Digital Oscilloscope Oscilloscope<br />

LeCroy WaveAce<br />

Long Memory<br />

WaveSurfer Oscilloscope<br />

Xs-A and MXs-A<br />

Mask Test<br />

Key Features:<br />

• Simple to use with auto set-up<br />

• Easyscope remote control software<br />

included<br />

• Unique waveform sequence recorder<br />

• Pass/Fail testing<br />

• 5.7" colour display with zoom on all<br />

models<br />

• 60 MHz, 100 MHz, 200 MHz and 300<br />

MHz B/W<br />

• Sample rates up to 2 GS/s<br />

Introducing the LeCroy<br />

WaveSurfer Xs-A - the very<br />

latest version of the<br />

highly popular oscillo-<br />

scope. The new WaveSurfer now featurers:<br />

• New PC system with faster processor, more<br />

RAM and faster hard drive resulting in some<br />

process being up to 2 times faster<br />

• 5 Mpts/ch memory as standard<br />

• New operating system<br />

• LXi support (class C)<br />

• Standard HDTV Trigger<br />

• M-Types also offer:<br />

10 Mpts/ch memory<br />

5 GS/s per channel on 1 GHz model, interleaved on 600 MHz<br />

Advanced trigger & MathSurf included as standard<br />

LabNotebook<br />

Math<br />

Parameter<br />

• Long Waveform Memory - 4 kpts/Ch and 8<br />

kpts/Ch configurations<br />

• Advanced Triggering - Edge, Width, Video,<br />

Rise Time<br />

• 32 automatic measurements<br />

• Multi-language User Interface and Context<br />

Sensitive Help<br />

• Large internal waveform and setup storage<br />

• 4 math functions plus FFT<br />

• USB host and device connections for printers,<br />

memory sticks and PC remote control<br />

Model No. 102 112 202 212 222 232<br />

Order Code 163-3307 163-3308 163-3309 163-3310 163-3311 163-3312<br />

Input Channels 2<br />

Bandwidth 60 MHz 100 MHz 60 MHz 100 MHz 200 MHz 300 MHz<br />

Rise Time 5.8 ns 3.5 ns 5.8 ns 3.5 ns 1.75 ns 1.2 ns<br />

Input Coupling 1 MΩ ‘‘ 13 pF 1 MΩ ‘‘ 13 pF, 50 Ω<br />

Display 5.7" Color, 320 x 240 resolution<br />

Sample rate (Equivalent Time) 50 GS/s<br />

Peak Detect Period 10 ns<br />

Memory Length 4 kpts/Ch 9 kpts/Ch<br />

Vertical Resolution 8 bits<br />

Vertical Sensitivity 2 mV/div-5 V/div Bandwidth Limiting<br />

Bandwidth Limiting Filter 20 MHz<br />

Maximum Input Voltage 400 V CAT II<br />

Probes 10:1, 1:1 Switchable Passive Probe (one per channel)<br />

Timebase Range 5 ns/div-50 s/div 2.5 ns/div-50 s/div<br />

Mftrs. Price Each<br />

List No. Order Code 1+<br />

WAVEACE 102 163-3307 8.170,00<br />

WAVEACE 112 163-3308 9.850,00<br />

WAVEACE 202 163-3309 9.850,00<br />

WAVEACE 212 163-3310 12.425,00<br />

WAVEACE 222 163-3311 15.050,00<br />

WAVEACE 232 163-3312 20.500,00<br />

Mftrs. Price Each<br />

List No. Order Code 1+ 5+<br />

WAVESURFER 104MXS-A 169-8117 104.510,00 103.464,90<br />

WAVESURFER 64MXS-A 169-8118 93.930,00 92.990,70<br />

WAVESURFER <strong>44</strong>MXS-A 169-8119 78.530,00 77.7<strong>44</strong>,70<br />

WAVESURFER 24MXS-A 169-8120 68.730,00 68.042,70<br />

WAVESURFER 104XS-A 169-8121 95.375,00 94.421,25<br />

WAVESURFER 64XS-A 169-8122 85.<strong>44</strong>5,00 84.590,55<br />

WAVESURFER <strong>44</strong>XS-A 169-8123 68.730,00 68.042,70<br />

WAVESURFER 24XS-A 169-8124 58.890,00 58.3<strong>01</strong>,10<br />

WAVESURFER 62XS-A 169-8125 71.270,00 70.557,30<br />

WAVESURFER 42XS-A 169-8127 56.525,00 55.959,75<br />

Find the latest products online at www.farnell.com<br />

DPO / MSO<br />

DPO2<strong>01</strong>2 DPO2024<br />

MSO2<strong>01</strong>2<br />

The MSO2000 and DPO2000 Series<br />

digital phosphor oscilloscopes<br />

(DPOs) deliver the performance and<br />

tools you need to visualize your sig-<br />

nals and find answers quickly. The DPO2000 Series are<br />

the first oscilloscopes to provide 1 M points of usable<br />

record length on all channels, serial trigger and decode<br />

MSO2024<br />

analysis options, a variable low-pass filter that also<br />

allows you to see signal details to the oscilloscope’s full bandwidth and all in a compact form<br />

