ClearPath Plus Server<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />

I/O <strong>Reference</strong><br />

January 2007


ClearPath Plus Server<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />

I/O <strong>Reference</strong><br />

January 2007 6871 6364–003<br />

unisys<br />

imagine it. done.


NO WARRANTIES OF ANY NATURE ARE EXTENDED BY THIS DOCUMENT. Any product or related information<br />

described herein is only furnished pursuant <strong>and</strong> subject to the terms <strong>and</strong> conditions of a duly executed agreement to<br />

purchase or lease equipment or to license software. The only warranties made by Unisys, if any, with respect to the<br />

products described in this document are set forth in such agreement. Unisys cannot accept any financial or other<br />

responsibility that may be the result of your use of the information in this document or software material, including<br />

direct, special, or consequential damages.<br />

You should be very careful to ensure that the use of this information <strong>and</strong>/or software material complies with the laws,<br />

rules, <strong>and</strong> regulations of the jurisdictions with respect to which it is used.<br />

The information contained herein is subject to change without notice. Revisions may be issued to advise of such<br />

changes <strong>and</strong>/or additions.<br />

Notice to U.S. Government End Users: This is commercial computer software or hardware documentation developed at<br />

private expense. Use, reproduction, or disclosure by the Government is subject to the terms of Unisys st<strong>and</strong>ard<br />

commercial license for the products, <strong>and</strong> where applicable, the restricted/limited rights provisions of the contract data<br />

rights clauses.<br />

FCC Statement<br />

The statement below is included in this document to comply with a Federal Communications Commission (FCC)<br />

regulation. The FCC is an agency of the United States government; thus, the statement below applies to computing<br />

equipment installed in the United States of America. Unisys is taking appropriate steps to be in compliance with FCC<br />

regulations <strong>and</strong> similar regulations of other countries.<br />

WARNING: This equipment has been tested <strong>and</strong> found to comply with the limits for a Class A device, pursuant to Part<br />

15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the<br />

equipment is operated in a commercial environment. This equipment generates, uses, <strong>and</strong> can radiate radio frequency<br />

energy <strong>and</strong>, if not installed <strong>and</strong> used in accordance with the instruction manual, may cause harmful interference to radio<br />

communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case<br />

users will be required to correct the interference at their own expense.<br />

Canadian Regulatory Statement<br />

This class A apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.<br />

Cet appareil de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.<br />

Unisys <strong>and</strong> ClearPath are registered trademarks of Unisys Corporation in the United States <strong>and</strong> other countries.<br />

All other br<strong>and</strong>s <strong>and</strong> products referenced in this document are acknowledged to be the trademarks or registered<br />

trademarks of their respective holders.


ClearPath Plus Server<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>,<br />

<strong>and</strong> <strong>FS1800</strong><br />

I/O <strong>Reference</strong><br />

ClearPath Plus<br />

Server<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>,<br />

<strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />

I/O <strong>Reference</strong><br />

6871 6364–003 6871 6364–003<br />

Bend here, peel upwards <strong>and</strong> apply to spine.


Contents<br />

Section 1. Introduction<br />

Audience ............................................................................................... 1–1<br />

Prerequisites ......................................................................................... 1–1<br />

About This Document ........................................................................... 1–1<br />

Section 2. Qualified I/O Device Tables<br />

Qualified Devices .................................................................................. 2–1<br />

Section 3. SCSI Device Guidelines<br />

Introduction........................................................................................... 3–1<br />

Dual Initiator SCSI................................................................ 3–1<br />

Subsystem Configuration Guidelines.................................................... 3–2<br />

Tape Storage Subsystems Configuration Guidelines .......... 3–2<br />

DSI ALP60 Linear Tape Open (LTO) Gen2 .......................... 3–3<br />

ALP/SDLT320 Tape Subsystem .......................................... 3–3<br />

DSI ALP8700 Tape Subsystem ........................................... 3–7<br />

Section 4. Fibre Channel Device Guidelines<br />

General.................................................................................................. 4–1<br />

Qualification Status.............................................................. 4–1<br />

Configuration Guideline ....................................................... 4–2<br />

Setting Up Storage Area Network Fabrics <strong>and</strong><br />

Creating Zones ................................................................ 4–2<br />

Fibre Channel Disk Subsystems ........................................................... 4–3<br />

Guidelines for Installing the Hitachi AMS Disk Array .......... 4–3<br />

Guidelines for Installing the EuroLogic JBD2000<br />

JBOD Rack ...................................................................... 4–3<br />

Guidelines for Installing the EMC Clariion CX3 Disk<br />

Array ................................................................................ 4–4<br />

Guidelines for Installing the iQstore JBOD 4000<br />

Disk Subsystem .............................................................. 4–4<br />

CX300, CX500, <strong>and</strong> CX700 Open Storage RAID<br />

Subsystem Configuration Guidelines .............................. 4–7<br />

Fibre Channel Tape Subsystems .......................................................... 4–7<br />

CTS9840 Fibre Channel Tape Configuration........................ 4–7<br />

CTS9840B Fibre Channel Tape Configuration<br />

Guidelines........................................................................ 4–8<br />

6871 6364–003 iii


Contents<br />

CTS9840C Fibre Channel Tape Configuration<br />

Guidelines ........................................................................4–8<br />

Fibre Channel Linear Tape-Open (LTO) Gen2 Tape<br />

Drive for CLU <strong>Libra</strong>ries.....................................................4–9<br />

DSI2000/4000 Tape <strong>Libra</strong>ry System...................................4–10<br />

Brocade Fibre Channel Switches.........................................................4–12<br />

Appendix A. Host Bus Adapter Cables<br />

SCSI Host Bus Port............................................................................... A–1<br />

Fibre Channel........................................................................................ A–1<br />

DB9-to-DB9 Cables ............................................................. A–1<br />

DB9-to-HSSDC Cables ........................................................ A–2<br />

HSSDC-to-HSSDC Cables ................................................... A–3<br />

HSSDC–2-to-DB9 Cables .................................................... A–3<br />

HSSDC-to-HSSDC–2 Cables ............................................... A–4<br />

LC-to-SC, 1 Gb Shortwave Optical Cables .......................... A–4<br />

LC-to-LC, Fibre Channel Optical Cables .............................. A–5<br />

Longwave Cables ................................................................ A–5<br />

Monitor, Keyboard, <strong>and</strong> Mouse ............................................................ A–5<br />

LAN....................................................................................................... A–6<br />

Index ............................................................................................. 1<br />

iv 6871 6364–003


Figures<br />

3–1. Appliance Cabling – Dual Initiator Configuration with two Tape<br />

Appliances ..................................................................................................... 3–2<br />

6871 6364–003 v


Figures<br />

vi 6871 6364–003


Tables<br />

2–1. System Options ................................................................................................. 2–3<br />

2–2. SCSI Tape Drives <strong>and</strong> <strong>Libra</strong>ries.......................................................................... 2–9<br />

2–3. Storage Area Network (SAN) Fibre Channel Disks .......................................... 2–16<br />

2–4. SAN Fibre Channel Solid State Disks............................................................... 2–25<br />

2–5. SAN Fibre Channel Tape Drives <strong>and</strong> <strong>Libra</strong>ries ................................................. 2–27<br />

2–6. SAN Fibre Channel Switches ........................................................................... 2–37<br />

3–1. Minimum Requirements for ALP60 ................................................................... 3–3<br />

3–2. Minimum ClearPath System Software Required for DSI ALP320<br />

<strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.............................................................................. 3–4<br />

3–3. DSI ALP320 Styles............................................................................................. 3–5<br />

3–4. SCSI-2W (Wide) Cable Styles for ALP320 ......................................................... 3–5<br />

3–5. Minimum ClearPath System Software Required for STK SDLT320<br />

<strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.............................................................................. 3–6<br />

3–6. SDLT320 Styles.................................................................................................. 3–6<br />

3–7. SCSI-2W (Wide) Cable Styles for DLP320 ......................................................... 3–7<br />

3–8. SCSI-2W (Wide) Cable Styles for ALP8700 ....................................................... 3–7<br />

4–1. FC3-IOP Configuration Guidelines ..................................................................... 4–2<br />

4–2. Minimum Software Levels for Configuring a AMS Disk Array .......................... 4–3<br />

4–3. Minimum Software Levels for Configuring a JBOD2000 .................................. 4–3<br />

4–4. Minimum Software Levels for Configuring a CX3 Disk Array............................ 4–4<br />

4–5. Minimum Software Levels for Configuring a iQstore JBOD 4000 Disk<br />

Subsystem..................................................................................................... 4–5<br />

4–6. Minimum Software Levels for Configuring a CX300, CX500, or CX700<br />

on a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> ......................................................................................... 4–7<br />

4–7. Minimum Software Levels for Configuring a CTS9840C on a <strong>Libra</strong>s<br />

<strong>680</strong>/<strong>690</strong>.......................................................................................................... 4–8<br />

4–8. Minimum Software Levels for Configuring a LTO Gen2 on a <strong>Libra</strong><br />

<strong>680</strong>/<strong>690</strong>.......................................................................................................... 4–9<br />

4–9. Minimum Software Levels for Configuring a DSI2000/4000 Tape<br />

<strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>................................................................. 4–10<br />

4–10. <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> System Software Levels for Operation with Brocade<br />

Switches ...................................................................................................... 4–12<br />

4–11. Qualified Brocade Switch Firmware Levels..................................................... 4–13<br />

4–12. Qualified Storage Device Firmware Levels...................................................... 4–14<br />

A–1. Fibre Channel Copper Interface Cables .............................................................A–1<br />

A–2. DB9-to-HSSDC Fibre Channel Interface Cables.................................................A–2<br />

A–3. HSSDC-to-HSSDC Fibre Channel Interface Cables............................................A–3<br />

A–4. HSSDC–2-to-DB9 Fibre Channel Interface Cables.............................................A–3<br />

A–5. HSSDC to HSSDC–2 Fibre Channel Interface Cables........................................A–4<br />

A–6. LC-to-SC Shortwave Optical Interface Cables ...................................................A–4<br />

A–7. LC-to-LC Fibre Channel Optical Interface Cables...............................................A–5<br />

6871 6364–003 vii


Tables<br />

A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables ............................................................. A–5<br />

A–9. LAN Cables ........................................................................................................ A–6<br />

viii 6871 6364–003


Section 1<br />

Introduction<br />

Audience<br />

This guide presents the specific style definitions <strong>and</strong> configuration information needed<br />

by the Sales, Sales <strong>Support</strong>, <strong>and</strong> U-ACT organizations to effectively process an initial<br />

Unisys ClearPath Plus <strong>Libra</strong> Model <strong>680</strong>/<strong>690</strong> system level order <strong>and</strong> subsequent<br />

upgrades.<br />

This guide also provides information to assist individuals responsible for defining <strong>and</strong><br />

configuring the input/output (I/O) subsystem of the server, while taking into<br />

consideration future expansion <strong>and</strong> maximum throughput.<br />

The audience for this guide includes:<br />

Prerequisites<br />

• Unisys sales personnel<br />

• Unisys sales support personnel<br />

• Unisys service representatives<br />

This guide assumes a working knowledge of large-scale computer systems.<br />

About This Document<br />

The information in this guide is contained in the following sections:<br />

Section 1 - Introduction – provides an overview of the document.<br />

Section 2 – Qualified I/O Device Tables – A matrix of all peripheral <strong>and</strong> I/O devices<br />

supported on the ClearPath <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong>. Included are related interface <strong>and</strong><br />

firmware information.<br />

Section 3 – SCSI Device Guidelines – covers SCSI tape appliance <strong>and</strong> storage<br />

device subsystems that can be migrated using this appliance. Information provided<br />

includes configuration examples, cabling, minimum device <strong>and</strong> system firmware<br />

requirements, <strong>and</strong> operational restrictions.<br />

6871 6364–003 1–1


Introduction<br />

Section 4 – Fibre Channel Device Guidelines – covers the FC3-IOP <strong>and</strong> the<br />

storage systems supported. Information provided includes configuration examples,<br />

cabling, minimum device <strong>and</strong> system firmware requirements, <strong>and</strong> operational<br />

restrictions.<br />

Appendix A – Host Bus Adapter Cables – lists of available SCSI, Fibre Channel,<br />

Ethernet, <strong>and</strong> various other system cables.<br />

1–2 6871 6364–003


Section 2<br />

Qualified I/O Device Tables<br />

Qualified Devices<br />

This section provides reference information for all I/O devices qualified by Unisys for use<br />

on the ClearPath <strong>680</strong> <strong>and</strong> <strong>690</strong> enterprise servers. This information is presented in tabular<br />

format to enable you to quickly access the following:<br />

• System Options (non-storage related options)<br />

• SCSI Tape Storage Devices<br />

• Fibre Channel Disk Storage Devices<br />

• SAN Fibre Channel Solid State Disks<br />

• Fibre Channel Tape Storage Devices<br />

• Fibre Channel Switches<br />

6871 6364–003 2–1


Qualified I/O Device Tables<br />

2–2 6871 6364–003


Qualified I/O Device Tables<br />

Table 2–1. System Options<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

Crypto Co-Processor<br />

Q F<br />

1U device<br />

CS firmware device<br />

Software is bundled. 2<br />

Max per cell. Max per<br />

system * (on 16x).<br />

RM1-CCP<br />

Q E<br />

Secure Maintenance Device<br />

1U rack mount Secure 1 per rack, provides a secure path for remote support of the<br />

