
RMD2000 Rackmount Kit 166-5111 3.835,00<br />
ACD2000 Sort Large Case 166-5112 1.755,00<br />
The U14<strong>01</strong>A Handheld Multi-function Calibrator/Meter<br />
from Agilent Technologies<br />
sets new levels of versatility and conve-<br />
nience in process control calibration with<br />
its ability to simultaneously source and measure. Such versatility,<br />
complete with high performance DMM capability, in an<br />
attractive price-value point, sets the U14<strong>01</strong>A strides ahead of<br />
other instruments in its class.<br />
Agilent’s U14<strong>01</strong>A Handheld Multi-function Calibrator/Meter incorporates<br />
complete DMM performance into a process calibration<br />
tool, with the unique ability to both source and measure<br />
simultaneously. Capable of generating constant voltage and<br />
current, it also functions as a pulse signal generator, well-suited<br />
for calibration of process control devices such as flow meters.<br />
Simultaneously, the U14<strong>01</strong>A allows users to conveniently utilise<br />
its DMM functions as well, such as to measure output mA<br />
readings from devices such as transmitters and isolators. As<br />
such, calibration needs that require both sourcing and mea-<br />
suring at the same time are conveniently met - all at an attractive<br />
price point. Its standalone DMM features are just as versatile to be used on the electronics<br />
bench. Capable of measuring both AC and DC signals, it readily tackles everyday DMM tasks<br />
such as measuring resistance, frequency, temperature and diode checking.<br />
Telefaks 800 146 76 800 146 70 www.farnell.no<br />
41<br />
Test Equipment<br />
Prices in NOK excluding moms<br />
41