Libra Models 680, 690, and FS1800 I/O Reference - Public Support ...
Libra Models 680, 690, and FS1800 I/O Reference - Public Support ...
Libra Models 680, 690, and FS1800 I/O Reference - Public Support ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ClearPath Plus Server<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />
I/O <strong>Reference</strong><br />
January 2007
ClearPath Plus Server<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />
I/O <strong>Reference</strong><br />
January 2007 6871 6364–003<br />
unisys<br />
imagine it. done.
NO WARRANTIES OF ANY NATURE ARE EXTENDED BY THIS DOCUMENT. Any product or related information<br />
described herein is only furnished pursuant <strong>and</strong> subject to the terms <strong>and</strong> conditions of a duly executed agreement to<br />
purchase or lease equipment or to license software. The only warranties made by Unisys, if any, with respect to the<br />
products described in this document are set forth in such agreement. Unisys cannot accept any financial or other<br />
responsibility that may be the result of your use of the information in this document or software material, including<br />
direct, special, or consequential damages.<br />
You should be very careful to ensure that the use of this information <strong>and</strong>/or software material complies with the laws,<br />
rules, <strong>and</strong> regulations of the jurisdictions with respect to which it is used.<br />
The information contained herein is subject to change without notice. Revisions may be issued to advise of such<br />
changes <strong>and</strong>/or additions.<br />
Notice to U.S. Government End Users: This is commercial computer software or hardware documentation developed at<br />
private expense. Use, reproduction, or disclosure by the Government is subject to the terms of Unisys st<strong>and</strong>ard<br />
commercial license for the products, <strong>and</strong> where applicable, the restricted/limited rights provisions of the contract data<br />
rights clauses.<br />
FCC Statement<br />
The statement below is included in this document to comply with a Federal Communications Commission (FCC)<br />
regulation. The FCC is an agency of the United States government; thus, the statement below applies to computing<br />
equipment installed in the United States of America. Unisys is taking appropriate steps to be in compliance with FCC<br />
regulations <strong>and</strong> similar regulations of other countries.<br />
WARNING: This equipment has been tested <strong>and</strong> found to comply with the limits for a Class A device, pursuant to Part<br />
15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the<br />
equipment is operated in a commercial environment. This equipment generates, uses, <strong>and</strong> can radiate radio frequency<br />
energy <strong>and</strong>, if not installed <strong>and</strong> used in accordance with the instruction manual, may cause harmful interference to radio<br />
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case<br />
users will be required to correct the interference at their own expense.<br />
Canadian Regulatory Statement<br />
This class A apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.<br />
Cet appareil de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.<br />
Unisys <strong>and</strong> ClearPath are registered trademarks of Unisys Corporation in the United States <strong>and</strong> other countries.<br />
All other br<strong>and</strong>s <strong>and</strong> products referenced in this document are acknowledged to be the trademarks or registered<br />
trademarks of their respective holders.
ClearPath Plus Server<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>, <strong>690</strong>,<br />
<strong>and</strong> <strong>FS1800</strong><br />
I/O <strong>Reference</strong><br />
ClearPath Plus<br />
Server<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong>,<br />
<strong>690</strong>, <strong>and</strong> <strong>FS1800</strong><br />
I/O <strong>Reference</strong><br />
6871 6364–003 6871 6364–003<br />
Bend here, peel upwards <strong>and</strong> apply to spine.
Contents<br />
Section 1. Introduction<br />
Audience ............................................................................................... 1–1<br />
Prerequisites ......................................................................................... 1–1<br />
About This Document ........................................................................... 1–1<br />
Section 2. Qualified I/O Device Tables<br />
Qualified Devices .................................................................................. 2–1<br />
Section 3. SCSI Device Guidelines<br />
Introduction........................................................................................... 3–1<br />
Dual Initiator SCSI................................................................ 3–1<br />
Subsystem Configuration Guidelines.................................................... 3–2<br />
Tape Storage Subsystems Configuration Guidelines .......... 3–2<br />
DSI ALP60 Linear Tape Open (LTO) Gen2 .......................... 3–3<br />
ALP/SDLT320 Tape Subsystem .......................................... 3–3<br />
DSI ALP8700 Tape Subsystem ........................................... 3–7<br />
Section 4. Fibre Channel Device Guidelines<br />
General.................................................................................................. 4–1<br />
Qualification Status.............................................................. 4–1<br />
Configuration Guideline ....................................................... 4–2<br />
Setting Up Storage Area Network Fabrics <strong>and</strong><br />
Creating Zones ................................................................ 4–2<br />
Fibre Channel Disk Subsystems ........................................................... 4–3<br />
Guidelines for Installing the Hitachi AMS Disk Array .......... 4–3<br />
Guidelines for Installing the EuroLogic JBD2000<br />
JBOD Rack ...................................................................... 4–3<br />
Guidelines for Installing the EMC Clariion CX3 Disk<br />
Array ................................................................................ 4–4<br />
Guidelines for Installing the iQstore JBOD 4000<br />
Disk Subsystem .............................................................. 4–4<br />
CX300, CX500, <strong>and</strong> CX700 Open Storage RAID<br />
Subsystem Configuration Guidelines .............................. 4–7<br />
Fibre Channel Tape Subsystems .......................................................... 4–7<br />
CTS9840 Fibre Channel Tape Configuration........................ 4–7<br />
CTS9840B Fibre Channel Tape Configuration<br />
Guidelines........................................................................ 4–8<br />
6871 6364–003 iii
Contents<br />
CTS9840C Fibre Channel Tape Configuration<br />
Guidelines ........................................................................4–8<br />
Fibre Channel Linear Tape-Open (LTO) Gen2 Tape<br />
Drive for CLU <strong>Libra</strong>ries.....................................................4–9<br />
DSI2000/4000 Tape <strong>Libra</strong>ry System...................................4–10<br />
Brocade Fibre Channel Switches.........................................................4–12<br />
Appendix A. Host Bus Adapter Cables<br />
SCSI Host Bus Port............................................................................... A–1<br />
Fibre Channel........................................................................................ A–1<br />
DB9-to-DB9 Cables ............................................................. A–1<br />
DB9-to-HSSDC Cables ........................................................ A–2<br />
HSSDC-to-HSSDC Cables ................................................... A–3<br />
HSSDC–2-to-DB9 Cables .................................................... A–3<br />
HSSDC-to-HSSDC–2 Cables ............................................... A–4<br />
LC-to-SC, 1 Gb Shortwave Optical Cables .......................... A–4<br />
LC-to-LC, Fibre Channel Optical Cables .............................. A–5<br />
Longwave Cables ................................................................ A–5<br />
Monitor, Keyboard, <strong>and</strong> Mouse ............................................................ A–5<br />
LAN....................................................................................................... A–6<br />
Index ............................................................................................. 1<br />
iv 6871 6364–003
Figures<br />
3–1. Appliance Cabling – Dual Initiator Configuration with two Tape<br />
Appliances ..................................................................................................... 3–2<br />
6871 6364–003 v
Figures<br />
vi 6871 6364–003
Tables<br />
2–1. System Options ................................................................................................. 2–3<br />
2–2. SCSI Tape Drives <strong>and</strong> <strong>Libra</strong>ries.......................................................................... 2–9<br />
2–3. Storage Area Network (SAN) Fibre Channel Disks .......................................... 2–16<br />
2–4. SAN Fibre Channel Solid State Disks............................................................... 2–25<br />
2–5. SAN Fibre Channel Tape Drives <strong>and</strong> <strong>Libra</strong>ries ................................................. 2–27<br />
2–6. SAN Fibre Channel Switches ........................................................................... 2–37<br />
3–1. Minimum Requirements for ALP60 ................................................................... 3–3<br />
3–2. Minimum ClearPath System Software Required for DSI ALP320<br />
<strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.............................................................................. 3–4<br />
3–3. DSI ALP320 Styles............................................................................................. 3–5<br />
3–4. SCSI-2W (Wide) Cable Styles for ALP320 ......................................................... 3–5<br />
3–5. Minimum ClearPath System Software Required for STK SDLT320<br />
<strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.............................................................................. 3–6<br />
3–6. SDLT320 Styles.................................................................................................. 3–6<br />