Maintenance Device LM<strong>680</strong>/<strong>690</strong>, included in base package.<br />

RM125-SDT<br />

Q E<br />

Converter – Bisync to TCPIP<br />

1U, 4 Ports, rack mounted<br />

Style RM1004-CNV must also be ordered, qty = 1<br />

Style includes power cords <strong>and</strong> Ethernet cable<br />

Rack mounted, 4-port<br />

converter, Bisync to<br />

TCPIP<br />

RM1004-CN1<br />

Installation kit, Bisync to<br />

TCPIP converter<br />

RM1004-CNV<br />

6871 6364–003 2–3


Qualified I/O Device Tables<br />

ePortal Hardware<br />

Requires at least one dedicated Ethernet connection. Requires<br />

(2) 10BaseT cables for connection. Select from:<br />

DSH6OOOO3-TBT, 3m LAN cable<br />

DSH6OOOO4-TBT, 4m LAN cable<br />

DSH6OOOO7-TBT, 7m LAN cable<br />

Non-redundant option<br />

Requires software as follows:<br />

<strong>Libra</strong> <strong>680</strong>:<br />

Rack mounted base<br />

unit, 4U Enterprise<br />

Portal, 1 controller, 1<br />

Webserver blade, 1<br />

switch<br />

Q E<br />

1 CS10-MS CP ePortal Manager<br />

RMW4-BAS<br />

1 CS10-WM CP ePortal Web/Mobile Mod or<br />

1 CS10-WS CP ePortal Web Services Mod<br />

The limit is determined<br />

by the number of<br />

licensed networking<br />

ports (requires license<br />

key)<br />

<strong>Libra</strong> <strong>690</strong>:<br />

1 CS10-MSE CP ePortal Manager OE <strong>and</strong><br />

1 CS10-WME CP ePortal Web/Mobile OE <strong>and</strong>/or<br />

1 CS10-WSE CP ePortal Web Services OE<br />

2–4 6871 6364–003


Qualified I/O Device Tables<br />

ePortal Hardware<br />

Requires at least one dedicated Ethernet connection. Requires<br />

(2) 10BaseT cables for connection. Select from:<br />

DSH6OOOO3-TBT, 3m LAN cable<br />

DSH6OOOO4-TBT, 4m LAN cable<br />

DSH6OOOO7-TBT, 7m LAN cable<br />

Requires software as follows:<br />

<strong>Libra</strong> <strong>680</strong>:<br />

1 CS10-MS CP ePortal Manager<br />

2 CS10-WM CP ePortal Web/Mobile Mod or<br />

2 CS10-WS CP ePortal Web Services Mod<br />

Rack mounted 4U<br />

Enterprise Portal<br />

platform, 1 controller<br />

blade, 2 Webserver<br />

blades, 2 switches<br />

Q E<br />

or<br />

Optionally can add 3<br />

additional RMW4-PRCs.<br />

The limit is determined<br />

by the number of<br />

licensed networking<br />

ports (requires license<br />

key).<br />

RMW4-SVR<br />

1 CS10-WM CP ePortal Web/Mobile Mod <strong>and</strong><br />

1 CS10-WS CP ePortal Web Services Mod<br />

<strong>Libra</strong> <strong>690</strong>:<br />

1 CS10-MSE CP ePortal Manager<br />

2 CS10-WME CP ePortal Web/Mobile Mod or<br />

2 CS10-WSE CP ePortal Web Services Mod<br />

or<br />

1 CS10-WME CP ePortal Web/Mobile Mod <strong>and</strong><br />

1 CS10-WSE CP ePortal Web Services Mod<br />

6871 6364–003 2–5


Qualified I/O Device Tables<br />

ePortal Hardware<br />

Requires at least one dedicated Ethernet connection. Requires<br />

(2) 10BaseT cables for connection. Select from:<br />

DSH6OOOO3-TBT, 3m LAN cable<br />

DSH6OOOO4-TBT, 4m LAN cable<br />

DSH6OOOO7-TBT, 7m LAN cable<br />

Requires software as follows:<br />

Q E<br />

<strong>Libra</strong> <strong>680</strong>:<br />

Add-on board, Includes<br />

1 blade, no controller<br />

RMW4-PRC<br />

1 CS10-WM CP ePortal Web/Mobile Mod or<br />

1 CS10-WS CP ePortal Web Services Mod<br />

<strong>Libra</strong> <strong>690</strong>:<br />

1 CS10-WME CP ePortal Web/Mobile Mod or<br />

1 CS10-WSE CP ePortal Web Services Mod<br />

2–6 6871 6364–003


Qualified I/O Device Tables<br />

ePortal Hardware<br />

Requires at least one dedicated, licensed, Ethernet connection.<br />

Requires (2) GS516-T16 when 2 or more RMW4-ADD are<br />

ordered.<br />

Requires (2) 10BaseT cables for connection. Select from:<br />

DSH6OOOO3-TBT, 3m LAN cable<br />

DSH6OOOO4-TBT, 4m LAN cable<br />

DSH6OOOO7-TBT, 7m LAN cable<br />

Maximum of 5 Add-on<br />

4U chassis, each<br />

includes 1 webserver<br />

blade, 2 switches<br />

Q E<br />

RMW4-ADD<br />

<strong>Libra</strong> <strong>680</strong>:<br />

1 CS10-WM CP ePortal Web/Mobile Mod or<br />

1 CS10-WS CP ePortal Web Services Mod<br />

Does not require a<br />

controller blade.<br />

Optionally add 4<br />

additional RMW4-PRCs<br />

<strong>Libra</strong> <strong>690</strong>:<br />

1 CS10-WM CP ePortal Web/Mobile Mod or<br />

1 CS10-WS CP ePortal Web Services Mod<br />

<strong>Libra</strong> <strong>680</strong>:<br />

1 CS10-MS CP ePortal Manager<br />

Add-on controller blade.<br />

Used for cold spare<br />

only, not installed until<br />

needed<br />

RWM4-MGR<br />

<strong>Libra</strong> <strong>690</strong>:<br />

1 CS10-MSE CP ePortal Manager OE<br />

6871 6364–003 2–7


Qualified I/O Device Tables<br />

ePortal Hardware<br />

This style is used to add a second switch to the RMW4-BAS,<br />

no software required<br />

Add-on 10/100 Ethernet<br />

switch<br />

Used on RMW4-BAS for<br />

redundancy<br />

RMW4-SWT<br />

Requires 2 GS516-T16 when a second RMW4-ADD is<br />

configured<br />

GS516-T16 Gigabit switch, 16 Ports<br />

FC3-IOP<br />

PCI networking /<br />

storage solution; (1) GE<br />

network tap GE (copper<br />

or optical capable); (2)<br />

storage taps (optical<br />

only; 1 GB, 2GB, 4GB<br />

capable)<br />

PCA NH_FC<br />

Serial Attached SCSI Feature<br />

PCI based Boot / ODT<br />

solution<br />

PCA NH_SAS<br />

2–8 6871 6364–003


Qualified I/O Device Tables<br />

Table 2–2. SCSI Tape Drives <strong>and</strong> <strong>Libra</strong>ries<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

SCSI Tape Appliance<br />

Q F<br />

Requires one CSH 10<strong>680</strong>-IOL or CSH 10<strong>690</strong>-IOL per<br />