factor. The MSO2000 Series adds 16 integrated digital channels, enabling you to visualize and<br />

time correlate analog and digital signals on a single instrument. This integration extends<br />

triggering functionality across all 20 channels - which is ideal for debugging mixed analog and<br />

digital designs.<br />

Features & Benefits<br />

• Key Performance Specifications<br />

• 100 MHz and 200 MHz bandwidth models<br />

• 2 or 4 analog channels<br />

• 16 digital channels (MSO2000 Series)<br />

• Sample rates up to 1 GS/s on all channels<br />

MSO2<strong>01</strong>2 MSO2<strong>01</strong>4 MSO2<strong>01</strong>4<br />

Vertical System Analog Channels DPO2<strong>01</strong>2 DPO2<strong>01</strong>4 DPO2024<br />

Input Channels 2 4 4<br />

Analog Bandwidth*1 (-3 dB) 100 MHz 100 MHz 200 MHz<br />

Calculated Rise Time 3.5 ns 3.5 ns 2.1 ns<br />

Hardware Bandwidth Limits 20 MHz<br />

Input Coupling AC, DC, GND<br />

Input Impedance 1 MΩ ±2%, 11.5 pF ±2 pF<br />

Input Sensitivity Range 2 mV/div to 5 V/div<br />

Vertical Resolution 8 bits<br />

Horizontal System - Analog Channels<br />

Maximum Sample Rate (all channels) 1 GS/s<br />

Minimum Peak Detect Pulse Width 7.0 ns 3.5 ns<br />

Maximum Record Length (all channels) 1 M points<br />

Timebase Range 4 ns to 100 s 2 ns to 100 s<br />

Timebase Delay Time Range -10 div to 5000 s<br />

Channel-to-Channel Deskew Range ±100 ns<br />

Timebase Accuracy ±25 ppm<br />

Agilent U14<strong>01</strong>A Handheld<br />

Multi-function Calibrator/Meter<br />

(HxWxD) 192 x 90 x 54mm<br />

Key Features:<br />

Simultaneous source and measure<br />

• 1 Mega sample record length on all channels<br />

• 5,000 wfm/s maximum waveform capture<br />

rate<br />

• Suite of advanced triggers<br />

Mftrs. Price Each<br />

List No. Description Order Code 1+<br />

DPO2<strong>01</strong>2 Oscilloscope, DPO 2CH 100MHz 165-0367 21.280,00<br />

DPO2<strong>01</strong>4 Oscilloscope, DPO 4CH 100MHz 165-0368 25.650,00<br />

DPO2024 Oscilloscope, DPO 4CH 200MHz 165-0369 30.875,00<br />

MSO2<strong>01</strong>2 Oscilloscope, MSO 2CH 100MHz 165-0370 29.545,00<br />

MSO2<strong>01</strong>4 Oscilloscope, MSO 4CH 100MHz 165-0371 35.530,00<br />

MSO2024 Oscilloscope, MSO 4CH 200MHz 165-0372 42.560,00<br />

Accessories 1+<br />

DPO2AUTO Module, Automotive Serial Trigger 166-5104 5.748,00<br />

DPO2COMP Module, Computer Serial Trigger 166-5105 5.748,00<br />

DPO2CONN Module, Ethernet & External Monitor 166-5106 3.268,00<br />

DPO2EMBD Module, Embedded Serial Trigger 166-5107 5.748,00<br />

P2221 Passive Probe, 1X/10X 200MHz 166-5109 962,00<br />

RMD2000 Rackmount Kit 166-5111 3.835,00<br />

ACD2000 Sort Large Case 166-5112 1.755,00<br />

The U14<strong>01</strong>A Handheld Multi-function Calibrator/Meter<br />

from Agilent Technologies<br />

sets new levels of versatility and conve-<br />

nience in process control calibration with<br />

its ability to simultaneously source and measure. Such versatility,<br />

complete with high performance DMM capability, in an<br />

attractive price-value point, sets the U14<strong>01</strong>A strides ahead of<br />

other instruments in its class.<br />

Agilent’s U14<strong>01</strong>A Handheld Multi-function Calibrator/Meter incorporates<br />

complete DMM performance into a process calibration<br />

tool, with the unique ability to both source and measure<br />

simultaneously. Capable of generating constant voltage and<br />

current, it also functions as a pulse signal generator, well-suited<br />

for calibration of process control devices such as flow meters.<br />

Simultaneously, the U14<strong>01</strong>A allows users to conveniently utilise<br />

its DMM functions as well, such as to measure output mA<br />

readings from devices such as transmitters and isolators. As<br />

such, calibration needs that require both sourcing and mea-<br />

suring at the same time are conveniently met - all at an attractive<br />

price point. Its standalone DMM features are just as versatile to be used on the electronics<br />

bench. Capable of measuring both AC and DC signals, it readily tackles everyday DMM tasks<br />

such as measuring resistance, frequency, temperature and diode checking.<br />

Telefaks 800 146 76 800 146 70 www.farnell.no<br />

41<br />

Test Equipment<br />

Prices in NOK excluding moms<br />

41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!