3–7. SCSI-2W (Wide) Cable Styles for DLP320 ......................................................... 3–7<br />
3–8. SCSI-2W (Wide) Cable Styles for ALP8700 ....................................................... 3–7<br />
4–1. FC3-IOP Configuration Guidelines ..................................................................... 4–2<br />
4–2. Minimum Software Levels for Configuring a AMS Disk Array .......................... 4–3<br />
4–3. Minimum Software Levels for Configuring a JBOD2000 .................................. 4–3<br />
4–4. Minimum Software Levels for Configuring a CX3 Disk Array............................ 4–4<br />
4–5. Minimum Software Levels for Configuring a iQstore JBOD 4000 Disk<br />
Subsystem..................................................................................................... 4–5<br />
4–6. Minimum Software Levels for Configuring a CX300, CX500, or CX700<br />
on a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> ......................................................................................... 4–7<br />
4–7. Minimum Software Levels for Configuring a CTS9840C on a <strong>Libra</strong>s<br />
<strong>680</strong>/<strong>690</strong>.......................................................................................................... 4–8<br />
4–8. Minimum Software Levels for Configuring a LTO Gen2 on a <strong>Libra</strong><br />
<strong>680</strong>/<strong>690</strong>.......................................................................................................... 4–9<br />
4–9. Minimum Software Levels for Configuring a DSI2000/4000 Tape<br />
<strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>................................................................. 4–10<br />
4–10. <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> System Software Levels for Operation with Brocade<br />
Switches ...................................................................................................... 4–12<br />
4–11. Qualified Brocade Switch Firmware Levels..................................................... 4–13<br />
4–12. Qualified Storage Device Firmware Levels...................................................... 4–14<br />
A–1. Fibre Channel Copper Interface Cables .............................................................A–1<br />
A–2. DB9-to-HSSDC Fibre Channel Interface Cables.................................................A–2<br />
A–3. HSSDC-to-HSSDC Fibre Channel Interface Cables............................................A–3<br />
A–4. HSSDC–2-to-DB9 Fibre Channel Interface Cables.............................................A–3<br />
A–5. HSSDC to HSSDC–2 Fibre Channel Interface Cables........................................A–4<br />
A–6. LC-to-SC Shortwave Optical Interface Cables ...................................................A–4<br />
A–7. LC-to-LC Fibre Channel Optical Interface Cables...............................................A–5<br />
6871 6364–003 vii
Tables<br />
A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables ............................................................. A–5<br />
A–9. LAN Cables ........................................................................................................ A–6<br />
viii 6871 6364–003
Section 1<br />
Introduction<br />
Audience<br />
This guide presents the specific style definitions <strong>and</strong> configuration information needed<br />
by the Sales, Sales <strong>Support</strong>, <strong>and</strong> U-ACT organizations to effectively process an initial<br />
Unisys ClearPath Plus <strong>Libra</strong> Model <strong>680</strong>/<strong>690</strong> system level order <strong>and</strong> subsequent<br />
upgrades.<br />
This guide also provides information to assist individuals responsible for defining <strong>and</strong><br />
configuring the input/output (I/O) subsystem of the server, while taking into<br />
consideration future expansion <strong>and</strong> maximum throughput.<br />
The audience for this guide includes:<br />
Prerequisites<br />
• Unisys sales personnel<br />
• Unisys sales support personnel<br />
• Unisys service representatives<br />
This guide assumes a working knowledge of large-scale computer systems.<br />
About This Document<br />
The information in this guide is contained in the following sections:<br />
Section 1 - Introduction – provides an overview of the document.<br />
Section 2 – Qualified I/O Device Tables – A matrix of all peripheral <strong>and</strong> I/O devices<br />
supported on the ClearPath <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong>. Included are related interface <strong>and</strong><br />
firmware information.<br />
Section 3 – SCSI Device Guidelines – covers SCSI tape appliance <strong>and</strong> storage<br />
device subsystems that can be migrated using this appliance. Information provided<br />
includes configuration examples, cabling, minimum device <strong>and</strong> system firmware<br />
requirements, <strong>and</strong> operational restrictions.<br />
6871 6364–003 1–1
Introduction<br />
Section 4 – Fibre Channel Device Guidelines – covers the FC3-IOP <strong>and</strong> the<br />
storage systems supported. Information provided includes configuration examples,<br />
cabling, minimum device <strong>and</strong> system firmware requirements, <strong>and</strong> operational<br />
restrictions.<br />
Appendix A – Host Bus Adapter Cables – lists of available SCSI, Fibre Channel,<br />
Ethernet, <strong>and</strong> various other system cables.<br />
1–2 6871 6364–003
Section 2<br />
Qualified I/O Device Tables<br />
Qualified Devices<br />
This section provides reference information for all I/O devices qualified by Unisys for use<br />
on the ClearPath <strong>680</strong> <strong>and</strong> <strong>690</strong> enterprise servers. This information is presented in tabular<br />
format to enable you to quickly access the following:<br />
• System Options (non-storage related options)<br />
• SCSI Tape Storage Devices<br />
• Fibre Channel Disk Storage Devices<br />
• SAN Fibre Channel Solid State Disks<br />
• Fibre Channel Tape Storage Devices<br />
• Fibre Channel Switches<br />
6871 6364–003 2–1
Qualified I/O Device Tables<br />
2–2 6871 6364–003
Qualified I/O Device Tables<br />
Table 2–1. System Options<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
Crypto Co-Processor<br />
Q F<br />
1U device<br />
CS firmware device<br />
Software is bundled. 2<br />
Max per cell. Max per<br />
system * (on 16x).<br />
RM1-CCP<br />
Q E<br />
Secure Maintenance Device<br />
1U rack mount Secure 1 per rack, provides a secure path for remote support of the<br />
Maintenance Device LM<strong>680</strong>/<strong>690</strong>, included in base package.<br />
RM125-SDT<br />
Q E<br />
Converter – Bisync to TCPIP<br />
1U, 4 Ports, rack mounted<br />
Style RM1004-CNV must also be ordered, qty = 1<br />
Style includes power cords <strong>and</strong> Ethernet cable<br />
Rack mounted, 4-port<br />
converter, Bisync to<br />
TCPIP<br />
RM1004-CN1<br />
Installation kit, Bisync to<br />
TCPIP converter<br />
RM1004-CNV<br />
6871 6364–003 2–3
Qualified I/O Device Tables<br />
ePortal Hardware<br />
Requires at least one dedicated Ethernet connection. Requires<br />
(2) 10BaseT cables for connection. Select from:<br />
DSH6OOOO3-TBT, 3m LAN cable<br />
DSH6OOOO4-TBT, 4m LAN cable<br />
DSH6OOOO7-TBT, 7m LAN cable<br />
Non-redundant option<br />
Requires software as follows:<br />
<strong>Libra</strong> <strong>680</strong>:<br />
Rack mounted base<br />
unit, 4U Enterprise<br />
Portal, 1 controller, 1<br />
Webserver blade, 1<br />
switch<br />
Q E<br />
1 CS10-MS CP ePortal Manager<br />
RMW4-BAS<br />
1 CS10-WM CP ePortal Web/Mobile Mod or<br />
1 CS10-WS CP ePortal Web Services Mod<br />
The limit is determined<br />
by the number of<br />
licensed networking<br />
ports (requires license<br />
key)<br />
<strong>Libra</strong> <strong>690</strong>:<br />
1 CS10-MSE CP ePortal Manager OE <strong>and</strong><br />
1 CS10-WME CP ePortal Web/Mobile OE <strong>and</strong>/or<br />
1 CS10-WSE CP ePortal Web Services OE<br />
2–4 6871 6364–003
Qualified I/O Device Tables<br />
ePortal Hardware<br />
Requires at least one dedicated Ethernet connection. Requires<br />
(2) 10BaseT cables for connection. Select from:<br />
DSH6OOOO3-TBT, 3m LAN cable<br />
DSH6OOOO4-TBT, 4m LAN cable<br />
DSH6OOOO7-TBT, 7m LAN cable<br />
Requires software as follows:<br />
<strong>Libra</strong> <strong>680</strong>:<br />
1 CS10-MS CP ePortal Manager<br />
2 CS10-WM CP ePortal Web/Mobile Mod or<br />
2 CS10-WS CP ePortal Web Services Mod<br />
Rack mounted 4U<br />
Enterprise Portal<br />
platform, 1 controller<br />
blade, 2 Webserver<br />
blades, 2 switches<br />
Q E<br />
or<br />
Optionally can add 3<br />
additional RMW4-PRCs.<br />
The limit is determined<br />
by the number of<br />
licensed networking<br />
ports (requires license<br />
key).<br />
RMW4-SVR<br />
1 CS10-WM CP ePortal Web/Mobile Mod <strong>and</strong><br />
1 CS10-WS CP ePortal Web Services Mod<br />
<strong>Libra</strong> <strong>690</strong>:<br />
1 CS10-MSE CP ePortal Manager<br />
2 CS10-WME CP ePortal Web/Mobile Mod or<br />
2 CS10-WSE CP ePortal Web Services Mod<br />
or<br />
1 CS10-WME CP ePortal Web/Mobile Mod <strong>and</strong><br />
1 CS10-WSE CP ePortal Web Services Mod<br />
6871 6364–003 2–5
Qualified I/O Device Tables<br />
ePortal Hardware<br />
Requires at least one dedicated Ethernet connection. Requires<br />
(2) 10BaseT cables for connection. Select from:<br />
DSH6OOOO3-TBT, 3m LAN cable<br />
DSH6OOOO4-TBT, 4m LAN cable<br />
DSH6OOOO7-TBT, 7m LAN cable<br />
Requires software as follows:<br />
Q E<br />
<strong>Libra</strong> <strong>680</strong>:<br />
Add-on board, Includes<br />
1 blade, no controller<br />
RMW4-PRC<br />
1 CS10-WM CP ePortal Web/Mobile Mod or<br />
1 CS10-WS CP ePortal Web Services Mod<br />
<strong>Libra</strong> <strong>690</strong>:<br />
1 CS10-WME CP ePortal Web/Mobile Mod or<br />
1 CS10-WSE CP ePortal Web Services Mod<br />
2–6 6871 6364–003
Qualified I/O Device Tables<br />
ePortal Hardware<br />
Requires at least one dedicated, licensed, Ethernet connection.<br />
Requires (2) GS516-T16 when 2 or more RMW4-ADD are<br />
ordered.<br />
Requires (2) 10BaseT cables for connection. Select from:<br />
DSH6OOOO3-TBT, 3m LAN cable<br />
DSH6OOOO4-TBT, 4m LAN cable<br />
DSH6OOOO7-TBT, 7m LAN cable<br />
Maximum of 5 Add-on<br />
4U chassis, each<br />
includes 1 webserver<br />
blade, 2 switches<br />
Q E<br />
RMW4-ADD<br />
<strong>Libra</strong> <strong>680</strong>:<br />
1 CS10-WM CP ePortal Web/Mobile Mod or<br />
1 CS10-WS CP ePortal Web Services Mod<br />
Does not require a<br />