SCSI Tape Appliance<br />

The SCSI Tape<br />

Appliance Package style<br />

is RM10x0-SCI, it<br />

supports three (3) High<br />

Voltage Differential<br />

(HVD) SCSI ports for<br />

use in SCSI-based tape<br />

migrations. Each<br />

RM10x0-SCI requires an<br />

IO key. The number of<br />

RM1-SCI is limited to<br />

the number of available<br />

FC ports (Total system<br />

maximum is 8).<br />

RM1010-SCI (factory<br />

installed)<br />

RM1020-SCI (field<br />

installed)<br />

6871 6364–003 2–9


Qualified I/O Device Tables<br />

DSI DLT320 Tape<br />

Drive<br />

DSI SDLT320 Rack<br />

Mount Tape Drive,<br />

SCSI- High Voltage<br />

Differential (HVD)<br />

HVD Drive<br />

ALP320<br />

M SA<br />

Note: Low Voltage Differential (LVD) drives are not supported.<br />

ALP320 –RDD<br />

M SA<br />

DSI ALP320 HVD 2<br />

Drive Rack Mount Kit<br />

(Dual Buss)<br />

HVD Drive<br />

ALP3202 -RMK<br />

M SA<br />

DSI ALP320 8-Cart<br />

w/Rack Kit HVD 3U<br />

HVD Drive<br />

ALP320-RVD<br />

Cable<br />

M SA<br />

CBL133-XX. Up to 80 feet.<br />

CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />

ADP 133-FMF for concatenation<br />

DSI ALP320 –<br />

Removable 8-Cartridge<br />

w/Rack Kit<br />

HVD Drive<br />

ALP320-RAD<br />

Partition Information<br />

M SA<br />

DSI ALP320 –<br />

Removable 16-Cart<br />

w/Rack Kit<br />

HVD Drive<br />

ALP320-RSD<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

M SA<br />

DSI ALP320 –<br />

Removable 16-Cart<br />

w/Rack Kit, HVD w/SW<br />

HVD Drive<br />

ALP320-RTD<br />

M SA<br />

ALP320 -TDD DSI SDLT320 Single<br />

Tape Drive, Table Top<br />

SCSI-HVD<br />

HVD Drive<br />

2–10 6871 6364–003


Qualified I/O Device Tables<br />

DSI LTO Gen2 Tape<br />

Unit<br />

HVD Removable 8-Cart<br />

ACL, 3U<br />

ALP60<br />

M SA<br />

ALP60-RAD<br />

Firmware Level: F49Z<br />

HVD Rack mount Drive<br />

Kit<br />

M SA<br />

Cable<br />

ALP60-RDD<br />

CBL133-XX. Up to 80 feet.<br />

CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />

ADP 133-FMF for concatenation<br />

Firmware Level: F4AD<br />

HVD Removable 8-Cart<br />

ACL, 3U<br />

M SA<br />

ALP60-RSD<br />

Partition Information<br />

Firmware Level: F49Z<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

HVD Removable 16-Cart<br />

ACL, 2U w/Man<br />

M SA<br />

ALP60-RTD<br />

Firmware Level: F49Z<br />

HVD St<strong>and</strong>alone Drive<br />

M SA<br />

ALP60-TDD<br />

Firmware Level: F4AD<br />

6871 6364–003 2–11


Qualified I/O Device Tables<br />

SDLT320 Tape Drive<br />

for STK Cartridge<br />

Tape <strong>Libra</strong>ries<br />

CLU180 - SDLT320<br />

Tape Drive, SCSI-HVD<br />

CLUxxx-D3S.<br />

M SA<br />

Cable<br />

CLU180-D3S<br />

M SA<br />

CBL133-XX. Up to 80 feet.<br />

CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />

ADP 133-FMF for concatenation<br />

CLU201 - SDLT320<br />

Tape Drive, SCSI-HVD<br />

CLU201-D3S<br />

Partition Information<br />

CLU700-D3S CLU700 - SDLT320<br />

Tape Drive, SCSI-HVD<br />

M SA<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

ALP8436<br />

M SA<br />

DSI 36-track tabletop<br />

tape drive<br />

ALP8436-TDD<br />

M SA<br />

Cable<br />

DSI 36-track rack single<br />

mount tape drive<br />

ALP8436-RD<br />

M SA<br />

CBL133-XX. Up to 80 feet.<br />

CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />

ADP 133-FMF for concatenation<br />

DSI 36-track, 10cartridge<br />

autoloader,<br />

tabletop<br />

ALP8436-TAS<br />

Partition Information<br />

M SA<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

DSI 36-track, 10cartridge<br />

autoloader,<br />

rack mount<br />

ALP8436-RAS<br />

M SA<br />

DSI 36-track dual (1<br />

drive <strong>and</strong> 10-cartridge)<br />

autoloader, rack mount<br />

ALP8436-RAD<br />

2–12 6871 6364–003


Qualified I/O Device Tables<br />

OST5136 Tape<br />

OST5136-MTS 36 track tape drive Partition Information<br />

M SA<br />

M SA<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

One rack mount 36<br />

track drive<br />

OST5136-1D0<br />

M SA<br />

One rack mount 36<br />

track drive with one<br />

autoloader<br />

OST5136-1D1<br />

M SA<br />

Two rack mount 36<br />

track drives<br />

OST5136-2D0<br />

M SA<br />

Two rack mount 36<br />

track drives with one<br />

autoloader<br />

OST5136-2D1<br />

M SA<br />

Two rack mount 36<br />

track drives with (2)<br />

autoloaders<br />

OST5136-2D2<br />

M SA<br />

Four rack mount 36<br />

track drives with four<br />

autoloaders<br />

OST5136-44<br />

M SA<br />

19U cabinet with one 36<br />

track drive<br />

OST5136-C10<br />

M SA<br />

19U cabinet with (2) 36<br />

track drive<br />

OST5136-C20<br />

M SA<br />

19U cabinet with (2) 36<br />

track drives with<br />

autoloader<br />

OST5136-C21<br />

6871 6364–003 2–13


Qualified I/O Device Tables<br />

OST5136 Tape<br />

Continued<br />

M SA<br />

Table top 36 track tape<br />

drive<br />

OST5136-T1<br />

M SA<br />

Table top 36 track tape<br />

drive with autoloader<br />

OST5136-TLC<br />

CTS5236 Tape<br />

M SA<br />

Two 36 track controller<br />

transport units, ten<br />

cartridge capacity with<br />

autoloader<br />

CTS5236-2SA<br />

M SA<br />

Two 36 track controller<br />

transport units <strong>and</strong> a<br />

library attachment kit for<br />

CLU6000 class tape<br />

libraries<br />

CTS5236-2S6<br />

Partition Information<br />

M SA<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

Two 36 track controller<br />

transport units <strong>and</strong> a<br />

library attachment kit for<br />

CLU1000 class tape<br />

libraries<br />

CTS5236-2S1<br />

M SA<br />

Four 36 track controller<br />

transport units <strong>and</strong> a<br />

library attachment kit for<br />

CLU6000 class tape<br />

libraries<br />

CTS5236-4S6<br />

M SA<br />

Four 36 track controller<br />

transport units <strong>and</strong> a<br />

library attachment kit for<br />

CTS5236-4S1<br />

2–14 6871 6364–003


Qualified I/O Device Tables<br />

CLU1000 class tape<br />

libraries<br />

CTS9840 Tape<br />

CTS9840-SD9 Single cartridge drive M SA<br />

CTS9840-SDL Single cartridge drive M SA<br />

CTS9840-SLL L SERIES M SA<br />

Single CTS9840 manual<br />

CTS9840-SR1<br />

M SA<br />

rack<br />

Partition Information<br />

Dual CTS9840 manual<br />

CTS9840-SR2<br />

M SA<br />

rack<br />

Control: MT1SCSI<br />

Unit Type: MT<br />

CTS9840-SRA Rack mount autoloader M SA<br />

M SA<br />

Rack mount manual<br />

loader<br />

CTS9840-SRM<br />

CTS9840-STA Table top autoloader M SA<br />

M SA<br />

CTS9840-STM Table top<br />

6871 6364–003 2–15


Qualified I/O Device Tables<br />

Table 2–3. Storage Area Network (SAN) Fibre Channel Disks<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

AMS Disk Array<br />

Q F<br />

Note: Peripheral Test Driver not supported.<br />

AMS200 AMS 200 Array Solution<br />

Q F<br />

Partition Information<br />

AMS500 (DF700M) AMS 500 Array Solution<br />

Q F<br />

Control: FC2 FCSCSI1 Unit Type: PK<br />

AMS1000 (DF700H) AMS 1000 Array Solution<br />

2–16 6871 6364–003


Qualified I/O Device Tables<br />

HDS USP Tagmastore <strong>and</strong> 9500 Thunder<br />

RAID Disk Array<br />

USP 100 Tagmastore Entry Cable<br />

Q F<br />

USP 600 Tagmastore Enhanced CBL171-xx<br />

Q F<br />

USP 1100 Tagmastore High End Protocol<br />

Q F<br />

9570V Thunder High End Fabric <strong>and</strong> arbitrated loop modes. No mixing of control types on Q F<br />

the same arbitrated loop. Quickloop connections are not<br />

9580V Thunder Ultra High End supported.<br />

Q F<br />

For Fabric connected configurations, the relationship of one<br />

9585V Thunder Ultra High End channel to up to two units should be maintained <strong>and</strong> it is<br />

recommended that they be placed in a zone. If more channels<br />

<strong>and</strong> units are attached to the same fabric they should each be<br />

in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be<br />

designed to h<strong>and</strong>le the additional units <strong>and</strong> channels.<br />

The use of 300GB-10 FC in the USP <strong>and</strong> the 250 GB SATA<br />

drives in the 9500 are restricted for use, due to the possibility<br />

of IO timeouts<br />

Q F<br />

Partition Information<br />

Control: FC2 FCSCSI1 Unit Type: PK<br />

6871 6364–003 2–17


Qualified I/O Device Tables<br />

M F<br />

Host-based mirroring required<br />

ESM7900 Fibre<br />

Channel Disk<br />

OSD18201-F96 18GB FC 520<br />

bytes/sector 10K<br />

M F<br />

Includes equivalent CSM7900 models.<br />

Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />

for fibre conversion.<br />

36GB FC, 520<br />

Bytes/sector 10K<br />

OSC36202-F94<br />

Protocols<br />

OSC73203-F94 73 GB FC, 520<br />

Bytes/sector 10K<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

M F<br />

Partition Information<br />

Control: FC2 OSRCTL<br />

Unit Type: PK<br />

EuroLogic JBD2000<br />

JBOD<br />

Cable<br />

M F<br />

CBL171-xx<br />

JBD2000 High<br />

Availability Enclosure,<br />

Dual Optical/Copper I/O<br />

Modules.<br />

JBD2022-HA<br />

Protocol<br />

M F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

JBD2000 High<br />

Availability Enclosure,<br />

Dual Optical/Optical I/O<br />

Modules<br />

JBD2040-HA<br />

Partition Information<br />

M F<br />

Control: FC2 FCSCSI1<br />

JBD2000 High<br />

Availability Expansion<br />

Enclosure, Dual<br />

Copper/Copper I/O<br />

Modules<br />

JBD2004-HA<br />

2–18 6871 6364–003


Qualified I/O Device Tables<br />

Unit Type: PK<br />

M F<br />

JBD2000 St<strong>and</strong>ard<br />

Availability Enclosure,<br />

Single Optical/Copper<br />

I/O Module<br />

JBD2011-SA<br />

M F<br />

St<strong>and</strong>ard Availability<br />

Enclosure, Single<br />

Optical/Optical I/O<br />

Module<br />

JBD2020-SA<br />

M F<br />

St<strong>and</strong>ard Availability<br />

Expansion Enclosure,<br />

Single Copper/Copper<br />

I/O Module<br />

JBD2002-SA<br />

EuroLogic JBD2000<br />

JBOD<br />

M F<br />

18GB 15K RPM disk,<br />

Factory Installed<br />

JBD201815-2F<br />

Cable<br />

M F<br />

CBL171-xx<br />

18GB 15K RPM disk,<br />

Field Upgrade<br />

JBD201815-2U<br />

M F<br />

Protocol<br />

36GB 15K RPM disk,<br />

Factory Installed<br />

JBD201815-2F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

M F<br />

Partition Information<br />

36GB 15K RPM disk,<br />

Field Upgrade<br />

JBD203615-2U<br />

M F<br />

Control: FC2 FCSCSI1<br />

2000 36GB 10K RPM<br />

disk, Factory Installed<br />

JBD203610-2F<br />

Unit Type: PK<br />

M F<br />

36GB 10K RPM disk,<br />

Field Upgrade<br />

JBD203610-2U<br />

6871 6364–003 2–19


Qualified I/O Device Tables<br />

EMC Clariion<br />

Subsystems<br />

CX3-20 CX3-20 SPE Host based mirroring or multipath license required. Q F<br />

CX3-40 CX3-40 SPE Cable<br />

Q F<br />

CX3-80 CX3-80 SPE CBL171-xx<br />

Q F<br />

Q F<br />

Protocols<br />

73GB 15K 520 BPS 4GB<br />

12 V<br />

CX-4G15-73<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Q F<br />

Partition Information<br />

146 GB 15K 520 BPS<br />

4GB 12V<br />

CX-4G15-146<br />

Control: FC2 OSRCTL<br />

Q F<br />

CX300 Fibre Channel<br />

2GB<br />

CXU3001-DPE<br />

Unit Type: PK<br />

Host based mirroring or multipath license required.<br />

Q F<br />

The CLARiiON CX300 is<br />

an entry-level member<br />

of the EMC CLARiiON<br />

CX series.<br />

CX300<br />

Cable<br />

CBL171-xx<br />

Q F<br />

Protocols<br />

The CLARiiON CX500 is<br />

a mid-level member of<br />

the EMC CLARiiON CX<br />

series.<br />

CX500<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Partition Information<br />

Q F<br />

Control: FC2 OSRCTL<br />

The CLARiiON CX700 is<br />

a high-end member of<br />

the EMC CLARiiON CX<br />

series.<br />

CX700<br />

Unit Type: PK<br />

Host based mirroring required.<br />

M F<br />

CX400 The CLARiiON CX400 is<br />

a mid-level member of<br />

2–20 6871 6364–003


Qualified I/O Device Tables<br />

Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />

for fibre conversion.<br />

the EMC CLARiiON CX<br />

series.<br />

Protocols<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

M F<br />

Partition Information<br />

The CLARiiON CX600 is<br />

a high-end member of<br />

the EMC CLARiiON CX<br />

series<br />

CX600<br />

Control: FC2 OSRCTL<br />

Unit Type: PK<br />

EMC Symmetrix<br />

Disk<br />

Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />

for fibre conversion.<br />

Protocols<br />

M F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

CAB82xx, CAB84xx,<br />

CAB85xx, CAB87xx <strong>and</strong><br />

CAB88xx Styles<br />

Symmetrix 5.0 <strong>and</strong> 5.5<br />

Partition Information<br />

Control: FC2 FCPK1EMC<br />

Unit Type: PK<br />

6871 6364–003 2–21


Qualified I/O Device Tables<br />

EMC DMX<br />

Symmetrix Series<br />

Disk Subsystem<br />

DMX800 Rack mount Q F<br />

DMX801 Rack mount Q F<br />

Q F<br />

Single cabinet. Includes<br />

models DMX1000,<br />

DMX1000-P2 <strong>and</strong><br />

DMX1000-M2<br />

DMX1000<br />

Protocols<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Partition Information<br />

Dual cabinet. Includes<br />

models DMX2000,<br />

DMX2000-P2,<br />

DMX2000-M2,<br />

DMX2000-3 (3-phase),<br />

DMX2000-P2-3 (3phase)<br />

<strong>and</strong> DMX2000-<br />

M2-3 (3-phase).<br />

DMX2000<br />

Control: FC2 FCPK1EMC<br />

F<br />

Q<br />

Unit Type: PK<br />

Q F<br />

Includes models<br />

DMX3000-3 (3-phase)<br />

<strong>and</strong> DMX3000-M2-3 (3phase).<br />

DMX3000<br />

Q F<br />

DMX1500 DMX3 Array Note: Peripheral Test Driver not supported<br />

2–22 6871 6364–003


Qualified I/O Device Tables<br />

DMX2500 DMX3 Array Q F<br />

DMX3500 DMX3 Array Partition Information<br />

Q F<br />

Control: FC2 FCPK1EMC<br />

Q F<br />

DMX4500 DMX3 Array<br />

Unit Type: PK<br />

6871 6364–003 2–23


Qualified I/O Device Tables<br />

Q F<br />

iQstor JBOD 4000<br />

JBD4000 RTS4001<br />

Factory Ship Drop Ship<br />

Styles Styles<br />

Q F<br />

Peripheral Test Driver<br />

Not <strong>Support</strong>ed<br />

4 gigabit FC base<br />

storage enclosure<br />

RTS412880-<br />

BAS<br />

JBD4000-<br />

BAS<br />

36 gigabyte 15K RPM<br />

4Gbit FC drive<br />

Q F<br />

Cable<br />

RTS4303615-<br />

4F<br />

JBD403615-<br />

4F<br />

CBL171-xx<br />

Protocol<br />

Q F<br />

73 gigabyte 15K RPM<br />

4Gbit FC drive<br />

RTS4307314-<br />

4F<br />

JBD407315-<br />

4F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Q F<br />

Partition Information<br />

146 gigabyte 15K<br />

RPM 4Gbit FC drive<br />

RTS4314615-<br />

4F<br />

JBD4014615-<br />

4F<br />

Control: FC2 FCSCSI1<br />

Q F<br />

Unit Type: PK<br />

Rack-mount kit for<br />

J2880<br />

RTS400012-<br />

RK<br />

JBD4000-<br />

RMK<br />

Q F<br />

FC4 optical SFP<br />

transceiver,<br />

850nm,LC<br />

RTS400150-<br />

SFP<br />

JBD4010-IF<br />

2–24 6871 6364–003


Qualified I/O Device Tables<br />

Table 2–4. SAN Fibre Channel Solid State Disks<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

DSI2100 Solid State Disk<br />

DSI2100-08 8GB unit, 1Gb interface M F<br />

Protocol<br />

M F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

16GB unit, 1Gb<br />

interface<br />

DSI2100-016<br />

Partition Information<br />

M F<br />

24GB unit, 1Gb<br />

interface<br />

DSI2100-24<br />

Control: FC2 FCPK1SCSI<br />

Unit Type: PK M F<br />

32GB unit, 1Gb<br />

interface<br />

DSI2100-032<br />

6871 6364–003 2–25


Qualified I/O Device Tables<br />

Q F<br />

DSI3200/DSI3250 Solid State Disk<br />

16 GB System, Unisys<br />

DSI3200-U16<br />

38271<strong>680</strong>-000DSI PN<br />

04DSI3200-U16<br />

Q F<br />

32 GB System, Unisys<br />

38271706-000DSI PN<br />

04DSI3200-U32<br />

DSI3200-U32<br />

Q F<br />

Protocol<br />

48 GB System, Unisys<br />

38271714-000DSI PN<br />

04DSI3200-U48<br />

DSI3200-U48<br />

Fabric <strong>and</strong> arbitrated loop modes<br />

Q F<br />

Partition Information<br />

64GB System, Unisys<br />

38271722-000DSI PN<br />

04DSI3200-U64<br />

DSI3200-U64<br />

Control: FC2 FCPK1SCSI<br />

Q F<br />

Unit Type: PK<br />

8 GB System, ITI<br />

38361465-000DSI PN<br />

04DSI3208-ITI<br />

DSI3208-ITI<br />

Q F<br />

16GB Exp Module<br />

38361515-000DSI PN<br />

04DSI32U16-MEM<br />

DSI3216-MEM<br />

Q F<br />

Dual Port 2GB FC<br />

interface 38361523-<br />

000DSI PN<br />

04DSI32U65-FC<br />

DSI3265-FC<br />

2–26 6871 6364–003


Qualified I/O Device Tables<br />

Table 2–5. SAN Fibre Channel Tape Drives <strong>and</strong> <strong>Libra</strong>ries<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

ALP360 SDLT<br />

Note: Low Voltage Differential (LVD) drives are not supported<br />

Cable<br />

CBL171-xx<br />

Protocols<br />

Q F<br />

Single SDLT600<br />

Rackmount FC, single<br />

node<br />

ALP360-1FS<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Partition Information<br />

Control = FC2 FCSCSIMT<br />

Unit Type: MT<br />

6871 6364–003 2–27


Qualified I/O Device Tables<br />

ALP360 SDLT<br />

Restrictions<br />

Mixing of ALP360 <strong>and</strong> other fibre channel control types on the same attach<br />

Loop is not allowed <strong>and</strong> restricted.<br />

Quickloop connections are not supported.<br />

It is the expected behavior of Fibre Channel tape units to report irrecoverable<br />

I/Os if a LIP (Loop Initialization Process) occurs after data transfer has started<br />

for either a read or write operation between the device <strong>and</strong> the host channel.<br />

If data transfer has not started between the device <strong>and</strong> the host channel, the<br />

I/O reporting the LIP as an outboard bus device reset will be retried.<br />

Q F<br />

For Fabric connected configurations, the relationship of one channel to up to<br />

two units should be maintained <strong>and</strong> it is recommended that they be placed in a<br />

zone. If more channels <strong>and</strong> units are attached to the same fabric they should<br />

each be in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to<br />

h<strong>and</strong>le the additional units <strong>and</strong> channels.<br />

Dual SDLT600<br />

Rackmount, FC, dual<br />

node<br />

ALP360-2FD<br />

The ALP360 does not utilize a Hard Addressing scheme for connection to<br />

FC_AL arbitrated loop. This device uses a Soft address scheme that starts the<br />

process of obtaining a loop address (soft) at the low end of the AL_PA table of<br />

AL_PA’s (i.e. starting at AL_PA =EF dec. 00). Based on this, the ALP360<br />

must be the only target device on the FC_AL to the host initiator when direct<br />

connect FC_AL mode is configured. And can only be configured using address<br />

0 for the control in a direct attach configuration. When using this device in a<br />

fabric configuration the WWID Port Name should be used in the configuration<br />

file.<br />

ALP360-RFD SDLT600 field upgrade,<br />

ALP360-1FS to ALP360-<br />

2FD<br />

2–28 6871 6364–003


Qualified I/O Device Tables<br />

CTS7840 Fibre<br />

Channel Tape<br />

Single drive for<br />

Protocol<br />

CTS7840-FDL<br />

M F<br />

CLU6000<br />

Arbitrated loop mode only<br />

CTS7840-FLL Single drive for CLU700 M F<br />

Partition Information<br />

CTS7840-FR1 FC rack, single M F<br />

Control = FC2 FCSCSIMT<br />

CTS7840-FR2 FC rack, dual<br />

M F<br />

Unit Type: MT<br />

CTS9840 Fibre<br />

Channel Tape<br />

M F<br />

Single rack mount with<br />

autoloader<br />

CTS9840-FRA<br />

M F<br />

Protocols<br />

Single drive for<br />

CLU9710<br />

CTS9840-FD9<br />

M F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Single drive for<br />

CLU9740 <strong>and</strong> CLU6000<br />

CTS9840-FDL<br />

Partition Information<br />

M F<br />

Control = FC2 FCSCSIMT<br />

Single drive for CLU180<br />

<strong>and</strong> CLU700<br />

CTS9840-FLL<br />

M F<br />

Unit Type: MT<br />

Single drive for<br />

CLU9710<br />

CTS9840-SD9<br />

M F<br />

Single drive for<br />

CLU9740 <strong>and</strong> CLU6000<br />

CTS9840-SDL<br />

6871 6364–003 2–29


Qualified I/O Device Tables<br />

CTS9840B Fibre<br />

Channel Tape<br />

M F<br />

FC Drive on<br />

CLU6000/9740 <strong>Libra</strong>ries<br />

Tray<br />

CTB9840-FDL<br />

Protocols<br />

M F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

FC Drive on<br />

CLU180/700<br />

<strong>Libra</strong>ries Tray<br />

CTB9840-FLL<br />

Partition Information<br />

M F<br />

Control = FC2 FCSCSIMT<br />

FC Drive Rack Mount<br />

Single.<br />

CTB9840-FR1<br />

M F<br />

Unit Type: MT<br />

FC Drive Rack Mount<br />

Dual<br />

CTB9840-FR2<br />

M F<br />

CTB9840-FTM FC Drive Table Top.<br />

CTB9840C Fibre<br />

Channel Tape<br />

Q F<br />

Protocols<br />

9840C FC Drive<br />

CLU9740/6000<br />

CTC9840-FDL<br />

Q F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

9840C FC Drive<br />

CLU180/700<br />

CTC9840-FLL<br />

Partition Information<br />

Q F<br />

Control = FC2 FCSCSIMT<br />

9840C FC Single rack<br />

mount Drive<br />

CTC9840-FR1<br />

Q F<br />

Unit Type: MT<br />

9840C Two RK MT<br />

Drives<br />

CTC9840-FR2<br />

2–30 6871 6364–003


Qualified I/O Device Tables<br />

CTB9940 Fibre<br />

Channel Tape<br />

Q F<br />

Protocols<br />

Drive on CLU6000/9740<br />

<strong>Libra</strong>ries Tray<br />

CTB9940-FDL<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Partition Information<br />

Q F<br />

Control = FC2 FCSCSIMT<br />

Drive on<br />

CLU180/700<strong>Libra</strong>ries<br />

Tray<br />

CTB9940-FLL<br />

Unit Type: MT<br />

Linear Tape-Open (LTO) Gen2 Tape Drive<br />

for CLU <strong>Libra</strong>ries<br />

Note: Low Voltage Differential (LVD) drives are not supported<br />

Protocols<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Q F<br />

HP LTO Gen2 drive on<br />

CLU180 tray<br />

CLU180-22F<br />

Partition Information<br />

Control = FC2 FCSCSIMT<br />

Unit Type: MT<br />

6871 6364–003 2–31


Qualified I/O Device Tables<br />

DSI2000/4000 Tape Products<br />

Note: Low Voltage Differential (LVD) drives are not supported<br />

Q F<br />

30-Cartridge Base<br />

<strong>Libra</strong>ry for LTO, LVD<br />

<strong>Libra</strong>ry Interface<br />

DSI2100-L30<br />

Protocols<br />

Q F<br />

52-Cartridge Base<br />

<strong>Libra</strong>ry for LTO, LVD<br />

library interface<br />

DSI2100-L60<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Partition Information<br />