controller blade.<br />
Optionally add 4<br />
additional RMW4-PRCs<br />
<strong>Libra</strong> <strong>690</strong>:<br />
1 CS10-WM CP ePortal Web/Mobile Mod or<br />
1 CS10-WS CP ePortal Web Services Mod<br />
<strong>Libra</strong> <strong>680</strong>:<br />
1 CS10-MS CP ePortal Manager<br />
Add-on controller blade.<br />
Used for cold spare<br />
only, not installed until<br />
needed<br />
RWM4-MGR<br />
<strong>Libra</strong> <strong>690</strong>:<br />
1 CS10-MSE CP ePortal Manager OE<br />
6871 6364–003 2–7
Qualified I/O Device Tables<br />
ePortal Hardware<br />
This style is used to add a second switch to the RMW4-BAS,<br />
no software required<br />
Add-on 10/100 Ethernet<br />
switch<br />
Used on RMW4-BAS for<br />
redundancy<br />
RMW4-SWT<br />
Requires 2 GS516-T16 when a second RMW4-ADD is<br />
configured<br />
GS516-T16 Gigabit switch, 16 Ports<br />
FC3-IOP<br />
PCI networking /<br />
storage solution; (1) GE<br />
network tap GE (copper<br />
or optical capable); (2)<br />
storage taps (optical<br />
only; 1 GB, 2GB, 4GB<br />
capable)<br />
PCA NH_FC<br />
Serial Attached SCSI Feature<br />
PCI based Boot / ODT<br />
solution<br />
PCA NH_SAS<br />
2–8 6871 6364–003
Qualified I/O Device Tables<br />
Table 2–2. SCSI Tape Drives <strong>and</strong> <strong>Libra</strong>ries<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
SCSI Tape Appliance<br />
Q F<br />
Requires one CSH 10<strong>680</strong>-IOL or CSH 10<strong>690</strong>-IOL per<br />
SCSI Tape Appliance<br />
The SCSI Tape<br />
Appliance Package style<br />
is RM10x0-SCI, it<br />
supports three (3) High<br />
Voltage Differential<br />
(HVD) SCSI ports for<br />
use in SCSI-based tape<br />
migrations. Each<br />
RM10x0-SCI requires an<br />
IO key. The number of<br />
RM1-SCI is limited to<br />
the number of available<br />
FC ports (Total system<br />
maximum is 8).<br />
RM1010-SCI (factory<br />
installed)<br />
RM1020-SCI (field<br />
installed)<br />
6871 6364–003 2–9
Qualified I/O Device Tables<br />
DSI DLT320 Tape<br />
Drive<br />
DSI SDLT320 Rack<br />
Mount Tape Drive,<br />
SCSI- High Voltage<br />
Differential (HVD)<br />
HVD Drive<br />
ALP320<br />
M SA<br />
Note: Low Voltage Differential (LVD) drives are not supported.<br />
ALP320 –RDD<br />
M SA<br />
DSI ALP320 HVD 2<br />
Drive Rack Mount Kit<br />
(Dual Buss)<br />
HVD Drive<br />
ALP3202 -RMK<br />
M SA<br />
DSI ALP320 8-Cart<br />
w/Rack Kit HVD 3U<br />
HVD Drive<br />
ALP320-RVD<br />
Cable<br />
M SA<br />
CBL133-XX. Up to 80 feet.<br />
CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />
ADP 133-FMF for concatenation<br />
DSI ALP320 –<br />
Removable 8-Cartridge<br />
w/Rack Kit<br />
HVD Drive<br />
ALP320-RAD<br />
Partition Information<br />
M SA<br />
DSI ALP320 –<br />
Removable 16-Cart<br />
w/Rack Kit<br />
HVD Drive<br />
ALP320-RSD<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
M SA<br />
DSI ALP320 –<br />
Removable 16-Cart<br />
w/Rack Kit, HVD w/SW<br />
HVD Drive<br />
ALP320-RTD<br />
M SA<br />
ALP320 -TDD DSI SDLT320 Single<br />
Tape Drive, Table Top<br />
SCSI-HVD<br />
HVD Drive<br />
2–10 6871 6364–003
Qualified I/O Device Tables<br />
DSI LTO Gen2 Tape<br />
Unit<br />
HVD Removable 8-Cart<br />
ACL, 3U<br />
ALP60<br />
M SA<br />
ALP60-RAD<br />
Firmware Level: F49Z<br />
HVD Rack mount Drive<br />
Kit<br />
M SA<br />
Cable<br />
ALP60-RDD<br />
CBL133-XX. Up to 80 feet.<br />
CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />
ADP 133-FMF for concatenation<br />
Firmware Level: F4AD<br />
HVD Removable 8-Cart<br />
ACL, 3U<br />
M SA<br />
ALP60-RSD<br />
Partition Information<br />
Firmware Level: F49Z<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
HVD Removable 16-Cart<br />
ACL, 2U w/Man<br />
M SA<br />
ALP60-RTD<br />
Firmware Level: F49Z<br />
HVD St<strong>and</strong>alone Drive<br />
M SA<br />
ALP60-TDD<br />
Firmware Level: F4AD<br />
6871 6364–003 2–11
Qualified I/O Device Tables<br />
SDLT320 Tape Drive<br />
for STK Cartridge<br />
Tape <strong>Libra</strong>ries<br />
CLU180 - SDLT320<br />
Tape Drive, SCSI-HVD<br />
CLUxxx-D3S.<br />
M SA<br />
Cable<br />
CLU180-D3S<br />
M SA<br />
CBL133-XX. Up to 80 feet.<br />
CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />
ADP 133-FMF for concatenation<br />
CLU201 - SDLT320<br />
Tape Drive, SCSI-HVD<br />
CLU201-D3S<br />
Partition Information<br />
CLU700-D3S CLU700 - SDLT320<br />
Tape Drive, SCSI-HVD<br />
M SA<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
ALP8436<br />
M SA<br />
DSI 36-track tabletop<br />
tape drive<br />
ALP8436-TDD<br />
M SA<br />
Cable<br />
DSI 36-track rack single<br />
mount tape drive<br />
ALP8436-RD<br />
M SA<br />
CBL133-XX. Up to 80 feet.<br />
CBL 13304-06Y <strong>and</strong> CBL 13314-08Y for dual initiator, or<br />
ADP 133-FMF for concatenation<br />
DSI 36-track, 10cartridge<br />
autoloader,<br />
tabletop<br />
ALP8436-TAS<br />
Partition Information<br />
M SA<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
DSI 36-track, 10cartridge<br />
autoloader,<br />
rack mount<br />
ALP8436-RAS<br />
M SA<br />
DSI 36-track dual (1<br />
drive <strong>and</strong> 10-cartridge)<br />
autoloader, rack mount<br />
ALP8436-RAD<br />
2–12 6871 6364–003
Qualified I/O Device Tables<br />
OST5136 Tape<br />
OST5136-MTS 36 track tape drive Partition Information<br />
M SA<br />
M SA<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
One rack mount 36<br />
track drive<br />
OST5136-1D0<br />
M SA<br />
One rack mount 36<br />
track drive with one<br />
autoloader<br />
OST5136-1D1<br />
M SA<br />
Two rack mount 36<br />
track drives<br />
OST5136-2D0<br />
M SA<br />
Two rack mount 36<br />
track drives with one<br />
autoloader<br />
OST5136-2D1<br />
M SA<br />
Two rack mount 36<br />
track drives with (2)<br />
autoloaders<br />
OST5136-2D2<br />
M SA<br />
Four rack mount 36<br />
track drives with four<br />
autoloaders<br />
OST5136-44<br />
M SA<br />
19U cabinet with one 36<br />
track drive<br />
OST5136-C10<br />
M SA<br />
19U cabinet with (2) 36<br />
track drive<br />
OST5136-C20<br />
M SA<br />
19U cabinet with (2) 36<br />
track drives with<br />
autoloader<br />
OST5136-C21<br />
6871 6364–003 2–13
Qualified I/O Device Tables<br />
OST5136 Tape<br />
Continued<br />
M SA<br />
Table top 36 track tape<br />
drive<br />
OST5136-T1<br />
M SA<br />
Table top 36 track tape<br />
drive with autoloader<br />
OST5136-TLC<br />
CTS5236 Tape<br />
M SA<br />
Two 36 track controller<br />
transport units, ten<br />
cartridge capacity with<br />
autoloader<br />
CTS5236-2SA<br />
M SA<br />
Two 36 track controller<br />
transport units <strong>and</strong> a<br />
library attachment kit for<br />
CLU6000 class tape<br />
libraries<br />
CTS5236-2S6<br />
Partition Information<br />
M SA<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
Two 36 track controller<br />
transport units <strong>and</strong> a<br />
library attachment kit for<br />
CLU1000 class tape<br />
libraries<br />
CTS5236-2S1<br />
M SA<br />
Four 36 track controller<br />
transport units <strong>and</strong> a<br />
library attachment kit for<br />
CLU6000 class tape<br />
libraries<br />
CTS5236-4S6<br />
M SA<br />
Four 36 track controller<br />
transport units <strong>and</strong> a<br />
library attachment kit for<br />
CTS5236-4S1<br />
2–14 6871 6364–003
Qualified I/O Device Tables<br />
CLU1000 class tape<br />
libraries<br />
CTS9840 Tape<br />
CTS9840-SD9 Single cartridge drive M SA<br />
CTS9840-SDL Single cartridge drive M SA<br />
CTS9840-SLL L SERIES M SA<br />
Single CTS9840 manual<br />
CTS9840-SR1<br />
M SA<br />
rack<br />
Partition Information<br />
Dual CTS9840 manual<br />
CTS9840-SR2<br />
M SA<br />
rack<br />
Control: MT1SCSI<br />
Unit Type: MT<br />
CTS9840-SRA Rack mount autoloader M SA<br />
M SA<br />
Rack mount manual<br />
loader<br />
CTS9840-SRM<br />
CTS9840-STA Table top autoloader M SA<br />
M SA<br />
CTS9840-STM Table top<br />
6871 6364–003 2–15
Qualified I/O Device Tables<br />
Table 2–3. Storage Area Network (SAN) Fibre Channel Disks<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
AMS Disk Array<br />
Q F<br />
Note: Peripheral Test Driver not supported.<br />
AMS200 AMS 200 Array Solution<br />
Q F<br />
Partition Information<br />
AMS500 (DF700M) AMS 500 Array Solution<br />
Q F<br />
Control: FC2 FCSCSI1 Unit Type: PK<br />
AMS1000 (DF700H) AMS 1000 Array Solution<br />
2–16 6871 6364–003
Qualified I/O Device Tables<br />
HDS USP Tagmastore <strong>and</strong> 9500 Thunder<br />
RAID Disk Array<br />
USP 100 Tagmastore Entry Cable<br />
Q F<br />
USP 600 Tagmastore Enhanced CBL171-xx<br />
Q F<br />
USP 1100 Tagmastore High End Protocol<br />
Q F<br />
9570V Thunder High End Fabric <strong>and</strong> arbitrated loop modes. No mixing of control types on Q F<br />
the same arbitrated loop. Quickloop connections are not<br />
9580V Thunder Ultra High End supported.<br />
Q F<br />
For Fabric connected configurations, the relationship of one<br />
9585V Thunder Ultra High End channel to up to two units should be maintained <strong>and</strong> it is<br />
recommended that they be placed in a zone. If more channels<br />
<strong>and</strong> units are attached to the same fabric they should each be<br />
in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be<br />
designed to h<strong>and</strong>le the additional units <strong>and</strong> channels.<br />
The use of 300GB-10 FC in the USP <strong>and</strong> the 250 GB SATA<br />
drives in the 9500 are restricted for use, due to the possibility<br />
of IO timeouts<br />
Q F<br />
Partition Information<br />
Control: FC2 FCSCSI1 Unit Type: PK<br />
6871 6364–003 2–17
Qualified I/O Device Tables<br />
M F<br />
Host-based mirroring required<br />
ESM7900 Fibre<br />
Channel Disk<br />
OSD18201-F96 18GB FC 520<br />
bytes/sector 10K<br />
M F<br />
Includes equivalent CSM7900 models.<br />
Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />
for fibre conversion.<br />
36GB FC, 520<br />
Bytes/sector 10K<br />
OSC36202-F94<br />
Protocols<br />
OSC73203-F94 73 GB FC, 520<br />
Bytes/sector 10K<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
M F<br />
Partition Information<br />
Control: FC2 OSRCTL<br />
Unit Type: PK<br />
EuroLogic JBD2000<br />
JBOD<br />
Cable<br />
M F<br />
CBL171-xx<br />
JBD2000 High<br />
Availability Enclosure,<br />
Dual Optical/Copper I/O<br />
Modules.<br />
JBD2022-HA<br />
Protocol<br />
M F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
JBD2000 High<br />
Availability Enclosure,<br />
Dual Optical/Optical I/O<br />
Modules<br />
JBD2040-HA<br />
Partition Information<br />
M F<br />
Control: FC2 FCSCSI1<br />
JBD2000 High<br />
Availability Expansion<br />
Enclosure, Dual<br />
Copper/Copper I/O<br />
Modules<br />
JBD2004-HA<br />
2–18 6871 6364–003
Qualified I/O Device Tables<br />
Unit Type: PK<br />
M F<br />
JBD2000 St<strong>and</strong>ard<br />
Availability Enclosure,<br />
Single Optical/Copper<br />
I/O Module<br />
JBD2011-SA<br />
M F<br />
St<strong>and</strong>ard Availability<br />
Enclosure, Single<br />
Optical/Optical I/O<br />
Module<br />
JBD2020-SA<br />
M F<br />
St<strong>and</strong>ard Availability<br />
Expansion Enclosure,<br />
Single Copper/Copper<br />
I/O Module<br />
JBD2002-SA<br />
EuroLogic JBD2000<br />
JBOD<br />
M F<br />
18GB 15K RPM disk,<br />
Factory Installed<br />
JBD201815-2F<br />
Cable<br />
M F<br />
CBL171-xx<br />
18GB 15K RPM disk,<br />
Field Upgrade<br />
JBD201815-2U<br />
M F<br />
Protocol<br />
36GB 15K RPM disk,<br />
Factory Installed<br />
JBD201815-2F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
M F<br />
Partition Information<br />
36GB 15K RPM disk,<br />
Field Upgrade<br />
JBD203615-2U<br />
M F<br />
Control: FC2 FCSCSI1<br />
2000 36GB 10K RPM<br />
disk, Factory Installed<br />
JBD203610-2F<br />
Unit Type: PK<br />
M F<br />
36GB 10K RPM disk,<br />
Field Upgrade<br />
JBD203610-2U<br />
6871 6364–003 2–19
Qualified I/O Device Tables<br />
EMC Clariion<br />
Subsystems<br />
CX3-20 CX3-20 SPE Host based mirroring or multipath license required. Q F<br />
CX3-40 CX3-40 SPE Cable<br />
Q F<br />
CX3-80 CX3-80 SPE CBL171-xx<br />
Q F<br />
Q F<br />
Protocols<br />
73GB 15K 520 BPS 4GB<br />
12 V<br />
CX-4G15-73<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Q F<br />
Partition Information<br />
146 GB 15K 520 BPS<br />
4GB 12V<br />
CX-4G15-146<br />
Control: FC2 OSRCTL<br />
Q F<br />
CX300 Fibre Channel<br />
2GB<br />
CXU3001-DPE<br />
Unit Type: PK<br />
Host based mirroring or multipath license required.<br />
Q F<br />
The CLARiiON CX300 is<br />
an entry-level member<br />
of the EMC CLARiiON<br />
CX series.<br />
CX300<br />
Cable<br />
CBL171-xx<br />
Q F<br />
Protocols<br />
The CLARiiON CX500 is<br />
a mid-level member of<br />
the EMC CLARiiON CX<br />
series.<br />
CX500<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Partition Information<br />
Q F<br />
Control: FC2 OSRCTL<br />
The CLARiiON CX700 is<br />
a high-end member of<br />
the EMC CLARiiON CX<br />
series.<br />
CX700<br />
Unit Type: PK<br />
Host based mirroring required.<br />
M F<br />
CX400 The CLARiiON CX400 is<br />
a mid-level member of<br />
2–20 6871 6364–003
Qualified I/O Device Tables<br />
Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />
for fibre conversion.<br />
the EMC CLARiiON CX<br />
series.<br />
Protocols<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
M F<br />
Partition Information<br />
The CLARiiON CX600 is<br />
a high-end member of<br />
the EMC CLARiiON CX<br />
series<br />
CX600<br />
Control: FC2 OSRCTL<br />
Unit Type: PK<br />
EMC Symmetrix<br />
Disk<br />
Brocade switch long-wave inputs <strong>and</strong> short-wave fibre output<br />
for fibre conversion.<br />
Protocols<br />
M F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
CAB82xx, CAB84xx,<br />
CAB85xx, CAB87xx <strong>and</strong><br />
CAB88xx Styles<br />
Symmetrix 5.0 <strong>and</strong> 5.5<br />
Partition Information<br />
Control: FC2 FCPK1EMC<br />
Unit Type: PK<br />
6871 6364–003 2–21
Qualified I/O Device Tables<br />
EMC DMX<br />
Symmetrix Series<br />
Disk Subsystem<br />
DMX800 Rack mount Q F<br />
DMX801 Rack mount Q F<br />
Q F<br />
Single cabinet. Includes<br />
models DMX1000,<br />
DMX1000-P2 <strong>and</strong><br />
DMX1000-M2<br />
DMX1000<br />
Protocols<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Partition Information<br />
Dual cabinet. Includes<br />
models DMX2000,<br />
DMX2000-P2,<br />
DMX2000-M2,<br />
DMX2000-3 (3-phase),<br />
DMX2000-P2-3 (3phase)<br />
<strong>and</strong> DMX2000-<br />
M2-3 (3-phase).<br />
DMX2000<br />
Control: FC2 FCPK1EMC<br />
F<br />
Q<br />
Unit Type: PK<br />
Q F<br />
Includes models<br />
DMX3000-3 (3-phase)<br />
<strong>and</strong> DMX3000-M2-3 (3phase).<br />
DMX3000<br />
Q F<br />
DMX1500 DMX3 Array Note: Peripheral Test Driver not supported<br />
2–22 6871 6364–003
Qualified I/O Device Tables<br />
DMX2500 DMX3 Array Q F<br />
DMX3500 DMX3 Array Partition Information<br />
Q F<br />
Control: FC2 FCPK1EMC<br />
Q F<br />
DMX4500 DMX3 Array<br />
Unit Type: PK<br />
6871 6364–003 2–23
Qualified I/O Device Tables<br />
Q F<br />
iQstor JBOD 4000<br />
JBD4000 RTS4001<br />
Factory Ship Drop Ship<br />
Styles Styles<br />
Q F<br />
Peripheral Test Driver<br />
Not <strong>Support</strong>ed<br />
4 gigabit FC base<br />
storage enclosure<br />
RTS412880-<br />
BAS<br />
JBD4000-<br />
BAS<br />
36 gigabyte 15K RPM<br />
4Gbit FC drive<br />
Q F<br />
Cable<br />
RTS4303615-<br />
4F<br />
JBD403615-<br />
4F<br />
CBL171-xx<br />
Protocol<br />
Q F<br />
73 gigabyte 15K RPM<br />
4Gbit FC drive<br />
RTS4307314-<br />
4F<br />
JBD407315-<br />
4F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Q F<br />
Partition Information<br />
146 gigabyte 15K<br />
RPM 4Gbit FC drive<br />
RTS4314615-<br />
4F<br />
JBD4014615-<br />
4F<br />
Control: FC2 FCSCSI1<br />
Q F<br />
Unit Type: PK<br />
Rack-mount kit for<br />
J2880<br />
RTS400012-<br />
RK<br />
JBD4000-<br />
RMK<br />
Q F<br />
FC4 optical SFP<br />
transceiver,<br />
850nm,LC<br />
RTS400150-<br />
SFP<br />
JBD4010-IF<br />
2–24 6871 6364–003
Qualified I/O Device Tables<br />
Table 2–4. SAN Fibre Channel Solid State Disks<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
DSI2100 Solid State Disk<br />
DSI2100-08 8GB unit, 1Gb interface M F<br />
Protocol<br />
M F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
16GB unit, 1Gb<br />
interface<br />
DSI2100-016<br />
Partition Information<br />
M F<br />
24GB unit, 1Gb<br />
interface<br />
DSI2100-24<br />
Control: FC2 FCPK1SCSI<br />
Unit Type: PK M F<br />
32GB unit, 1Gb<br />
interface<br />
DSI2100-032<br />
6871 6364–003 2–25
Qualified I/O Device Tables<br />
Q F<br />
DSI3200/DSI3250 Solid State Disk<br />
16 GB System, Unisys<br />
DSI3200-U16<br />
38271<strong>680</strong>-000DSI PN<br />
04DSI3200-U16<br />
Q F<br />
32 GB System, Unisys<br />
38271706-000DSI PN<br />
04DSI3200-U32<br />
DSI3200-U32<br />
Q F<br />
Protocol<br />
48 GB System, Unisys<br />
38271714-000DSI PN<br />
04DSI3200-U48<br />
DSI3200-U48<br />
Fabric <strong>and</strong> arbitrated loop modes<br />
Q F<br />
Partition Information<br />
64GB System, Unisys<br />
38271722-000DSI PN<br />
04DSI3200-U64<br />
DSI3200-U64<br />
Control: FC2 FCPK1SCSI<br />
Q F<br />
Unit Type: PK<br />
8 GB System, ITI<br />
38361465-000DSI PN<br />
04DSI3208-ITI<br />
DSI3208-ITI<br />
Q F<br />
16GB Exp Module<br />
38361515-000DSI PN<br />
04DSI32U16-MEM<br />
DSI3216-MEM<br />
Q F<br />
Dual Port 2GB FC<br />
interface 38361523-<br />
000DSI PN<br />
04DSI32U65-FC<br />
DSI3265-FC<br />
2–26 6871 6364–003
Qualified I/O Device Tables<br />
Table 2–5. SAN Fibre Channel Tape Drives <strong>and</strong> <strong>Libra</strong>ries<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
ALP360 SDLT<br />
Note: Low Voltage Differential (LVD) drives are not supported<br />
Cable<br />
CBL171-xx<br />
Protocols<br />
Q F<br />
Single SDLT600<br />
Rackmount FC, single<br />
node<br />
ALP360-1FS<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Partition Information<br />
Control = FC2 FCSCSIMT<br />
Unit Type: MT<br />
6871 6364–003 2–27
Qualified I/O Device Tables<br />
ALP360 SDLT<br />
Restrictions<br />
Mixing of ALP360 <strong>and</strong> other fibre channel control types on the same attach<br />
Loop is not allowed <strong>and</strong> restricted.<br />
Quickloop connections are not supported.<br />
It is the expected behavior of Fibre Channel tape units to report irrecoverable<br />
I/Os if a LIP (Loop Initialization Process) occurs after data transfer has started<br />
for either a read or write operation between the device <strong>and</strong> the host channel.<br />
If data transfer has not started between the device <strong>and</strong> the host channel, the<br />
I/O reporting the LIP as an outboard bus device reset will be retried.<br />
Q F<br />
For Fabric connected configurations, the relationship of one channel to up to<br />
two units should be maintained <strong>and</strong> it is recommended that they be placed in a<br />
zone. If more channels <strong>and</strong> units are attached to the same fabric they should<br />
each be in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to<br />
h<strong>and</strong>le the additional units <strong>and</strong> channels.<br />
Dual SDLT600<br />
Rackmount, FC, dual<br />
node<br />
ALP360-2FD<br />
The ALP360 does not utilize a Hard Addressing scheme for connection to<br />
FC_AL arbitrated loop. This device uses a Soft address scheme that starts the<br />
process of obtaining a loop address (soft) at the low end of the AL_PA table of<br />
AL_PA’s (i.e. starting at AL_PA =EF dec. 00). Based on this, the ALP360<br />
must be the only target device on the FC_AL to the host initiator when direct<br />
connect FC_AL mode is configured. And can only be configured using address<br />
0 for the control in a direct attach configuration. When using this device in a<br />
fabric configuration the WWID Port Name should be used in the configuration<br />
file.<br />
ALP360-RFD SDLT600 field upgrade,<br />
ALP360-1FS to ALP360-<br />
2FD<br />
2–28 6871 6364–003
Qualified I/O Device Tables<br />
CTS7840 Fibre<br />
Channel Tape<br />
Single drive for<br />
Protocol<br />
CTS7840-FDL<br />
M F<br />
CLU6000<br />
Arbitrated loop mode only<br />
CTS7840-FLL Single drive for CLU700 M F<br />
Partition Information<br />
CTS7840-FR1 FC rack, single M F<br />
Control = FC2 FCSCSIMT<br />
CTS7840-FR2 FC rack, dual<br />
M F<br />
Unit Type: MT<br />
CTS9840 Fibre<br />
Channel Tape<br />
M F<br />
Single rack mount with<br />
autoloader<br />
CTS9840-FRA<br />
M F<br />
Protocols<br />
Single drive for<br />
CLU9710<br />
CTS9840-FD9<br />
M F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Single drive for<br />
CLU9740 <strong>and</strong> CLU6000<br />
CTS9840-FDL<br />
Partition Information<br />
M F<br />
Control = FC2 FCSCSIMT<br />
Single drive for CLU180<br />
<strong>and</strong> CLU700<br />
CTS9840-FLL<br />
M F<br />
Unit Type: MT<br />
Single drive for<br />
CLU9710<br />
CTS9840-SD9<br />
M F<br />
Single drive for<br />
CLU9740 <strong>and</strong> CLU6000<br />
CTS9840-SDL<br />
6871 6364–003 2–29
Qualified I/O Device Tables<br />
CTS9840B Fibre<br />