Q F<br />

60-Cartridge Base<br />

<strong>Libra</strong>ry<br />

LTO, LVD library<br />

interface<br />

DSI4100-L60<br />

Control = FC2 FCSCSIMT<br />

Unit Type: MT<br />

Q F<br />

104-Cartridge Base<br />

<strong>Libra</strong>ry LTO, LVD library<br />

interface<br />

DSI4200-L12<br />

Q F<br />

LTO3, Native FC Drive<br />

Kit for DSI Revolution<br />

Tape <strong>Libra</strong>ry<br />

DSIF63-REV<br />

Q F<br />

FC Robotics Interface,<br />

shortwave, 2GB SFP<br />

(LTO Only<br />

DSI63-FB2<br />

Q F<br />

Partitioning Option for<br />

Revolution <strong>Libra</strong>ry<br />

DSI240-POC<br />

Q F<br />

DSI2100 to DSI2200<br />

Pass Thru Kit<br />

DSI2122-RVG<br />

Q F<br />

DSI4100 to DSI4200<br />

Pass Thru Kit<br />

DSI4142-RVG<br />

2–32 6871 6364–003


Qualified I/O Device Tables<br />

Q F<br />

DSI Fibre <strong>Libra</strong>ry<br />

Controller for use with<br />

optional DSI63-FB2 FC<br />

interface<br />

DSI1000-IPF<br />

Q F<br />

DSI LVD <strong>Libra</strong>ry<br />

Controller for use with<br />

Base Cartridge<br />

controller with LVD<br />

library interface<br />

DSI1000-IPV<br />

SUN/StorageTek FC Linear Tape-Open (LTO)<br />

Gen3 <strong>Libra</strong>ry<br />

LTO Gen3 For L180/700<br />

STK3001100-000<br />

Q F<br />

HP LTO Fibre I/F<br />

STK3001101-HPF<br />

Protocols<br />

StorageTek Label<br />

STK3001103-STK<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

LTO Gen3 Drive for<br />

SL500<br />

STK3001104-000<br />

Partition Information<br />

Q F<br />

HP LTO Fibre I/F<br />

STK3001105-HPF<br />

Control = FC2 FCSCSIMT<br />

StorageTek Label<br />

STK3001107-STK<br />

Unit Type: MT<br />

HP LTO Drive for<br />

SL8500<br />

STK3001108-000<br />

Q F<br />

HP LTO Fibre I/F<br />

STK3001109-HPF<br />

StorageTek Label<br />

STK3001110-STK<br />

6871 6364–003 2–33


Qualified I/O Device Tables<br />

Protocols<br />

Q F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

DSI Fibre Channel Linear Tape-Open (LTO)<br />

Gen2 Rack Mount Fibre Channel Tape Drive<br />

Single LTO2 Rack<br />

ALP60-1FS,<br />

mount, FC-AL Single<br />

Node<br />

Q F<br />

Partition Information<br />

Dual LTO2 Rack mount,<br />

FC-AL Dual Node<br />

ALP60-2FD<br />

Control = FC2 FCSCSIMT<br />

Q F<br />

Unit Type: MT<br />

FC, LTO2 Field<br />

Upgrade, ALP60-1FS to<br />

ALP60-2FD<br />

ALP60-RDF<br />

Protocols<br />

Q F<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

DSI Fibre Channel Linear Tape-Open (LTO)<br />

Gen2 Auto Loader Fibre Channel Tape<br />

Drive<br />

Removeable 30-<br />

ALP60-FAS<br />

Cartridge ACL, Dual<br />

LTO2 drive, FC-AL<br />

Partition Information<br />

Control = FC2 FCSCSIMT<br />

Q F<br />

Removeable 30-<br />

Cartridge ACL, single<br />

LTO2 drive, FC-AL<br />

ALP60-FAD<br />

Unit Type: MT<br />

2–34 6871 6364–003


Qualified I/O Device Tables<br />

Q F<br />

DSI Fibre Channel Linear Tape-Open (LTO)<br />

Gen3 Rack Mount Fibre Channel Tape Drive<br />

Single LTO3 Rack<br />

ALP63-1FS<br />

mount, FC-AL Single<br />

Node<br />

Q F<br />

Protocols<br />

Dual LTO3 Rack mount,<br />

FC-AL Dual Node<br />

ALP63-2FD<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

Q F<br />

Partition Information<br />

Single FC LTO3 30<br />

cartridge Autoloader<br />

ALP63-FAS<br />

Control = FC2 FCSCSIMT<br />

Q F<br />

Dual FC LTO3 30<br />

Cartridge Auto Loader<br />

FC<br />

ALP63-FAD<br />

Unit Type: MT<br />

Q F<br />

FC, LTO 3 Field<br />

Upgrade, ALP63-1FS to<br />

ALP63-2FD<br />

ALP63-FRD<br />

Q F<br />

ALP63-RDF FC, LTO 3 field upgrade<br />

6871 6364–003 2–35


Qualified I/O Device Tables<br />

STK SDLT600 Fibre Channel Tape Drive<br />

SDT600 Drive Tray for<br />

STK600601-000 CLU180/700/1400<br />

Q F<br />

Fibre Channel Interface<br />

STK600601-RFC<br />

Protocols<br />

StorageTek Label<br />

STK600601-TK0<br />

Fabric <strong>and</strong> arbitrated loop modes.<br />

SDLT600 Drive Tray for<br />

SL8500<br />

Partition Information<br />

STK600685-000<br />

Q F<br />

Control = FC2 FCSCSIMT<br />

Fibre Channel Interface<br />

STK600685-RFC<br />

Unit Type: MT<br />

Storage Tek Label<br />

STK600685-TK0<br />

SDLT600 Drive Tray for<br />

SL500<br />

STK650-000<br />

Q F<br />

Fibre Channel Interface<br />

STK650-BRF<br />

StorageTek Label<br />

STK650-STK<br />

2–36 6871 6364–003


Qualified I/O Device Tables<br />

Table 2–6. SAN Fibre Channel Switches<br />

Interface<br />

Status<br />

Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />

unknown<br />

Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />

Switch<br />

Fabric Only<br />

Fibre Channel<br />

Switch (Brocade)<br />

Brocade firmware level 5.1.0a M F<br />

Brocade 3900 - 2Gb, 32<br />

ports, SFP (Fabric only)<br />

HSC30439-S32<br />

Brocade firmware level 5.1.0a M F<br />

Brocade 12000 SAN<br />

Switch, 2Gb 2x64-Ports.<br />

Core FC fabric, SFP<br />

(Fabric only)<br />

HSC3041200-D64<br />

Brocade firmware level 5.1.0a M F<br />

Brocade 12000 SAN<br />

Switch, 2Gb 1x32-Ports.<br />

Core FC fabric, SFP<br />

(Fabric only)<br />

HSC3041200-S32<br />

Brocade firmware level 5.1.0a M F<br />

Brocade 12000 SAN<br />

Switch, 2Gb 1x64-Ports.<br />

Core FC fabric, SFP<br />

(Fabric only)<br />

HSC3041200-S64<br />

Copper SFPs are not supported on this switch. M F<br />

Brocade 3250, 2 Gb, 8<br />

ports, SFP (Fabric only)<br />

HSC3043250-FF<br />

6871 6364–003 2–37


Qualified I/O Device Tables<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 4900 32 port<br />

switch, 4 GB 0 SFPs,<br />

includes: Web Tools <strong>and</strong><br />

zoning<br />

HSC30449-S32<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 4900 64 port<br />

switch, 4GB 0 SFPs,<br />

includes: Web Tools <strong>and</strong><br />

zoning<br />

HSC30449-S64<br />

Copper SFPs are not supported on this switch. M F<br />

Brocade 3252, 2 Gb, 8<br />

ports, SFP (Fabric only)<br />

HSC3043252-VL2<br />

Copper SFPs are not supported on this switch. M F<br />

Brocade 3850, 16 ports,<br />

full fabric (Fabric only)<br />

HSC3043850-FF<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 200e switch.<br />

8 active ports, zero<br />

eport, 1 power supply,<br />

zero SFPs, serial cable,<br />

software: Web Tools,<br />

Advanced Zoning.<br />

HSC304210-S08<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 200e switch. 8<br />

active ports, full fabric, 1<br />

power supply, zero<br />

SFPs, serial cable,<br />

software: Web Tools,<br />

Advanced Zoning<br />

HSC304220-S08<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 200e switch.<br />

16 active ports, full<br />

fabric, 1 power supply,<br />

zero SFPs. Serial cable,<br />

software: Web Tools,<br />

Advanced zoning.<br />

HSC304240-S16<br />

2–38 6871 6364–003


Qualified I/O Device Tables<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 4100 16 Port<br />

Switch<br />

HSC304120-B16<br />

Brocade firmware level 5.1.0a Q F<br />

Brocade 4100 32 Port<br />

Switch<br />

HSC304140-B32<br />

Brocade firmware level 3.2.1a M F<br />

HSC30432-S08 Brocade 3200 – 2 Gb, 8<br />

ports, SFP (fabric)<br />

Brocade firmware level 3.2.1a M F<br />

Brocade 3800 - 2 Gb, 16<br />

ports, SFP (fabric)<br />

HSC30438-S16<br />

M F<br />

HSC304900-UPG 8 Port Upgrade<br />

M F<br />

Fibre Channel 1, 2, &4<br />

Gb SFP<br />

HSC50404-SFS<br />

6871 6364–003 2–39


Qualified I/O Device Tables<br />

2–40 6871 6364–003


Section 3<br />

SCSI Device Guidelines<br />

Introduction<br />

This section covers SCSI Tape Appliance <strong>and</strong> the tape devices subsystems that use the<br />

wide SCSI <strong>and</strong> Ultra wide SCSI interfaces. The maximum data transfer rate for Ultra<br />

SCSI interface is 40 MB per second.<br />

The following are some SCSI configuration rules:<br />

Dual Initiator SCSI<br />

• The maximum end-to-end length of the Ultra or Wide SCSI Bus is 25 meters (80<br />

ft)<br />

• For connectivity, the maximum number of SCSI devices per bus is four (4).<br />

• For best performance, the maximum number of SCSI devices per bus is two (2).<br />

• Both ends of the SCSI bus must be terminated, with no mid-bus terminations.<br />

• Each device on the bus must have a unique SCSI ID.<br />

A SCSI Dual Initiator configuration has two different bus masters. Dual Initiator is<br />

typically employed so that two different systems can access the same Tape drives<br />

(though not at the same time).<br />

6871 6364–003 3–1


SCSI Device Guidelines<br />

Figure 3–1. Appliance Cabling – Dual Initiator Configuration with two Tape<br />

Appliances<br />

Terminators require consideration with dual initiator. Both ends of the SCSI bus are<br />

terminated, so the second bus master must have the terminator removed. Port D on<br />

the LVD-HVD Converter has no terminator <strong>and</strong> may be attached to the middle of the bus.<br />

Subsystem Configuration Guidelines<br />

Tape Storage Subsystems Configuration Guidelines<br />

The following tape drive subsystems are qualified on some of ClearPath systems<br />

covered by this guide. See Section 2 for current qualification status.<br />

3–2 6871 6364–003


DSI ALP60 Linear Tape Open (LTO) Gen2<br />

SCSI Device Guidelines<br />

Table 3-1 list the minimum system software levels required to configure an ALP60.<br />

QUALIFIED<br />

CONFIGURATIONS<br />

SYSTEM<br />

Table 3–1. Minimum Requirements for ALP60<br />

QUALIFIED RELEASE/CHANGE LEVEL<br />

SYSTEM<br />

HARDWARE, SOFTWARE<br />

LIBRA <strong>680</strong>/<strong>690</strong> ClearPath MCP 10.1:<br />

MCP IC 051.1A.84<br />

Load-Utils IC 051.1A.16<br />

Log-Tools IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ALP/SDLT320 Tape Subsystem<br />

ClearPath MCP 11.1:<br />

MCP IC 052.1A.17<br />

Load-Utils IC 052.1A.1<br />

Log-Tools IC 052.1A.3<br />

DumpAnalyzer IC 051.1A.1<br />

CONTROL-WARE<br />

FIRMWARE<br />

MCP Platform<br />

Firmware 1.1<br />

There are two OEM vendors of SDLT320-type tape drives. DSI drives are st<strong>and</strong>-alone<br />

(either rack mount or tabletop) drives, <strong>and</strong> StorageTek (STK) drives are installed in CLU<br />

<strong>Libra</strong>ries (CLU180, CLU201, <strong>and</strong> CLU700).<br />

DSI Super Digital Linear Tape ALP320 St<strong>and</strong>-Alone Tape Drives<br />

DSI drives are delivered with V56 firmware installed to be compatible with DLT4000<br />

formatted tapes. You must contact your Unisys representative to acquire V70 firmware if<br />

you want to run multiple initiators. Future firmware upgrades may incorporate both<br />

requirements, but at present you can run one or the other, but not both.<br />

Table 3-2 lists the minimum firmware <strong>and</strong> system software levels required to operate<br />

your system with the ALP320 st<strong>and</strong> alone tape drives.<br />

6871 6364–003 3–3


SCSI Device Guidelines<br />

Table 3–2. Minimum ClearPath System Software Required for DSI<br />

ALP320 <strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware Level<br />

ClearPath MCP 10.1:<br />

MCP IC 051.1A.84<br />

Load-Utils IC 051.1A.16<br />

Log-Tools IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1:<br />

MCP IC 052.1A.17<br />

Load-Utils IC 052.1A.1<br />

Log-Tools IC 052.1A.3<br />

DumpAnalyzer IC 051.1A.1<br />

MCP Platform Firmware 1.1<br />

Table 3-3 lists the available DSI drives. See Section 3 for each drive’s qualification status.<br />

Available cable styles for use on ALP320 are listed in Table 3-4.<br />

The following is the firmware version rules:<br />

• V56 – Drive is compatible with DLT4000 (DLT20C) formatted tapes, but multiple<br />

initiator operation is restricted.<br />

• V70 – Drive can operate in a multiple initiator environment, but is not compatible<br />

with DLT4000 (DLT20C) formatted tapes.<br />

3–4 6871 6364–003


Table 3–3. DSI ALP320 Styles<br />

Drive Style Name Description<br />

SCSI Device Guidelines<br />

ALP320 –RDD SDLT320 Rack Mount Tape Drive, SCSI-HVD (PN 3826 8454-<br />

000)<br />

ALP3202 -RMK ALP320 HVD 2 Drive Rack Mount Kit (Dual Buss) (PN 3826<br />

8488-000)<br />

ALP320 -TDD SDLT320 Single Tape Drive, Table Top SCSI-HVD (PN 3826<br />

8439-000)<br />

Table 3–4. SCSI-2W (Wide) Cable Styles for ALP320<br />

Cable Style Description<br />

CBL 13304-06Y Dual Initiate cable<br />

CBL 13314-08Y Dual Initiate cable<br />

ADP 133-FMF SCSI Concatenation cable<br />

CBL133-10 SCSI Wide 10Ft (3.04M)<br />

CBL133-20 SCSI Wide 20Ft (6.09M)<br />

CBL133-40 SCSI Wide 40Ft (12.19M)<br />

CBL133-60 SCSI Wide 60Ft 18.28M)<br />

CBL133-80 SCSI Wide 80Ft (24.38M)<br />

StorageTek (STK) Super Digital Linear Tape SDLT320 <strong>Libra</strong>ry Tape<br />

Drives<br />

STK drives are delivered with V70 firmware installed <strong>and</strong> is capable of running multiple<br />

initiators. You must contact your Unisys representative to acquire V56 firmware if you<br />

want the drive to be compatible with DLT4000 formatted tapes. Future firmware<br />

upgrades may incorporate both requirements, but at present you can run one or the<br />

other, but not both.<br />

Table 3-5 lists the minimum firmware <strong>and</strong> system software levels required to operate<br />

you system with the SDLT320 library drives.<br />

6871 6364–003 3–5


SCSI Device Guidelines<br />

Table 3–5. Minimum ClearPath System Software Required for STK<br />

SDLT320 <strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware Level<br />

ClearPath MCP 10.1:<br />

MCP IC 051.1A.84<br />

Load-Utils IC 051.1A.16<br />

Log-Tools IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1:<br />

MCP IC 052.1A.17<br />

Load-Utils IC 052.1A.1<br />

Log-Tools IC 052.1A.3<br />

DumpAnalyzer IC 051.1A.1<br />

MCP Platform Firmware 1.1<br />

Table 3-6 lists the available STK drives. See Section 2 for each drive’s qualification status.<br />

Available cable styles for use on DLP320 are listed in Table 3-7.<br />

The following is the firmware version rules:<br />

• V70 – Drive can operate in a multiple initiator environment, but is not compatible<br />

with DLT4000 (DLT20C) formatted tapes.<br />

• V56 – Drive is compatible with DLT4000 (DLT20C) formatted tapes, but multiple<br />

initiator operation is restricted.<br />

Table 3–6. SDLT320 Styles<br />

Drive Style Name Description<br />

CLU180-D3S CLU180 - SDLT320 Tape Drive, SCSI-HVD (PN 68960343-<br />

000)<br />

CLU201-D3S CLU201 - SDLT320 Tape Drive, SCSI-HVD (PN 68960327-<br />

000)<br />

CLU700-D3S CLU700 - SDLT320 Tape Drive, SCSI-HVD (PN 68960368-<br />

000)<br />

3–6 6871 6364–003


Table 3–7. SCSI-2W (Wide) Cable Styles for DLP320<br />

Cable Style Description<br />

CBL 13304-06Y Dual Initiate cable<br />

CBL 13314-08Y Dual Initiate cable<br />

ADP 133-FMF SCSI Concatenation cable<br />

CBL133-10 SCSI Wide 10Ft (3.04M)<br />

CBL133-20 SCSI Wide 20Ft (6.09M)<br />

CBL133-40 SCSI Wide 40Ft (12.19M)<br />

CBL133-60 SCSI Wide 60Ft 18.28M)<br />

CBL133-80 SCSI Wide 80Ft (24.38M)<br />

DSI ALP8700 Tape Subsystem<br />

Restrictions<br />

Minimum System software <strong>and</strong> firmware levels:<br />

System Software Firmware<br />

MCP 10.1 MCP Platform Firmware 1.1<br />

MCP 11.0<br />

Table 3-8 contains the available cable styles for ALP8700.<br />

Table 3–8. SCSI-2W (Wide) Cable Styles for ALP8700<br />

Cable Style Description<br />

CBL133-10 SCSI Wide 10Ft (3.04M)<br />

CBL133-20 SCSI Wide 20Ft (6.09M)<br />

CBL133-40 SCSI Wide 40Ft (12.19M)<br />

CBL133-60 SCSI Wide 60Ft 18.28M)<br />

CBL133-80 SCSI Wide 80Ft (24.38M)<br />

SCSI Device Guidelines<br />

The ALP8700 is restricted to use in single initiator configurations only. Multi-Initiator<br />

configurations are not supported.<br />

6871 6364–003 3–7


SCSI Device Guidelines<br />

3–8 6871 6364–003


Section 4<br />

Fibre Channel Device Guidelines<br />

General<br />

FC3-IOP Fibre Channel adapters enable ClearPath hosts to interface to Fibre Channel<br />

protocol (FCP) peripherals <strong>and</strong> subsystems. FCP is defined as SCSI protocol over Fibre<br />