Channel Tape<br />
M F<br />
FC Drive on<br />
CLU6000/9740 <strong>Libra</strong>ries<br />
Tray<br />
CTB9840-FDL<br />
Protocols<br />
M F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
FC Drive on<br />
CLU180/700<br />
<strong>Libra</strong>ries Tray<br />
CTB9840-FLL<br />
Partition Information<br />
M F<br />
Control = FC2 FCSCSIMT<br />
FC Drive Rack Mount<br />
Single.<br />
CTB9840-FR1<br />
M F<br />
Unit Type: MT<br />
FC Drive Rack Mount<br />
Dual<br />
CTB9840-FR2<br />
M F<br />
CTB9840-FTM FC Drive Table Top.<br />
CTB9840C Fibre<br />
Channel Tape<br />
Q F<br />
Protocols<br />
9840C FC Drive<br />
CLU9740/6000<br />
CTC9840-FDL<br />
Q F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
9840C FC Drive<br />
CLU180/700<br />
CTC9840-FLL<br />
Partition Information<br />
Q F<br />
Control = FC2 FCSCSIMT<br />
9840C FC Single rack<br />
mount Drive<br />
CTC9840-FR1<br />
Q F<br />
Unit Type: MT<br />
9840C Two RK MT<br />
Drives<br />
CTC9840-FR2<br />
2–30 6871 6364–003
Qualified I/O Device Tables<br />
CTB9940 Fibre<br />
Channel Tape<br />
Q F<br />
Protocols<br />
Drive on CLU6000/9740<br />
<strong>Libra</strong>ries Tray<br />
CTB9940-FDL<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Partition Information<br />
Q F<br />
Control = FC2 FCSCSIMT<br />
Drive on<br />
CLU180/700<strong>Libra</strong>ries<br />
Tray<br />
CTB9940-FLL<br />
Unit Type: MT<br />
Linear Tape-Open (LTO) Gen2 Tape Drive<br />
for CLU <strong>Libra</strong>ries<br />
Note: Low Voltage Differential (LVD) drives are not supported<br />
Protocols<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Q F<br />
HP LTO Gen2 drive on<br />
CLU180 tray<br />
CLU180-22F<br />
Partition Information<br />
Control = FC2 FCSCSIMT<br />
Unit Type: MT<br />
6871 6364–003 2–31
Qualified I/O Device Tables<br />
DSI2000/4000 Tape Products<br />
Note: Low Voltage Differential (LVD) drives are not supported<br />
Q F<br />
30-Cartridge Base<br />
<strong>Libra</strong>ry for LTO, LVD<br />
<strong>Libra</strong>ry Interface<br />
DSI2100-L30<br />
Protocols<br />
Q F<br />
52-Cartridge Base<br />
<strong>Libra</strong>ry for LTO, LVD<br />
library interface<br />
DSI2100-L60<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Partition Information<br />
Q F<br />
60-Cartridge Base<br />
<strong>Libra</strong>ry<br />
LTO, LVD library<br />
interface<br />
DSI4100-L60<br />
Control = FC2 FCSCSIMT<br />
Unit Type: MT<br />
Q F<br />
104-Cartridge Base<br />
<strong>Libra</strong>ry LTO, LVD library<br />
interface<br />
DSI4200-L12<br />
Q F<br />
LTO3, Native FC Drive<br />
Kit for DSI Revolution<br />
Tape <strong>Libra</strong>ry<br />
DSIF63-REV<br />
Q F<br />
FC Robotics Interface,<br />
shortwave, 2GB SFP<br />
(LTO Only<br />
DSI63-FB2<br />
Q F<br />
Partitioning Option for<br />
Revolution <strong>Libra</strong>ry<br />
DSI240-POC<br />
Q F<br />
DSI2100 to DSI2200<br />
Pass Thru Kit<br />
DSI2122-RVG<br />
Q F<br />
DSI4100 to DSI4200<br />
Pass Thru Kit<br />
DSI4142-RVG<br />
2–32 6871 6364–003
Qualified I/O Device Tables<br />
Q F<br />
DSI Fibre <strong>Libra</strong>ry<br />
Controller for use with<br />
optional DSI63-FB2 FC<br />
interface<br />
DSI1000-IPF<br />
Q F<br />
DSI LVD <strong>Libra</strong>ry<br />
Controller for use with<br />
Base Cartridge<br />
controller with LVD<br />
library interface<br />
DSI1000-IPV<br />
SUN/StorageTek FC Linear Tape-Open (LTO)<br />
Gen3 <strong>Libra</strong>ry<br />
LTO Gen3 For L180/700<br />
STK3001100-000<br />
Q F<br />
HP LTO Fibre I/F<br />
STK3001101-HPF<br />
Protocols<br />
StorageTek Label<br />
STK3001103-STK<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
LTO Gen3 Drive for<br />
SL500<br />
STK3001104-000<br />
Partition Information<br />
Q F<br />
HP LTO Fibre I/F<br />
STK3001105-HPF<br />
Control = FC2 FCSCSIMT<br />
StorageTek Label<br />
STK3001107-STK<br />
Unit Type: MT<br />
HP LTO Drive for<br />
SL8500<br />
STK3001108-000<br />
Q F<br />
HP LTO Fibre I/F<br />
STK3001109-HPF<br />
StorageTek Label<br />
STK3001110-STK<br />
6871 6364–003 2–33
Qualified I/O Device Tables<br />
Protocols<br />
Q F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
DSI Fibre Channel Linear Tape-Open (LTO)<br />
Gen2 Rack Mount Fibre Channel Tape Drive<br />
Single LTO2 Rack<br />
ALP60-1FS,<br />
mount, FC-AL Single<br />
Node<br />
Q F<br />
Partition Information<br />
Dual LTO2 Rack mount,<br />
FC-AL Dual Node<br />
ALP60-2FD<br />
Control = FC2 FCSCSIMT<br />
Q F<br />
Unit Type: MT<br />
FC, LTO2 Field<br />
Upgrade, ALP60-1FS to<br />
ALP60-2FD<br />
ALP60-RDF<br />
Protocols<br />
Q F<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
DSI Fibre Channel Linear Tape-Open (LTO)<br />
Gen2 Auto Loader Fibre Channel Tape<br />
Drive<br />
Removeable 30-<br />
ALP60-FAS<br />
Cartridge ACL, Dual<br />
LTO2 drive, FC-AL<br />
Partition Information<br />
Control = FC2 FCSCSIMT<br />
Q F<br />
Removeable 30-<br />
Cartridge ACL, single<br />
LTO2 drive, FC-AL<br />
ALP60-FAD<br />
Unit Type: MT<br />
2–34 6871 6364–003
Qualified I/O Device Tables<br />
Q F<br />
DSI Fibre Channel Linear Tape-Open (LTO)<br />
Gen3 Rack Mount Fibre Channel Tape Drive<br />
Single LTO3 Rack<br />
ALP63-1FS<br />
mount, FC-AL Single<br />
Node<br />
Q F<br />
Protocols<br />
Dual LTO3 Rack mount,<br />
FC-AL Dual Node<br />
ALP63-2FD<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
Q F<br />
Partition Information<br />
Single FC LTO3 30<br />
cartridge Autoloader<br />
ALP63-FAS<br />
Control = FC2 FCSCSIMT<br />
Q F<br />
Dual FC LTO3 30<br />
Cartridge Auto Loader<br />
FC<br />
ALP63-FAD<br />
Unit Type: MT<br />
Q F<br />
FC, LTO 3 Field<br />
Upgrade, ALP63-1FS to<br />
ALP63-2FD<br />
ALP63-FRD<br />
Q F<br />
ALP63-RDF FC, LTO 3 field upgrade<br />
6871 6364–003 2–35
Qualified I/O Device Tables<br />
STK SDLT600 Fibre Channel Tape Drive<br />
SDT600 Drive Tray for<br />
STK600601-000 CLU180/700/1400<br />
Q F<br />
Fibre Channel Interface<br />
STK600601-RFC<br />
Protocols<br />
StorageTek Label<br />
STK600601-TK0<br />
Fabric <strong>and</strong> arbitrated loop modes.<br />
SDLT600 Drive Tray for<br />
SL8500<br />
Partition Information<br />
STK600685-000<br />
Q F<br />
Control = FC2 FCSCSIMT<br />
Fibre Channel Interface<br />
STK600685-RFC<br />
Unit Type: MT<br />
Storage Tek Label<br />
STK600685-TK0<br />
SDLT600 Drive Tray for<br />
SL500<br />
STK650-000<br />
Q F<br />
Fibre Channel Interface<br />
STK650-BRF<br />
StorageTek Label<br />
STK650-STK<br />
2–36 6871 6364–003
Qualified I/O Device Tables<br />
Table 2–6. SAN Fibre Channel Switches<br />
Interface<br />
Status<br />
Status key: Q = qualified for use on the <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>, M = migration only, C = orderable CER, U =<br />
unknown<br />
Interface key: F= FC3-IOP, SA = SCSI Tape Applicance, S =Serial Attached SCSI, E = Ethernet Managed<br />
Switch<br />
Fabric Only<br />
Fibre Channel<br />
Switch (Brocade)<br />
Brocade firmware level 5.1.0a M F<br />
Brocade 3900 - 2Gb, 32<br />
ports, SFP (Fabric only)<br />
HSC30439-S32<br />
Brocade firmware level 5.1.0a M F<br />
Brocade 12000 SAN<br />
Switch, 2Gb 2x64-Ports.<br />
Core FC fabric, SFP<br />
(Fabric only)<br />
HSC3041200-D64<br />
Brocade firmware level 5.1.0a M F<br />
Brocade 12000 SAN<br />
Switch, 2Gb 1x32-Ports.<br />
Core FC fabric, SFP<br />
(Fabric only)<br />
HSC3041200-S32<br />
Brocade firmware level 5.1.0a M F<br />
Brocade 12000 SAN<br />
Switch, 2Gb 1x64-Ports.<br />
Core FC fabric, SFP<br />
(Fabric only)<br />
HSC3041200-S64<br />
Copper SFPs are not supported on this switch. M F<br />
Brocade 3250, 2 Gb, 8<br />
ports, SFP (Fabric only)<br />
HSC3043250-FF<br />
6871 6364–003 2–37
Qualified I/O Device Tables<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 4900 32 port<br />
switch, 4 GB 0 SFPs,<br />
includes: Web Tools <strong>and</strong><br />
zoning<br />
HSC30449-S32<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 4900 64 port<br />
switch, 4GB 0 SFPs,<br />
includes: Web Tools <strong>and</strong><br />
zoning<br />
HSC30449-S64<br />
Copper SFPs are not supported on this switch. M F<br />
Brocade 3252, 2 Gb, 8<br />
ports, SFP (Fabric only)<br />
HSC3043252-VL2<br />
Copper SFPs are not supported on this switch. M F<br />
Brocade 3850, 16 ports,<br />
full fabric (Fabric only)<br />
HSC3043850-FF<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 200e switch.<br />
8 active ports, zero<br />
eport, 1 power supply,<br />
zero SFPs, serial cable,<br />
software: Web Tools,<br />
Advanced Zoning.<br />
HSC304210-S08<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 200e switch. 8<br />
active ports, full fabric, 1<br />
power supply, zero<br />
SFPs, serial cable,<br />
software: Web Tools,<br />
Advanced Zoning<br />
HSC304220-S08<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 200e switch.<br />
16 active ports, full<br />
fabric, 1 power supply,<br />
zero SFPs. Serial cable,<br />
software: Web Tools,<br />
Advanced zoning.<br />
HSC304240-S16<br />
2–38 6871 6364–003
Qualified I/O Device Tables<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 4100 16 Port<br />
Switch<br />
HSC304120-B16<br />
Brocade firmware level 5.1.0a Q F<br />
Brocade 4100 32 Port<br />
Switch<br />
HSC304140-B32<br />
Brocade firmware level 3.2.1a M F<br />
HSC30432-S08 Brocade 3200 – 2 Gb, 8<br />
ports, SFP (fabric)<br />
Brocade firmware level 3.2.1a M F<br />
Brocade 3800 - 2 Gb, 16<br />
ports, SFP (fabric)<br />
HSC30438-S16<br />
M F<br />
HSC304900-UPG 8 Port Upgrade<br />
M F<br />
Fibre Channel 1, 2, &4<br />
Gb SFP<br />
HSC50404-SFS<br />
6871 6364–003 2–39
Qualified I/O Device Tables<br />
2–40 6871 6364–003
Section 3<br />
SCSI Device Guidelines<br />
Introduction<br />
This section covers SCSI Tape Appliance <strong>and</strong> the tape devices subsystems that use the<br />
wide SCSI <strong>and</strong> Ultra wide SCSI interfaces. The maximum data transfer rate for Ultra<br />
SCSI interface is 40 MB per second.<br />
The following are some SCSI configuration rules:<br />
Dual Initiator SCSI<br />
• The maximum end-to-end length of the Ultra or Wide SCSI Bus is 25 meters (80<br />
ft)<br />
• For connectivity, the maximum number of SCSI devices per bus is four (4).<br />
• For best performance, the maximum number of SCSI devices per bus is two (2).<br />
• Both ends of the SCSI bus must be terminated, with no mid-bus terminations.<br />
• Each device on the bus must have a unique SCSI ID.<br />
A SCSI Dual Initiator configuration has two different bus masters. Dual Initiator is<br />
typically employed so that two different systems can access the same Tape drives<br />
(though not at the same time).<br />
6871 6364–003 3–1
SCSI Device Guidelines<br />
Figure 3–1. Appliance Cabling – Dual Initiator Configuration with two Tape<br />
Appliances<br />
Terminators require consideration with dual initiator. Both ends of the SCSI bus are<br />
terminated, so the second bus master must have the terminator removed. Port D on<br />
the LVD-HVD Converter has no terminator <strong>and</strong> may be attached to the middle of the bus.<br />
Subsystem Configuration Guidelines<br />
Tape Storage Subsystems Configuration Guidelines<br />
The following tape drive subsystems are qualified on some of ClearPath systems<br />
covered by this guide. See Section 2 for current qualification status.<br />
3–2 6871 6364–003
DSI ALP60 Linear Tape Open (LTO) Gen2<br />
SCSI Device Guidelines<br />
Table 3-1 list the minimum system software levels required to configure an ALP60.<br />
QUALIFIED<br />
CONFIGURATIONS<br />
SYSTEM<br />
Table 3–1. Minimum Requirements for ALP60<br />
QUALIFIED RELEASE/CHANGE LEVEL<br />
SYSTEM<br />
HARDWARE, SOFTWARE<br />
LIBRA <strong>680</strong>/<strong>690</strong> ClearPath MCP 10.1:<br />
MCP IC 051.1A.84<br />
Load-Utils IC 051.1A.16<br />
Log-Tools IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ALP/SDLT320 Tape Subsystem<br />
ClearPath MCP 11.1:<br />
MCP IC 052.1A.17<br />
Load-Utils IC 052.1A.1<br />
Log-Tools IC 052.1A.3<br />
DumpAnalyzer IC 051.1A.1<br />
CONTROL-WARE<br />
FIRMWARE<br />
MCP Platform<br />
Firmware 1.1<br />
There are two OEM vendors of SDLT320-type tape drives. DSI drives are st<strong>and</strong>-alone<br />
(either rack mount or tabletop) drives, <strong>and</strong> StorageTek (STK) drives are installed in CLU<br />
<strong>Libra</strong>ries (CLU180, CLU201, <strong>and</strong> CLU700).<br />
DSI Super Digital Linear Tape ALP320 St<strong>and</strong>-Alone Tape Drives<br />
DSI drives are delivered with V56 firmware installed to be compatible with DLT4000<br />
formatted tapes. You must contact your Unisys representative to acquire V70 firmware if<br />
you want to run multiple initiators. Future firmware upgrades may incorporate both<br />
requirements, but at present you can run one or the other, but not both.<br />
Table 3-2 lists the minimum firmware <strong>and</strong> system software levels required to operate<br />
your system with the ALP320 st<strong>and</strong> alone tape drives.<br />
6871 6364–003 3–3
SCSI Device Guidelines<br />
Table 3–2. Minimum ClearPath System Software Required for DSI<br />
ALP320 <strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware Level<br />
ClearPath MCP 10.1:<br />
MCP IC 051.1A.84<br />
Load-Utils IC 051.1A.16<br />
Log-Tools IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1:<br />
MCP IC 052.1A.17<br />
Load-Utils IC 052.1A.1<br />
Log-Tools IC 052.1A.3<br />
DumpAnalyzer IC 051.1A.1<br />
MCP Platform Firmware 1.1<br />
Table 3-3 lists the available DSI drives. See Section 3 for each drive’s qualification status.<br />
Available cable styles for use on ALP320 are listed in Table 3-4.<br />
The following is the firmware version rules:<br />
• V56 – Drive is compatible with DLT4000 (DLT20C) formatted tapes, but multiple<br />
initiator operation is restricted.<br />
• V70 – Drive can operate in a multiple initiator environment, but is not compatible<br />
with DLT4000 (DLT20C) formatted tapes.<br />
3–4 6871 6364–003
Table 3–3. DSI ALP320 Styles<br />
Drive Style Name Description<br />
SCSI Device Guidelines<br />
ALP320 –RDD SDLT320 Rack Mount Tape Drive, SCSI-HVD (PN 3826 8454-<br />
000)<br />
ALP3202 -RMK ALP320 HVD 2 Drive Rack Mount Kit (Dual Buss) (PN 3826<br />
8488-000)<br />
ALP320 -TDD SDLT320 Single Tape Drive, Table Top SCSI-HVD (PN 3826<br />
8439-000)<br />
Table 3–4. SCSI-2W (Wide) Cable Styles for ALP320<br />
Cable Style Description<br />
CBL 13304-06Y Dual Initiate cable<br />
CBL 13314-08Y Dual Initiate cable<br />
ADP 133-FMF SCSI Concatenation cable<br />
CBL133-10 SCSI Wide 10Ft (3.04M)<br />
CBL133-20 SCSI Wide 20Ft (6.09M)<br />
CBL133-40 SCSI Wide 40Ft (12.19M)<br />
CBL133-60 SCSI Wide 60Ft 18.28M)<br />
CBL133-80 SCSI Wide 80Ft (24.38M)<br />
StorageTek (STK) Super Digital Linear Tape SDLT320 <strong>Libra</strong>ry Tape<br />
Drives<br />
STK drives are delivered with V70 firmware installed <strong>and</strong> is capable of running multiple<br />
initiators. You must contact your Unisys representative to acquire V56 firmware if you<br />
want the drive to be compatible with DLT4000 formatted tapes. Future firmware<br />
upgrades may incorporate both requirements, but at present you can run one or the<br />
other, but not both.<br />
Table 3-5 lists the minimum firmware <strong>and</strong> system software levels required to operate<br />
you system with the SDLT320 library drives.<br />
6871 6364–003 3–5
SCSI Device Guidelines<br />
Table 3–5. Minimum ClearPath System Software Required for STK<br />
SDLT320 <strong>Support</strong> for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware Level<br />
ClearPath MCP 10.1:<br />
MCP IC 051.1A.84<br />
Load-Utils IC 051.1A.16<br />
Log-Tools IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1:<br />
MCP IC 052.1A.17<br />
Load-Utils IC 052.1A.1<br />
Log-Tools IC 052.1A.3<br />
DumpAnalyzer IC 051.1A.1<br />
MCP Platform Firmware 1.1<br />
Table 3-6 lists the available STK drives. See Section 2 for each drive’s qualification status.<br />
Available cable styles for use on DLP320 are listed in Table 3-7.<br />
The following is the firmware version rules:<br />
• V70 – Drive can operate in a multiple initiator environment, but is not compatible<br />
with DLT4000 (DLT20C) formatted tapes.<br />
• V56 – Drive is compatible with DLT4000 (DLT20C) formatted tapes, but multiple<br />
initiator operation is restricted.<br />
Table 3–6. SDLT320 Styles<br />
Drive Style Name Description<br />
CLU180-D3S CLU180 - SDLT320 Tape Drive, SCSI-HVD (PN 68960343-<br />
000)<br />
CLU201-D3S CLU201 - SDLT320 Tape Drive, SCSI-HVD (PN 68960327-<br />
000)<br />
CLU700-D3S CLU700 - SDLT320 Tape Drive, SCSI-HVD (PN 68960368-<br />
000)<br />
3–6 6871 6364–003
Table 3–7. SCSI-2W (Wide) Cable Styles for DLP320<br />
Cable Style Description<br />
CBL 13304-06Y Dual Initiate cable<br />
CBL 13314-08Y Dual Initiate cable<br />
ADP 133-FMF SCSI Concatenation cable<br />
CBL133-10 SCSI Wide 10Ft (3.04M)<br />
CBL133-20 SCSI Wide 20Ft (6.09M)<br />
CBL133-40 SCSI Wide 40Ft (12.19M)<br />
CBL133-60 SCSI Wide 60Ft 18.28M)<br />
CBL133-80 SCSI Wide 80Ft (24.38M)<br />
DSI ALP8700 Tape Subsystem<br />
Restrictions<br />
Minimum System software <strong>and</strong> firmware levels:<br />
System Software Firmware<br />
MCP 10.1 MCP Platform Firmware 1.1<br />
MCP 11.0<br />
Table 3-8 contains the available cable styles for ALP8700.<br />
Table 3–8. SCSI-2W (Wide) Cable Styles for ALP8700<br />
Cable Style Description<br />
CBL133-10 SCSI Wide 10Ft (3.04M)<br />
CBL133-20 SCSI Wide 20Ft (6.09M)<br />
CBL133-40 SCSI Wide 40Ft (12.19M)<br />
CBL133-60 SCSI Wide 60Ft 18.28M)<br />
CBL133-80 SCSI Wide 80Ft (24.38M)<br />
SCSI Device Guidelines<br />
The ALP8700 is restricted to use in single initiator configurations only. Multi-Initiator<br />
configurations are not supported.<br />
6871 6364–003 3–7
SCSI Device Guidelines<br />
3–8 6871 6364–003
Section 4<br />
Fibre Channel Device Guidelines<br />
General<br />
FC3-IOP Fibre Channel adapters enable ClearPath hosts to interface to Fibre Channel<br />
protocol (FCP) peripherals <strong>and</strong> subsystems. FCP is defined as SCSI protocol over Fibre<br />
Channel. Peripherals are connected to a host using a serial interface on an arbitrated loop<br />
(FC_AL) or through a fabric.<br />
The FC3–IOP provides one Ethernet port connection <strong>and</strong> two Fibre Channel<br />
portconnections.<br />
The Gigabit Ethernet port provides external networking <strong>and</strong> ODT support. The<br />
portconnection can be either copper or optical at 1 Gb per second.<br />
The two Fibre Channel ports provide the interface to external I/O devices. Each of<br />
theFibre Channel ports provide an optical interface, with a transfer rate of either 1, 2, or 4<br />
Gbper second.<br />
Qualification Status<br />
Section 2 of this document lists which devices are supported on the FC3-IOP.<br />
6871 6364–003 4–1
Fibre Channel Device Guidelines<br />
Configuration Guideline<br />
Table 4–1. FC3-IOP Configuration Guidelines<br />
Area Guideline<br />
Maximum Interface<br />
Cable Length<br />
The following is the maximum uninterrupted length of<br />
each Fibre Channel cable type:<br />
Copper: 30 meters<br />
SW Laser 50 µm optical fiber: 100 meters @ 4 gigabit<br />
SW Laser 50 µm optical fiber: 300 meters @ 2 gigabit<br />
SW Laser 50 µm optical fiber: 500 meters @ 1 gigabit<br />
SW Laser 62.5 µm optical fiber: 50 meters @ 4 gigabit<br />
SW Laser 62.5 µm optical fiber: 300 meters @ 1 gigabit<br />
LW Laser 8 µm optical fiber: 10 kilometers<br />
Note: Maximum lengths may be exp<strong>and</strong>ed using<br />
Brocade’s Exp<strong>and</strong>ed Fibre Channel option.<br />
Connectivity Arbitrated Loop: The maximum number of ports on FC-AL<br />
is 126.<br />
Fabric: For a breakdown of fabric capabilities, see<br />
ClearPath Plus Servers <strong>Libra</strong> Modes <strong>680</strong> <strong>and</strong> <strong>690</strong><br />
Administration <strong>and</strong> Operations Guide.<br />
FC switch firmware All switches in a fabric must have compatible firmware<br />
levels for proper operation of the fabric. See ‘Brocade<br />
Fibre Channel Switches’ at the end of this section.<br />
Setting Up Storage Area Network Fabrics <strong>and</strong> Creating Zones<br />
For instructions on setting up fabrics <strong>and</strong> creating zones, see ClearPath Plus Servers<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong> Operations Guide (6870 3511).<br />
4–2 6871 6364–003
Fibre Channel Disk Subsystems<br />
Fibre Channel Device Guidelines<br />
Guidelines for Installing the Hitachi AMS Disk Array<br />
On the <strong>Libra</strong> <strong>680</strong>, the AMS disk array can only be connected to the host via a FC3-IOP.<br />
The following table describes the minimum software levels <strong>and</strong> deviations <strong>and</strong> risk<br />
assessments for migrating a AMS disk array to a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.<br />
Table 4–2. Minimum Software Levels for Configuring a AMS Disk Array<br />
Device System Software Firmware<br />
<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
servers<br />
ClearPath MCP 10.1<br />
ClearPath MCP 11.0<br />
Guidelines for Installing the EuroLogic JBD2000 JBOD Rack<br />