Channel. Peripherals are connected to a host using a serial interface on an arbitrated loop<br />

(FC_AL) or through a fabric.<br />

The FC3–IOP provides one Ethernet port connection <strong>and</strong> two Fibre Channel<br />

portconnections.<br />

The Gigabit Ethernet port provides external networking <strong>and</strong> ODT support. The<br />

portconnection can be either copper or optical at 1 Gb per second.<br />

The two Fibre Channel ports provide the interface to external I/O devices. Each of<br />

theFibre Channel ports provide an optical interface, with a transfer rate of either 1, 2, or 4<br />

Gbper second.<br />

Qualification Status<br />

Section 2 of this document lists which devices are supported on the FC3-IOP.<br />

6871 6364–003 4–1


Fibre Channel Device Guidelines<br />

Configuration Guideline<br />

Table 4–1. FC3-IOP Configuration Guidelines<br />

Area Guideline<br />

Maximum Interface<br />

Cable Length<br />

The following is the maximum uninterrupted length of<br />

each Fibre Channel cable type:<br />

Copper: 30 meters<br />

SW Laser 50 µm optical fiber: 100 meters @ 4 gigabit<br />

SW Laser 50 µm optical fiber: 300 meters @ 2 gigabit<br />

SW Laser 50 µm optical fiber: 500 meters @ 1 gigabit<br />

SW Laser 62.5 µm optical fiber: 50 meters @ 4 gigabit<br />

SW Laser 62.5 µm optical fiber: 300 meters @ 1 gigabit<br />

LW Laser 8 µm optical fiber: 10 kilometers<br />

Note: Maximum lengths may be exp<strong>and</strong>ed using<br />

Brocade’s Exp<strong>and</strong>ed Fibre Channel option.<br />

Connectivity Arbitrated Loop: The maximum number of ports on FC-AL<br />

is 126.<br />

Fabric: For a breakdown of fabric capabilities, see<br />

ClearPath Plus Servers <strong>Libra</strong> Modes <strong>680</strong> <strong>and</strong> <strong>690</strong><br />

Administration <strong>and</strong> Operations Guide.<br />

FC switch firmware All switches in a fabric must have compatible firmware<br />

levels for proper operation of the fabric. See ‘Brocade<br />

Fibre Channel Switches’ at the end of this section.<br />

Setting Up Storage Area Network Fabrics <strong>and</strong> Creating Zones<br />

For instructions on setting up fabrics <strong>and</strong> creating zones, see ClearPath Plus Servers<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong> Operations Guide (6870 3511).<br />

4–2 6871 6364–003


Fibre Channel Disk Subsystems<br />

Fibre Channel Device Guidelines<br />

Guidelines for Installing the Hitachi AMS Disk Array<br />

On the <strong>Libra</strong> <strong>680</strong>, the AMS disk array can only be connected to the host via a FC3-IOP.<br />

The following table describes the minimum software levels <strong>and</strong> deviations <strong>and</strong> risk<br />

assessments for migrating a AMS disk array to a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.<br />

Table 4–2. Minimum Software Levels for Configuring a AMS Disk Array<br />

Device System Software Firmware<br />

<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

servers<br />

ClearPath MCP 10.1<br />

ClearPath MCP 11.0<br />

Guidelines for Installing the EuroLogic JBD2000 JBOD Rack<br />

On the <strong>Libra</strong> <strong>680</strong>, the JBD2000 can only be connected to the host via a FC3-IOP. The<br />

following tables describe the minimum software levels <strong>and</strong> deviations <strong>and</strong> risk<br />

assessments for migrating a JBD2000 to a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.<br />

Table 4–3. Minimum Software Levels for Configuring a JBOD2000<br />

Device System Software Firmware<br />

<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

servers<br />

Restrictions<br />

ClearPath MCP 10.1<br />

ClearPath MCP 11.0<br />

• Host Interfaces are all optical Fibre Channel. Copper cables are only used to<br />

interconnect racks.<br />

• Splitting the JBOD2000 racks into two loops within the same rack it not supported.<br />

• When running on fabric <strong>and</strong> multiple Initiators are used, separate zones should be<br />

used from each initiator that overlap at the storage port so that initiators are not in<br />

the same zone. For instructions on setting up fabrics <strong>and</strong> creating zones, see<br />

ClearPath Plus Servers <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong><br />

Operations Guide.<br />

6871 6364–003 4–3<br />

1.1<br />

1.1


Fibre Channel Device Guidelines<br />

Guidelines for Installing the EMC Clariion CX3 Disk Array<br />

On the <strong>Libra</strong> <strong>680</strong>, the CX3 Disk Array can only be connected to the host via a FC3-IOP.<br />

The following table describes the minimum software levels for configuring a CX3 Disk<br />

Array.<br />

Table 4–4. Minimum Software Levels for Configuring a CX3 Disk Array<br />

Device System Software Firmware<br />

<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

servers<br />

Restrictions<br />

ClearPath MCP 10.0:<br />

MCP IC 051.1A.84<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.0<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

MCP Platform<br />

Firmware release<br />

1.1<br />

• Mixing of CX3-20/40/80, <strong>and</strong> other fibre channel control types on the same attach<br />

Loop is not allowed <strong>and</strong> not supported.<br />

• <strong>Support</strong>ed splits configurations for Raid group of 2 disks is16 splits, Raid group of 5<br />

disks is 32 splits, Raid group of 7 disks is 64 splits.<br />

• Configurations using single disks are not supported.<br />

• When the 300 GB 2 Gb fibre channel drive is used as a backend drive in the disk<br />

array, all the drives in that rack will default to 2 Gb loop speeds.<br />

Guidelines for Installing the iQstore JBOD 4000 Disk<br />

Subsystem<br />

On the <strong>Libra</strong> <strong>680</strong> <strong>and</strong> <strong>FS1800</strong>, the iQstore JBOD 4000 Disk Subsystem can only be<br />

connected to the host via a FC3-IOP. The following table describes the minimum<br />

software levels for configuring a iQstore JBOD 4000 Disk Subsystem.<br />

4–4 6871 6364–003


Fibre Channel Device Guidelines<br />

Table 4–5. Minimum Software Levels for Configuring a iQstore JBOD<br />

4000 Disk Subsystem<br />

Device System Software Firmware<br />

<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

servers<br />

<strong>FS1800</strong><br />

Restrictions<br />

ClearPath MCP 10.0:<br />

MCP IC 051.1A.84<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.0<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

ClearPath MCP 10.0:<br />

MCP IC 051.1A.101<br />

LOAD –UTILS IC 051.1A.17<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.0<br />

MCP IC 052.1A.32<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

MCP Platform<br />

Firmware release<br />

1.1<br />

MCP Platform<br />

Firmware release<br />

1.0<br />

On the <strong>Libra</strong> <strong>680</strong> <strong>and</strong> <strong>FS1800</strong>, the iQstore JBOD 4000 Disk Subsystem can only be<br />

connected<br />

• The use of direct attach configurations on the <strong>Libra</strong><br />

185/580/590/585/595/VSE500/FS1600 using the FCA1850-LC is restricted.<br />

• Drive Replacements on the <strong>Libra</strong>185/580/590/585/595/VSE500/FS1600 are restricted<br />

unless the entire JBOD 4000 rack is removed from use, or to times when the<br />

system I/O rate is very low.<br />

• Drive Replacements when the Brocade 3800/3200 switch is used, requires that the<br />

rack be taken out of service during the replacement.<br />

6871 6364–003 4–5


Fibre Channel Device Guidelines<br />

Operational Characteristics <strong>and</strong> Features<br />

• Mixing of JBOD 4000, <strong>and</strong> other fibre channel control types on the same attach Loop<br />

is not allowed <strong>and</strong> not supported.<br />

• When concatenating JBOD4000 racks, configurations of up to six racks<br />

concatenated in a direct connect configuration is supported, but in fabric<br />

configurations no more than two racks concatenated <strong>and</strong> connected to a switch port<br />

are supported.<br />

• JBOD4000/RTS4001 racks are only supported when configured using the HID<br />

address mode setting.<br />

• JBOD4000/RTS4001 racks cannot auto sense the fibre channel interface speed. The<br />

racks have a switch-able front panel setting for either 2 Gb or 4 Gb speed that sets<br />

all ports in the rack to that speed.<br />

• It is recommended to use a 4Gb Fibre channel HBA in the SBOD manager server in a<br />

direct connect configuration where monitoring is required. Otherwise using 2Gb<br />

Fibre Channel HBAs will require all the JBOD4000 racks connected to the HBA to be<br />

set to 2Gb fibre channel speeds.<br />

• The SBOD Manager Server must be rebooted any time physical changes are made<br />

to the SBOD environment to get the SBOD Manager to recognize the changes.<br />

• SBOD manager may lose socket connection after about 72 hours of continuous<br />

operation. A restart of the manager is required for continuation of monitoring.<br />

• Using SBOD manager version 5010, the Fibre Channel speed label <strong>and</strong> value is<br />

incorrectly shown as 6GB. This will be corrected to show 4Gb in a future release.<br />

4–6 6871 6364–003


Fibre Channel Device Guidelines<br />

CX300, CX500, <strong>and</strong> CX700 Open Storage RAID Subsystem<br />

Configuration Guidelines<br />

The following table describes the minimum software levels for configuring a CX300,<br />

CX500, or CX700 RAID subsystem.<br />

Table 4–6. Minimum Software Levels for Configuring a CX300,<br />

CX500, or CX700 on a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware<br />

ClearPath MCP 10.1:<br />

MCP Platform<br />

MCP IC 051.1A.84<br />

Firmware 1.1<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

Fibre Channel Tape Subsystems<br />

CTS9840 Fibre Channel Tape Configuration<br />

The CTS9840 requires the use of control type FCSCSIMT in the PCD of the partition<br />

profile. The maximum number of drives per channel is two due to channel b<strong>and</strong>width<br />

limits. The mixing of CTS9840 <strong>and</strong> ESM7700 on the same loop is not allowed.<br />

The CTS9840 has two FC ports on the unit. Both ports can assess the drive but not at<br />

the same time. Only one port can be used. Port A is used for even numbered addresses<br />

<strong>and</strong> Port B is used for odd numbered addresses.<br />

Configure CTS9840A for Fabric<br />

To set the CTS9840A tape drive for Fabric, perform the following.<br />

Notes:<br />

• The tape drive must be a CTS9840A (STK part number 312102401) <strong>and</strong> must be at a<br />

minimum firmware level of R1.30.110f to install on the fabric.<br />

6871 6364–003 4–7


Fibre Channel Device Guidelines<br />

• For more information on configuring the CTS9840, refer to CTS9840 Cartridge Tape<br />

Subsystem Installation Guide (8999 5310).<br />

1. Take the drive offline.<br />

2. Go to the drive configuration menu for Fibre Channel.<br />

3. Go to the Port A <strong>and</strong> B Attributes <strong>and</strong> set Hard PA=Y. This will set the drive to<br />

ports to operate in FL_Port mode.<br />

4. Set the loop address.<br />

• For instructions on setting up fabrics <strong>and</strong> creating zones, see ClearPath Plus Servers<br />

<strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong> Operations Guide.<br />

CTS9840B Fibre Channel Tape Configuration Guidelines<br />

The CTS9840B requires the use of control type FCSCSIMT in the PCD of the partition<br />

profile.<br />

CTS9840C Fibre Channel Tape Configuration Guidelines<br />

The CTS9840C requires the use of control type FCSCSIMT in the PCD of the partition<br />

profile. Table 4-5 describes the minimum software levels for configuring a CTS9840C.<br />