On the <strong>Libra</strong> <strong>680</strong>, the JBD2000 can only be connected to the host via a FC3-IOP. The<br />
following tables describe the minimum software levels <strong>and</strong> deviations <strong>and</strong> risk<br />
assessments for migrating a JBD2000 to a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong>.<br />
Table 4–3. Minimum Software Levels for Configuring a JBOD2000<br />
Device System Software Firmware<br />
<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
servers<br />
Restrictions<br />
ClearPath MCP 10.1<br />
ClearPath MCP 11.0<br />
• Host Interfaces are all optical Fibre Channel. Copper cables are only used to<br />
interconnect racks.<br />
• Splitting the JBOD2000 racks into two loops within the same rack it not supported.<br />
• When running on fabric <strong>and</strong> multiple Initiators are used, separate zones should be<br />
used from each initiator that overlap at the storage port so that initiators are not in<br />
the same zone. For instructions on setting up fabrics <strong>and</strong> creating zones, see<br />
ClearPath Plus Servers <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong><br />
Operations Guide.<br />
6871 6364–003 4–3<br />
1.1<br />
1.1
Fibre Channel Device Guidelines<br />
Guidelines for Installing the EMC Clariion CX3 Disk Array<br />
On the <strong>Libra</strong> <strong>680</strong>, the CX3 Disk Array can only be connected to the host via a FC3-IOP.<br />
The following table describes the minimum software levels for configuring a CX3 Disk<br />
Array.<br />
Table 4–4. Minimum Software Levels for Configuring a CX3 Disk Array<br />
Device System Software Firmware<br />
<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
servers<br />
Restrictions<br />
ClearPath MCP 10.0:<br />
MCP IC 051.1A.84<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.0<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
MCP Platform<br />
Firmware release<br />
1.1<br />
• Mixing of CX3-20/40/80, <strong>and</strong> other fibre channel control types on the same attach<br />
Loop is not allowed <strong>and</strong> not supported.<br />
• <strong>Support</strong>ed splits configurations for Raid group of 2 disks is16 splits, Raid group of 5<br />
disks is 32 splits, Raid group of 7 disks is 64 splits.<br />
• Configurations using single disks are not supported.<br />
• When the 300 GB 2 Gb fibre channel drive is used as a backend drive in the disk<br />
array, all the drives in that rack will default to 2 Gb loop speeds.<br />
Guidelines for Installing the iQstore JBOD 4000 Disk<br />
Subsystem<br />
On the <strong>Libra</strong> <strong>680</strong> <strong>and</strong> <strong>FS1800</strong>, the iQstore JBOD 4000 Disk Subsystem can only be<br />
connected to the host via a FC3-IOP. The following table describes the minimum<br />
software levels for configuring a iQstore JBOD 4000 Disk Subsystem.<br />
4–4 6871 6364–003
Fibre Channel Device Guidelines<br />
Table 4–5. Minimum Software Levels for Configuring a iQstore JBOD<br />
4000 Disk Subsystem<br />
Device System Software Firmware<br />
<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
servers<br />
<strong>FS1800</strong><br />
Restrictions<br />
ClearPath MCP 10.0:<br />
MCP IC 051.1A.84<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.0<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
ClearPath MCP 10.0:<br />
MCP IC 051.1A.101<br />
LOAD –UTILS IC 051.1A.17<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.0<br />
MCP IC 052.1A.32<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
MCP Platform<br />
Firmware release<br />
1.1<br />
MCP Platform<br />
Firmware release<br />
1.0<br />
On the <strong>Libra</strong> <strong>680</strong> <strong>and</strong> <strong>FS1800</strong>, the iQstore JBOD 4000 Disk Subsystem can only be<br />
connected<br />
• The use of direct attach configurations on the <strong>Libra</strong><br />
185/580/590/585/595/VSE500/FS1600 using the FCA1850-LC is restricted.<br />
• Drive Replacements on the <strong>Libra</strong>185/580/590/585/595/VSE500/FS1600 are restricted<br />
unless the entire JBOD 4000 rack is removed from use, or to times when the<br />
system I/O rate is very low.<br />
• Drive Replacements when the Brocade 3800/3200 switch is used, requires that the<br />
rack be taken out of service during the replacement.<br />
6871 6364–003 4–5
Fibre Channel Device Guidelines<br />
Operational Characteristics <strong>and</strong> Features<br />
• Mixing of JBOD 4000, <strong>and</strong> other fibre channel control types on the same attach Loop<br />
is not allowed <strong>and</strong> not supported.<br />
• When concatenating JBOD4000 racks, configurations of up to six racks<br />
concatenated in a direct connect configuration is supported, but in fabric<br />
configurations no more than two racks concatenated <strong>and</strong> connected to a switch port<br />
are supported.<br />
• JBOD4000/RTS4001 racks are only supported when configured using the HID<br />
address mode setting.<br />
• JBOD4000/RTS4001 racks cannot auto sense the fibre channel interface speed. The<br />
racks have a switch-able front panel setting for either 2 Gb or 4 Gb speed that sets<br />
all ports in the rack to that speed.<br />
• It is recommended to use a 4Gb Fibre channel HBA in the SBOD manager server in a<br />
direct connect configuration where monitoring is required. Otherwise using 2Gb<br />
Fibre Channel HBAs will require all the JBOD4000 racks connected to the HBA to be<br />
set to 2Gb fibre channel speeds.<br />
• The SBOD Manager Server must be rebooted any time physical changes are made<br />
to the SBOD environment to get the SBOD Manager to recognize the changes.<br />
• SBOD manager may lose socket connection after about 72 hours of continuous<br />
operation. A restart of the manager is required for continuation of monitoring.<br />
• Using SBOD manager version 5010, the Fibre Channel speed label <strong>and</strong> value is<br />
incorrectly shown as 6GB. This will be corrected to show 4Gb in a future release.<br />
4–6 6871 6364–003
Fibre Channel Device Guidelines<br />
CX300, CX500, <strong>and</strong> CX700 Open Storage RAID Subsystem<br />
Configuration Guidelines<br />
The following table describes the minimum software levels for configuring a CX300,<br />
CX500, or CX700 RAID subsystem.<br />
Table 4–6. Minimum Software Levels for Configuring a CX300,<br />
CX500, or CX700 on a <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware<br />
ClearPath MCP 10.1:<br />
MCP Platform<br />
MCP IC 051.1A.84<br />
Firmware 1.1<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
Fibre Channel Tape Subsystems<br />
CTS9840 Fibre Channel Tape Configuration<br />
The CTS9840 requires the use of control type FCSCSIMT in the PCD of the partition<br />
profile. The maximum number of drives per channel is two due to channel b<strong>and</strong>width<br />
limits. The mixing of CTS9840 <strong>and</strong> ESM7700 on the same loop is not allowed.<br />
The CTS9840 has two FC ports on the unit. Both ports can assess the drive but not at<br />
the same time. Only one port can be used. Port A is used for even numbered addresses<br />
<strong>and</strong> Port B is used for odd numbered addresses.<br />
Configure CTS9840A for Fabric<br />
To set the CTS9840A tape drive for Fabric, perform the following.<br />
Notes:<br />
• The tape drive must be a CTS9840A (STK part number 312102401) <strong>and</strong> must be at a<br />
minimum firmware level of R1.30.110f to install on the fabric.<br />
6871 6364–003 4–7
Fibre Channel Device Guidelines<br />
• For more information on configuring the CTS9840, refer to CTS9840 Cartridge Tape<br />
Subsystem Installation Guide (8999 5310).<br />
1. Take the drive offline.<br />
2. Go to the drive configuration menu for Fibre Channel.<br />
3. Go to the Port A <strong>and</strong> B Attributes <strong>and</strong> set Hard PA=Y. This will set the drive to<br />
ports to operate in FL_Port mode.<br />
4. Set the loop address.<br />
• For instructions on setting up fabrics <strong>and</strong> creating zones, see ClearPath Plus Servers<br />
<strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> System Administration <strong>and</strong> Operations Guide.<br />
CTS9840B Fibre Channel Tape Configuration Guidelines<br />
The CTS9840B requires the use of control type FCSCSIMT in the PCD of the partition<br />
profile.<br />
CTS9840C Fibre Channel Tape Configuration Guidelines<br />
The CTS9840C requires the use of control type FCSCSIMT in the PCD of the partition<br />
profile. Table 4-5 describes the minimum software levels for configuring a CTS9840C.<br />
Table 4–7. Minimum Software Levels for Configuring a CTS9840C on<br />
a <strong>Libra</strong>s <strong>680</strong>/<strong>690</strong><br />
System Software Firmware<br />
ClearPath MCP 10.1:<br />
MCP Platform<br />
MCP IC 051.1A.84<br />
Firmware 1.1<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
4–8 6871 6364–003
Fibre Channel Device Guidelines<br />
Fibre Channel Linear Tape-Open (LTO) Gen2 Tape Drive for CLU<br />
<strong>Libra</strong>ries<br />
Linear Tape-Open (LTO) Technology offers enterprise system environments a tape<br />
solution that addresses the performance, capacity, reliability <strong>and</strong> management issues<br />
faced when choosing a tape solution. LTO Technology is ideal in the SAN environment<br />
because it meets the special tape dem<strong>and</strong>s that SANs create.<br />
Similar to digital linear tape drives (DLT), LTO drives write data tracks in a linear,<br />
serpentine fashion. When the end of the tape is reached, the heads are repositioned<br />
above or below their current location, <strong>and</strong> recording resumes in the opposite direction.<br />
There are two Fibre Channel LTO drives supported on ClearPath enterprise servers: the<br />
CLU180-22F for CLU180 libraries <strong>and</strong> the CLU700-22F for CLU700 libraries.<br />
Tables 4-6 lists the software level qualified for use with the LTO drives.<br />
Table 4–8. Minimum Software Levels for Configuring a LTO Gen2 on a<br />
<strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware Level<br />
ClearPath MCP 10.1:<br />
MCP Platform Firmware 1.1M<br />
MCP IC 051.1A.84<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
LTO Gen2 Restrictions<br />
• Mixing of CLU180-22F, CLU700-22F, <strong>and</strong> other fibre channel control types on<br />
the same attach Loop is not allowed <strong>and</strong> restricted.<br />
• For Fabric connected configurations, the relationship of one channel to up to two<br />
units should be maintained <strong>and</strong> it is recommended that they be placed in a zone.<br />