Table 4–7. Minimum Software Levels for Configuring a CTS9840C on<br />

a <strong>Libra</strong>s <strong>680</strong>/<strong>690</strong><br />

System Software Firmware<br />

ClearPath MCP 10.1:<br />

MCP Platform<br />

MCP IC 051.1A.84<br />

Firmware 1.1<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

4–8 6871 6364–003


Fibre Channel Device Guidelines<br />

Fibre Channel Linear Tape-Open (LTO) Gen2 Tape Drive for CLU<br />

<strong>Libra</strong>ries<br />

Linear Tape-Open (LTO) Technology offers enterprise system environments a tape<br />

solution that addresses the performance, capacity, reliability <strong>and</strong> management issues<br />

faced when choosing a tape solution. LTO Technology is ideal in the SAN environment<br />

because it meets the special tape dem<strong>and</strong>s that SANs create.<br />

Similar to digital linear tape drives (DLT), LTO drives write data tracks in a linear,<br />

serpentine fashion. When the end of the tape is reached, the heads are repositioned<br />

above or below their current location, <strong>and</strong> recording resumes in the opposite direction.<br />

There are two Fibre Channel LTO drives supported on ClearPath enterprise servers: the<br />

CLU180-22F for CLU180 libraries <strong>and</strong> the CLU700-22F for CLU700 libraries.<br />

Tables 4-6 lists the software level qualified for use with the LTO drives.<br />

Table 4–8. Minimum Software Levels for Configuring a LTO Gen2 on a<br />

<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware Level<br />

ClearPath MCP 10.1:<br />

MCP Platform Firmware 1.1M<br />

MCP IC 051.1A.84<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

LTO Gen2 Restrictions<br />

• Mixing of CLU180-22F, CLU700-22F, <strong>and</strong> other fibre channel control types on<br />

the same attach Loop is not allowed <strong>and</strong> restricted.<br />

• For Fabric connected configurations, the relationship of one channel to up to two<br />

units should be maintained <strong>and</strong> it is recommended that they be placed in a zone.<br />

If more channels <strong>and</strong> units are attached to the same fabric they should each be<br />

in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to h<strong>and</strong>le the<br />

additional units <strong>and</strong> channels. For instructions on setting up fabrics <strong>and</strong> creating<br />

zones, see ClearPath Plus Servers <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> Administration <strong>and</strong><br />

Operations Guide.<br />

6871 6364–003 4–9


Fibre Channel Device Guidelines<br />

• When the CLU180-22F, CLU700-22F tape drive is used with fabric connections<br />

no changes to the default sets are required<br />

• To run in Direct attach (Arbitrated Loop), QuickLoop (Arbitrated Loop), Fabric<br />

<strong>Public</strong> Loop device (NL-Port), or as a Fabric (N-Port) device with the CLU180-22F,<br />

CLU700-22F. Either set a hard fibre channel address of 1 - 125 in either AL mode<br />

or in NL- Port fabric mode or by using an address of 126 allow the device to<br />

operate as a Fabric point to point N-port device.<br />

To set this value, on the front of the L700/L180 CLU <strong>Libra</strong>ry perform the<br />

following.<br />

1. Press Menu<br />

2. Select Configuration<br />

3. Select Drive configuration (note drive must be unloaded)<br />

4. Press the arrow buttons to scroll to the drive you wish to configure <strong>and</strong><br />

press the SELECT button (Should be an HP LTO2 Fiber I/F drive)<br />

5. Press the arrow buttons to scroll to the LOOP ID: setting <strong>and</strong> press select.<br />

6. A display indicating PORT A Loop ID should be shown.<br />

Valid HRD Addr 1-125<br />

To ENA HRD use 1-125<br />

To ENA SOFT use 126.<br />

Scroll up to Incr.<br />

Scroll down to Decr.<br />

Select to Save<br />

Menu to exit.<br />

Changing the value to 126 <strong>and</strong> pressing the menu to exit will then cause the<br />

LOOP ID displayed in the previous screen to display AUTO. The display will<br />

also indicate that the Hard Address has been disabled.<br />

DSI2000/4000 Tape <strong>Libra</strong>ry System<br />

Tables 4-7 lists the software level qualified for use with the DSI/2000/4000 drives.<br />

Table 4–9. Minimum Software Levels for Configuring a DSI2000/4000<br />

Tape <strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware Level<br />

ClearPath MCP 10.1:<br />

MCP IC 051.1A.84<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

Platform Firmware release 1.0<br />

4–10 6871 6364–003


Fibre Channel Device Guidelines<br />

Table 4–9. Minimum Software Levels for Configuring a DSI2000/4000<br />

Tape <strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />

System Software Firmware Level<br />

ClearPath MCP 11.1<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

DSI2000/4000 Restrictions<br />

• Mixing of DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV tape drive,<br />

<strong>and</strong> other fibre channel control types on the same attach Loop is not allowed <strong>and</strong><br />

restricted.<br />

• Quickloop connections are not supported.<br />

• The DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV tape drive does<br />

not utilize a Hard Addressing scheme for connection to FC_AL arbitrated loop. This<br />

device uses a Soft address scheme that starts the process of obtaining a loop<br />

address (soft) at the high end of the AL_PA table of AL_PA’s starting at the first<br />

available address. For example, if one initiator were used in this configuration the<br />

starting loop address would be 124 or AL_PA=02, since the FCA1850-LC initiator<br />

would occupy address 125 or AL_PA=01. Based on this addressing scheme, the<br />

DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV must be the only target<br />

device on the FC_AL to the host initiator when direct connect FC_AL mode is<br />

configured. If the Port WWID of the DSI2100, DSI2200, DSI4100, DSI4200 using<br />

the DSIF63-REV can be determined though the use of a switch, then that value can<br />

be used in the configuration file e.g.(.cef) instead of a loop address. When using this<br />

device in a fabric configuration the WWID Port Name should always be used in the<br />

configuration file.<br />

• For Fabric connected configurations, the relationship of one channel to up to two<br />

units should be maintained <strong>and</strong> it is recommended that they be placed in a zone. If<br />

more channels <strong>and</strong> units are attached to the same fabric they should each be in their<br />

own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to h<strong>and</strong>le the additional<br />

units <strong>and</strong> channels.<br />

• Only one port on the DSIF63-REV should be in use, <strong>and</strong> the other port can only be<br />

used as a Hot St<strong>and</strong>by<br />

6871 6364–003 4–11


Fibre Channel Device Guidelines<br />

Brocade Fibre Channel Switches<br />

This subsection is a matrix of Brocade switches <strong>and</strong> Fibre Channel peripherals with<br />

ClearPath MCP servers. Table 4-8 lists the system software <strong>and</strong> firmware levels for<br />

operation with the switches in Table 4-9. Table 4-10 lists the storage devices <strong>and</strong> their<br />

firmware levels qualified to operate with the devices in Table 4-9..<br />

Table 4–10. <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> System Software Levels for Operation with<br />

Brocade Switches<br />

System Software Firmware<br />

ClearPath MCP 10.1:<br />

System Release 1.1<br />

Platform Firmware 1.1<br />

MCP IC 051.1A.84<br />

LOAD –UTILS IC 051.1A.16<br />

LOG-TOOLS IC 051.1A.17<br />

DumpAnalyzer IC 051.1A.13<br />

ClearPath MCP 11.1<br />

MCP IC 052.1A.17<br />

LOAD –UTILS IC 052.1A.1<br />

LOG-TOOLS IC 052.1A.3<br />

DumpAnalyzer IC 052.1A.1<br />

4–12 6871 6364–003


Fibre Channel Device Guidelines<br />

Table 4–11. Qualified Brocade Switch Firmware Levels<br />

Switch Style Number Description Firmware<br />

HSC30449-S32 Brocade 4900<br />

32 Port Switch<br />

HSC30449-S64 Brocade 4900<br />

64 Port Switch<br />

HSC 3043252-VL2 Brocade 3252- 8 Port, 2switch<br />

limitation.<br />

HSC 3043250-FF Brocade 3250 - 8 Port, Full<br />

Fabric.<br />

HSC 3043850-FF Brocade 3850 - 16 Port Full<br />

Fabric.<br />

HSC30439-S32 Brocade 3900 - 32 Port<br />

Switch<br />

HSC3041200-D64 Brocade 12000 2 x 64 Ports<br />

Switch<br />

HSC3041200-S32 Switch 2Gb FC 1x32-Ports.<br />

Core FC fabric<br />

HSC3041200-S64 Switch 2Gb FC 1x64-Ports.<br />

Core FC fabric<br />

HSC50400-SWL Shortwave Laser SFP<br />

HSC50400-SFL Longwave Laser SFP<br />

HSC30438-S16 Brocade 3800 16 Port 2 Gb<br />

HSC30432-S08 Brocade 3200 8 Port 2 Gb<br />

HSC30428-S16 Brocade 2800 16 Port 1Gb<br />

HSC30424-S08<br />

Brocade 2400 8 Port 1Gb<br />

HSC30464-S64 Rack Mountable, 64 port<br />

Integrated 1Gb<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

5.1.0a<br />

v3.2.1<br />

v3.2.1<br />

v2.6.2a<br />

v2.6.2a<br />

v2.6.2a<br />

6871 6364–003 4–13


Fibre Channel Device Guidelines<br />

Table 4–12. Qualified Storage Device Firmware Levels<br />

Device Style Number Description<br />

CTS9840/CTS7840 FC Tape<br />

Firmware<br />

CTS9840-FDL<br />

FC Drive on<br />

1.34.154f<br />

CTS7840-FDL<br />

CLU6000/9740/1000<br />

<strong>Libra</strong>ries Tray Assembly<br />

CTS9840-FD9 FC Drive on CLU9710<br />

<strong>Libra</strong>ry Tray Assembly<br />

CTS9840-FRA Rackmount Autoloader with<br />

FC Drive<br />

CTS9840-FLL<br />

CTS7840-FLL<br />

FC Drive on L-Series <strong>Libra</strong>ry<br />

Tray Assembly<br />

CTS7840-FR1 FC Drive, Rack Mount,<br />

Single<br />

1.34.154f<br />

1.34.154f<br />

1.34.154f<br />

1.34.154f<br />

CTS7840-FR2 FC Drive, Rack Mount, Dual 1.34.154f<br />

CTS9840B FC Tape<br />

CTB9840-FDL FC, Drive on CLU6000/9740<br />

<strong>Libra</strong>ries Tray<br />

CTB9840-FLL FC, Drive on CLU180/700<br />

<strong>Libra</strong>ries Tray<br />

CTB9840-FR1 FC, Drive Rack Mount<br />

Single.<br />

1.34.352f<br />

1.34.352f<br />

1.34.352f<br />

CTB9840-FR2 FC, Drive Rack Mount Dual 1.34.352f<br />

CTB9840-FTM FC, Drive Table Top 1.34.352f<br />

CTS9840 FC Tape<br />

CTC9840-FDL FC Drive in CLU 9741 tray<br />

Mount<br />

CTC9840-FLL FC Drive in CLU 180/700<br />

tray Mount<br />

1.34.553<br />

1.34.553<br />

CTC9840-FR1 FC Single Drive 1.34.553<br />

4–14 6871 6364–003


Fibre Channel Device Guidelines<br />

Table 4–12. Qualified Storage Device Firmware Levels<br />

Device Style Number Description Firmware<br />

CTC9840-FR2 FC Rack Mount FC Drives 1.34.553<br />

CTB9940 FC Tape<br />

CTB9940-FDL FC, Drive on CLU6000/9740<br />

<strong>Libra</strong>ries Tray<br />

CTB9940-FLL FC, Drive on CLU180/700<br />

<strong>Libra</strong>ries Tray<br />

CLUxxx-22F LTO Tape<br />

CLU180-22 HP FC LTO Gen2 drive on<br />

CLU180 tray<br />

CLU700-22F HP FC LTO Gen2 drive on<br />

CLU700<br />

1.32.421<br />

1.32.421<br />

K3A1<br />

K3A1<br />

HDS AMS<br />

AMS200 AMS 200 Array 0732/A-M<br />

AMS500 AMS 500 Array 0732/A-M<br />

AMS1000 AMS 1000 Array 0732/A-M<br />

JBD2000 JBOD<br />

JBD2022-HA<br />

JBD2000 High Availability<br />

Enclosure, Dual<br />

Optical/Copper I/O Modules<br />

JBD2040-HA JBD2000 High Availability<br />

Enclosure, Dual<br />

Optical/Optical I/O Modules<br />

JBD2004-HA JBD2000 High Availability<br />

Expansion Enclosure, Dual<br />

Copper/Copper I/O<br />

Modules<br />

JBD2011-SA JBD2000 St<strong>and</strong>ard<br />

Availability Enclosure,<br />

Single Optical/Copper I/O<br />

Module<br />

JBD2020-SA JBD2000 St<strong>and</strong>ard<br />

Availability Enclosure,<br />

Single Optical/Optical I/O<br />

Module<br />

2GB-V2.5.0<br />

2GB-V2.5.0<br />

2GB-V2.5.0<br />

2GB-V2.5.0<br />

2GB-V2.5.0<br />

6871 6364–003 4–15


Fibre Channel Device Guidelines<br />

Table 4–12. Qualified Storage Device Firmware Levels<br />

Device Style Number Description Firmware<br />

JBD2002-SA JBD2000 St<strong>and</strong>ard<br />

Availability Expansion<br />

Enclosure, Single<br />

Copper/Copper I/O Module<br />

JBD201815-2F JBD2000 18GB 15K RPM<br />

disk, Factory Installed<br />

JBD201815-2F JBD2000 36GB 15K RPM<br />

disk, Factory Installed<br />

JBD203610-2F JBD2000 36GB 10K RPM<br />

disk, Factory Installed<br />

EMC CLARiiON Disk<br />

CX7001-DPE CX700 SPE HA W 8GB<br />

MEMORY<br />

CX700-SPE CX700-FD SPE8GB FIELD<br />

INS<br />

CX700-DAV CX700 DAE W OS<br />

FACTORY INSTALL<br />

CX7001-DAV CX700 DAE W OS<br />

FACTORY INSTALL<br />

CX5001-DPE CX500 FIBRE CHANNEL W<br />

4GB<br />

2GB-V2.5.0<br />

4–16 6871 6364–003<br />

0005<br />

0005<br />

0005<br />

CX700 Bundle<br />

02.19.700.5.030<br />

CX700 Bundle<br />

02.19.700.5.030<br />

CX700 Bundle<br />

02.19.700.5.030<br />

CX700 Bundle<br />

02.19.700.5.030<br />

CX500 Bundle<br />

02.19.500.5.030<br />

CX500-DPE CX500 FC 4G FIELD INST CX500 Bundle<br />

02.19.500.5.030<br />

CX3001-DPE CX300 FC 2GB CX300 Bundle<br />

02.19.300.5.030<br />

CX300-DPE CX300 3U DPE HA w/SPS,<br />

FIELD INSTALL<br />

CXR7310-2GF CHV 73Gb 10K 520BPS<br />

12V 2Gb<br />

CX300 Bundle<br />

02.19.500.5.030<br />

R570<br />

7A06


CXR14610-2GF 146GB 10K 520BPS 2Gb<br />

12V<br />

CX6001-SPE CX600 SPE, FACTORY<br />

INSTALL<br />

Fibre Channel Device Guidelines<br />

R570<br />

7A06<br />

CX600 Bundle<br />

02.19.600.5.030<br />

CX600-SPE CX600 FIELD INSTALL CX600 Bundle<br />

02.19.600.5.030<br />

CX600-DAV CX600-1 st DAE W/UNIVER CX600 Bundle<br />

02.19.600.5.030<br />

CX4001-DPE CX400 DPE CX400 Bundle<br />

02.19.400.5.030<br />

CX400-DPE CX400 DPE FIELD INSTALL CX400 Bundle<br />

02.19.400.5.030<br />

CXR3615-2GF 36GB 15K RPM<br />

CXR7315-2GF 73GB 15K RPM<br />

SYMM 5.0<br />

CAB8430-18<br />

CAB8430-36<br />

CAB8430-50<br />

CAB8730-18<br />

CAB8730-36<br />

CAB8730-50<br />

SYMM5.5<br />

CAB8230-XX<br />

CAB8530-XX<br />

CAB8830-XX<br />

EMC Disk Subsystems<br />

5566.22.17<br />

5568.47.17<br />

DMX3 5771.86.95<br />

DMX 800 5670<br />

DMX 801 5670<br />

DMX 1000 5670<br />

DMX 2000 5670<br />

6871 6364–003 4–17


Fibre Channel Device Guidelines<br />

DMX 3000 5670<br />

DMX1500 5771.81.90<br />

DMX2500 5771.81.90<br />

DMX3500 5771.81.90<br />

DMX4500 5771.81.90<br />

4–18 6871 6364–003


Appendix A<br />

Host Bus Adapter Cables<br />

Signal cables connect the server to the peripherals.<br />

Cables in this appendix include<br />

• SCSI host bus port<br />

• Fibre Channel<br />

• Keyboard, monitor, <strong>and</strong> mouse<br />

• LAN<br />

The cables <strong>and</strong> cable adapters listed are for the most typical applications. Some<br />

configurations might require additional adapters or terminators.<br />

When ordering peripheral signal cables, refer to the documentation for the peripheral<br />

device or subsystem. Some subsystems require two sets of cables. Some connections<br />

require adapters or adapter cables<br />

SCSI Host Bus Port<br />

The host bus ports are connected to external storage devices. When ordering cables,<br />

use the shortest cable length possible to connect components.<br />

Fibre Channel<br />

Refer to Section 3 for fibre channel interface characteristics <strong>and</strong> brocade switch options.<br />

For longwave requirements consult Unisys Sales <strong>Support</strong>.<br />

DB9-to-DB9 Cables<br />

You can connect either the equalized or nonequalized copper interface cables (See Table<br />

A–1). Dual-loop installations require two adapters <strong>and</strong> two cables per subsystem.<br />

Table A–1. Fibre Channel Copper Interface Cables<br />

Style Description<br />

CBL135-1 FC cable, 1-meter, unequalized<br />

6871 6364–003 A–1


Host Bus Adapter Cables<br />

DB9-to-HSSDC Cables<br />

Table A–1. Fibre Channel Copper Interface Cables<br />

Style Description<br />

CBL135-3 FC cable, 3-meter, unequalized<br />

CBL135-5 FC cable, 5-meter, unequalized<br />

CBL135-10 FC cable, 10-meter, unequalized<br />

CBL135-15 FC cable, 15-meter, unequalized<br />

CBL137-20 FC cable, 20-meter, equalized<br />

CBL137-25 FC cable, 25-meter, equalized<br />

CBL137-30 FC cable, 30-meter, equalized<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

Table A–2. DB9-to-HSSDC Fibre Channel Interface<br />

Cables<br />

Style Description<br />

CBL136-1 FC cable, 1-meter, unequalized<br />

CBL136-3 FC cable, 3-meter, unequalized<br />

CBL136-5 FC cable, 5-meter, unequalized<br />

CBL136-10 FC cable, 10-meter, unequalized<br />

CBL136-15 FC cable, 15-meter, unequalized<br />

CBL138-20 FC cable, 20-meter, equalized<br />

CBL138-25 FC cable, 25-meter, equalized<br />

CBL138-30 FC cable, 30-meter, equalized<br />

A–2 6871 6364–003


HSSDC-to-HSSDC Cables<br />

Host Bus Adapter Cables<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

HSSDC–2-to-DB9 Cables<br />

Table A–3. HSSDC-to-HSSDC Fibre Channel Interface<br />

Cables<br />

Style Description<br />

CBL147-1 FC cable, 1-meter, unequalized<br />

CBL147-3 FC cable, 3-meter, unequalized<br />

CBL147-5 FC cable, 5-meter, unequalized<br />

CBL147-10 FC cable, 10-meter, unequalized<br />

CBL147-15 FC cable, 15-meter, unequalized<br />

CBL148-20 FC cable, 20-meter, equalized<br />

CBL148-25 FC cable, 25-meter, equalized<br />

CBL148-30 FC cable, 30-meter, equalized<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

Table A–4. HSSDC–2-to-DB9 Fibre Channel Interface<br />

Cables<br />

Style Description<br />

CBL174-1 HSSDC-2 to DB9, 1-meter cable, 1 Gb<br />

CBL174-3 HSSDC-2 to DB9, 3-meter cable, 1 Gb<br />

CBL174-5 HSSDC-2 to DB9, 5-meter cable, 1 Gb<br />

CBL174-10 HSSDC-2 to DB9, 10-meter cable, 1 Gb<br />

6871 6364–003 A–3


Host Bus Adapter Cables<br />

HSSDC-to-HSSDC–2 Cables<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

Table A–5. HSSDC to HSSDC–2 Fibre Channel Interface<br />

Cables<br />

Style Description<br />

CBL175-1 HSSDC to HSSDC-2, 1-meter cable, 1 Gb<br />

CBL175-3 HSSDC to HSSDC-2, 3-meter cable, 1 Gb<br />

CBL175-5 HSSDC to HSSDC-2, 5-meter cable, 1 Gb<br />

CBL175-10 HSSDC to HSSDC-2, 10-meter cable, 1 Gb<br />

LC-to-SC, 1 Gb Shortwave Optical Cables<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

Table A–6. LC-to-SC Shortwave Optical Interface<br />

Cables<br />

Style Description<br />

CBL170-2 LC-to-SC shortwave cable, 2-meter, (1 Gb)<br />

CBL170-5 LC-to-SC shortwave cable, 5-meter, (1 Gb)<br />

CBL170-10 LC-to-SC shortwave cable, 10-meter, (1 Gb)<br />

CBL170-50 LC-to-SC shortwave cable, 50-meter, (1 Gb)<br />

CBL170-100 LC-to-SC shortwave cable, 100-meter, (1 Gb)<br />

CBL170-200 LC-to-SC shortwave cable, 200-meter, (1 Gb)<br />

CBL170-300 LC-to-SC shortwave cable, 300-meter, (1 Gb)<br />

CBL170-500 LC-to-SC shortwave cable, 500-meter, (1 Gb)<br />

A–4 6871 6364–003


LC-to-LC, Fibre Channel Optical Cables<br />

Host Bus Adapter Cables<br />

Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />

Longwave Cables<br />

Table A–7. LC-to-LC Fibre Channel Optical Interface Cables<br />

Style Description<br />

CBL171-2 LC-to-LC shortwave cable, 2meter,<br />

(2 Gb or 4Gb)<br />

CBL171-5 LC-to-LC shortwave cable, 5meter,<br />

2 Gb or 4Gb)<br />

CBL171-10 LC-to-LC shortwave cable, 10meter,<br />

2 Gb or 4Gb)<br />

CBL171-25 LC-to-LC shortwave cable, 25meter,<br />

2 Gb or 4Gb)<br />

CBL171-50 LC-to-LC shortwave cable, 50meter,<br />

(2 Gb or 4Gb)<br />

CBL171-100 LC-to-LC shortwave cable, 100meter,<br />

2 Gb or 4Gb)<br />

CBL171-200 LC-to-LC shortwave cable, 200meter,<br />

(2 Gb only)<br />

CBL171-300 LC-to-LC shortwave cable, 300meter,<br />

(2 Gb only)<br />

For connecting from a disk<br />

array to a 2 Gb or 4 Gb<br />

switch or for connecting a<br />

FC3-IOP adapter to a 2Gb or<br />

4Gb switch or to the disk<br />

array.<br />

For installations where longwave cables are suitable, over 500 meters, Consult Unisys<br />

Sales <strong>Support</strong> for applicable cable styles <strong>and</strong> interface converters.<br />

Monitor, Keyboard, <strong>and</strong> Mouse<br />

The cables for the console components are not usually ordered separately. In a<br />

dual-domain configuration, if you do not use the display switch, you must use two sets<br />

of console components.<br />

Table A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables<br />

Style Description Notes<br />

KVM12-EXT Cable, keyboard, video, mouse<br />

extension, 12-feet<br />

This is a combination cable that<br />

extends the console component<br />

cables from the service<br />

processor or from the optional<br />

switch.<br />

6871 6364–003 A–5


Host Bus Adapter Cables<br />

Table A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables<br />

Style Description Notes<br />

CBL121-SWC Cable, keyboard, monitor, mouse cable,<br />

system-to-switch, 12-feet<br />

LAN<br />

This cable is part of the display<br />

switch package.<br />

In a dual-domain configuration, the CBL24-7 cable connects the two Uniscreen hubs.<br />

Table A–9. LAN Cables<br />

Style Description<br />

CBL24-7 Cable, 7-meter, cross-over, Ethernet 10/100 Base-T<br />

DSH600001-TBT Cable, 1-meter, straight through<br />

DSH600002-TBT Cable, 2-meter, straight through<br />

DSH600003-TBT Cable, 3-meter, straight through<br />

DSH600004-TBT Cable, 4-meter, straight through<br />

DSH600007-TBT Cable, 7-meter, straight through<br />

A–6 6871 6364–003


Index<br />

A<br />

Audience, 1-1<br />

C<br />

cable<br />

console components, A-5<br />

LAN, A-6<br />

SCSI host bus port, A-1<br />

Crypto Co-Processor, 2-3<br />

CTS9840 Fibre Channel Tape<br />

Configuration, 4-7<br />

CTS9840A, Configure for Fabric, 4-7<br />

D<br />

digital linear tape drives (DLT), 4-9<br />

E<br />

ePortal Hardware, 2-4<br />

F<br />

FC3-IOP, 2-8<br />

Fibre Channel - Arbitrated Loop topology (FC-<br />

AL), 4-1<br />

fibre channel adapter, 4-1<br />

Fibre Channel Protocol<br />

definition, 4-1<br />

L<br />

Linear Tape-Open (LTO) Technology, 4-9<br />

6871 6364–003 Index–1<br />

P<br />

Prerequisites, 1-1<br />

S<br />

SCSI Tape Appliance, 2-9<br />

Secure Maintenance Device, 2-3<br />

Serial Attached SCSI Feature, 2-8<br />

Super Digital Linear Tape, 3-3


Index<br />

Index–2 6871 6364–003


© 2007 Unisys Corporation.<br />

All rights reserved.<br />

*68716364-003*<br />

6871 6364–003