If more channels <strong>and</strong> units are attached to the same fabric they should each be<br />
in their own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to h<strong>and</strong>le the<br />
additional units <strong>and</strong> channels. For instructions on setting up fabrics <strong>and</strong> creating<br />
zones, see ClearPath Plus Servers <strong>Libra</strong> <strong>Models</strong> <strong>680</strong> <strong>and</strong> <strong>690</strong> Administration <strong>and</strong><br />
Operations Guide.<br />
6871 6364–003 4–9
Fibre Channel Device Guidelines<br />
• When the CLU180-22F, CLU700-22F tape drive is used with fabric connections<br />
no changes to the default sets are required<br />
• To run in Direct attach (Arbitrated Loop), QuickLoop (Arbitrated Loop), Fabric<br />
<strong>Public</strong> Loop device (NL-Port), or as a Fabric (N-Port) device with the CLU180-22F,<br />
CLU700-22F. Either set a hard fibre channel address of 1 - 125 in either AL mode<br />
or in NL- Port fabric mode or by using an address of 126 allow the device to<br />
operate as a Fabric point to point N-port device.<br />
To set this value, on the front of the L700/L180 CLU <strong>Libra</strong>ry perform the<br />
following.<br />
1. Press Menu<br />
2. Select Configuration<br />
3. Select Drive configuration (note drive must be unloaded)<br />
4. Press the arrow buttons to scroll to the drive you wish to configure <strong>and</strong><br />
press the SELECT button (Should be an HP LTO2 Fiber I/F drive)<br />
5. Press the arrow buttons to scroll to the LOOP ID: setting <strong>and</strong> press select.<br />
6. A display indicating PORT A Loop ID should be shown.<br />
Valid HRD Addr 1-125<br />
To ENA HRD use 1-125<br />
To ENA SOFT use 126.<br />
Scroll up to Incr.<br />
Scroll down to Decr.<br />
Select to Save<br />
Menu to exit.<br />
Changing the value to 126 <strong>and</strong> pressing the menu to exit will then cause the<br />
LOOP ID displayed in the previous screen to display AUTO. The display will<br />
also indicate that the Hard Address has been disabled.<br />
DSI2000/4000 Tape <strong>Libra</strong>ry System<br />
Tables 4-7 lists the software level qualified for use with the DSI/2000/4000 drives.<br />
Table 4–9. Minimum Software Levels for Configuring a DSI2000/4000<br />
Tape <strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware Level<br />
ClearPath MCP 10.1:<br />
MCP IC 051.1A.84<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
Platform Firmware release 1.0<br />
4–10 6871 6364–003
Fibre Channel Device Guidelines<br />
Table 4–9. Minimum Software Levels for Configuring a DSI2000/4000<br />
Tape <strong>Libra</strong>ry system for <strong>Libra</strong> <strong>680</strong>/<strong>690</strong><br />
System Software Firmware Level<br />
ClearPath MCP 11.1<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
DSI2000/4000 Restrictions<br />
• Mixing of DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV tape drive,<br />
<strong>and</strong> other fibre channel control types on the same attach Loop is not allowed <strong>and</strong><br />
restricted.<br />
• Quickloop connections are not supported.<br />
• The DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV tape drive does<br />
not utilize a Hard Addressing scheme for connection to FC_AL arbitrated loop. This<br />
device uses a Soft address scheme that starts the process of obtaining a loop<br />
address (soft) at the high end of the AL_PA table of AL_PA’s starting at the first<br />
available address. For example, if one initiator were used in this configuration the<br />
starting loop address would be 124 or AL_PA=02, since the FCA1850-LC initiator<br />
would occupy address 125 or AL_PA=01. Based on this addressing scheme, the<br />
DSI2100, DSI2200, DSI4100, DSI4200 using the DSIF63-REV must be the only target<br />
device on the FC_AL to the host initiator when direct connect FC_AL mode is<br />
configured. If the Port WWID of the DSI2100, DSI2200, DSI4100, DSI4200 using<br />
the DSIF63-REV can be determined though the use of a switch, then that value can<br />
be used in the configuration file e.g.(.cef) instead of a loop address. When using this<br />
device in a fabric configuration the WWID Port Name should always be used in the<br />
configuration file.<br />
• For Fabric connected configurations, the relationship of one channel to up to two<br />
units should be maintained <strong>and</strong> it is recommended that they be placed in a zone. If<br />
more channels <strong>and</strong> units are attached to the same fabric they should each be in their<br />
own zone, <strong>and</strong> the fabric b<strong>and</strong>pass needs to be designed to h<strong>and</strong>le the additional<br />
units <strong>and</strong> channels.<br />
• Only one port on the DSIF63-REV should be in use, <strong>and</strong> the other port can only be<br />
used as a Hot St<strong>and</strong>by<br />
6871 6364–003 4–11
Fibre Channel Device Guidelines<br />
Brocade Fibre Channel Switches<br />
This subsection is a matrix of Brocade switches <strong>and</strong> Fibre Channel peripherals with<br />
ClearPath MCP servers. Table 4-8 lists the system software <strong>and</strong> firmware levels for<br />
operation with the switches in Table 4-9. Table 4-10 lists the storage devices <strong>and</strong> their<br />
firmware levels qualified to operate with the devices in Table 4-9..<br />
Table 4–10. <strong>Libra</strong> <strong>680</strong>/<strong>690</strong> System Software Levels for Operation with<br />
Brocade Switches<br />
System Software Firmware<br />
ClearPath MCP 10.1:<br />
System Release 1.1<br />
Platform Firmware 1.1<br />
MCP IC 051.1A.84<br />
LOAD –UTILS IC 051.1A.16<br />
LOG-TOOLS IC 051.1A.17<br />
DumpAnalyzer IC 051.1A.13<br />
ClearPath MCP 11.1<br />
MCP IC 052.1A.17<br />
LOAD –UTILS IC 052.1A.1<br />
LOG-TOOLS IC 052.1A.3<br />
DumpAnalyzer IC 052.1A.1<br />
4–12 6871 6364–003
Fibre Channel Device Guidelines<br />
Table 4–11. Qualified Brocade Switch Firmware Levels<br />
Switch Style Number Description Firmware<br />
HSC30449-S32 Brocade 4900<br />
32 Port Switch<br />
HSC30449-S64 Brocade 4900<br />
64 Port Switch<br />
HSC 3043252-VL2 Brocade 3252- 8 Port, 2switch<br />
limitation.<br />
HSC 3043250-FF Brocade 3250 - 8 Port, Full<br />
Fabric.<br />
HSC 3043850-FF Brocade 3850 - 16 Port Full<br />
Fabric.<br />
HSC30439-S32 Brocade 3900 - 32 Port<br />
Switch<br />
HSC3041200-D64 Brocade 12000 2 x 64 Ports<br />
Switch<br />
HSC3041200-S32 Switch 2Gb FC 1x32-Ports.<br />
Core FC fabric<br />
HSC3041200-S64 Switch 2Gb FC 1x64-Ports.<br />
Core FC fabric<br />
HSC50400-SWL Shortwave Laser SFP<br />
HSC50400-SFL Longwave Laser SFP<br />
HSC30438-S16 Brocade 3800 16 Port 2 Gb<br />
HSC30432-S08 Brocade 3200 8 Port 2 Gb<br />
HSC30428-S16 Brocade 2800 16 Port 1Gb<br />
HSC30424-S08<br />
Brocade 2400 8 Port 1Gb<br />
HSC30464-S64 Rack Mountable, 64 port<br />
Integrated 1Gb<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
5.1.0a<br />
v3.2.1<br />
v3.2.1<br />
v2.6.2a<br />
v2.6.2a<br />
v2.6.2a<br />
6871 6364–003 4–13
Fibre Channel Device Guidelines<br />
Table 4–12. Qualified Storage Device Firmware Levels<br />
Device Style Number Description<br />
CTS9840/CTS7840 FC Tape<br />
Firmware<br />
CTS9840-FDL<br />
FC Drive on<br />
1.34.154f<br />
CTS7840-FDL<br />
CLU6000/9740/1000<br />
<strong>Libra</strong>ries Tray Assembly<br />
CTS9840-FD9 FC Drive on CLU9710<br />
<strong>Libra</strong>ry Tray Assembly<br />
CTS9840-FRA Rackmount Autoloader with<br />
FC Drive<br />
CTS9840-FLL<br />
CTS7840-FLL<br />
FC Drive on L-Series <strong>Libra</strong>ry<br />
Tray Assembly<br />
CTS7840-FR1 FC Drive, Rack Mount,<br />
Single<br />
1.34.154f<br />
1.34.154f<br />
1.34.154f<br />
1.34.154f<br />
CTS7840-FR2 FC Drive, Rack Mount, Dual 1.34.154f<br />
CTS9840B FC Tape<br />
CTB9840-FDL FC, Drive on CLU6000/9740<br />
<strong>Libra</strong>ries Tray<br />
CTB9840-FLL FC, Drive on CLU180/700<br />
<strong>Libra</strong>ries Tray<br />
CTB9840-FR1 FC, Drive Rack Mount<br />
Single.<br />
1.34.352f<br />
1.34.352f<br />
1.34.352f<br />
CTB9840-FR2 FC, Drive Rack Mount Dual 1.34.352f<br />
CTB9840-FTM FC, Drive Table Top 1.34.352f<br />
CTS9840 FC Tape<br />
CTC9840-FDL FC Drive in CLU 9741 tray<br />
Mount<br />
CTC9840-FLL FC Drive in CLU 180/700<br />
tray Mount<br />
1.34.553<br />
1.34.553<br />
CTC9840-FR1 FC Single Drive 1.34.553<br />
4–14 6871 6364–003
Fibre Channel Device Guidelines<br />
Table 4–12. Qualified Storage Device Firmware Levels<br />
Device Style Number Description Firmware<br />
CTC9840-FR2 FC Rack Mount FC Drives 1.34.553<br />
CTB9940 FC Tape<br />
CTB9940-FDL FC, Drive on CLU6000/9740<br />
<strong>Libra</strong>ries Tray<br />
CTB9940-FLL FC, Drive on CLU180/700<br />
<strong>Libra</strong>ries Tray<br />
CLUxxx-22F LTO Tape<br />
CLU180-22 HP FC LTO Gen2 drive on<br />
CLU180 tray<br />
CLU700-22F HP FC LTO Gen2 drive on<br />
CLU700<br />
1.32.421<br />
1.32.421<br />
K3A1<br />
K3A1<br />
HDS AMS<br />
AMS200 AMS 200 Array 0732/A-M<br />
AMS500 AMS 500 Array 0732/A-M<br />
AMS1000 AMS 1000 Array 0732/A-M<br />
JBD2000 JBOD<br />
JBD2022-HA<br />
JBD2000 High Availability<br />
Enclosure, Dual<br />
Optical/Copper I/O Modules<br />
JBD2040-HA JBD2000 High Availability<br />
Enclosure, Dual<br />
Optical/Optical I/O Modules<br />
JBD2004-HA JBD2000 High Availability<br />
Expansion Enclosure, Dual<br />
Copper/Copper I/O<br />
Modules<br />
JBD2011-SA JBD2000 St<strong>and</strong>ard<br />
Availability Enclosure,<br />
Single Optical/Copper I/O<br />
Module<br />
JBD2020-SA JBD2000 St<strong>and</strong>ard<br />
Availability Enclosure,<br />
Single Optical/Optical I/O<br />
Module<br />
2GB-V2.5.0<br />
2GB-V2.5.0<br />
2GB-V2.5.0<br />
2GB-V2.5.0<br />
2GB-V2.5.0<br />
6871 6364–003 4–15
Fibre Channel Device Guidelines<br />
Table 4–12. Qualified Storage Device Firmware Levels<br />
Device Style Number Description Firmware<br />
JBD2002-SA JBD2000 St<strong>and</strong>ard<br />
Availability Expansion<br />
Enclosure, Single<br />
Copper/Copper I/O Module<br />
JBD201815-2F JBD2000 18GB 15K RPM<br />
disk, Factory Installed<br />
JBD201815-2F JBD2000 36GB 15K RPM<br />
disk, Factory Installed<br />
JBD203610-2F JBD2000 36GB 10K RPM<br />
disk, Factory Installed<br />
EMC CLARiiON Disk<br />
CX7001-DPE CX700 SPE HA W 8GB<br />
MEMORY<br />
CX700-SPE CX700-FD SPE8GB FIELD<br />
INS<br />
CX700-DAV CX700 DAE W OS<br />
FACTORY INSTALL<br />
CX7001-DAV CX700 DAE W OS<br />
FACTORY INSTALL<br />
CX5001-DPE CX500 FIBRE CHANNEL W<br />
4GB<br />
2GB-V2.5.0<br />
4–16 6871 6364–003<br />
0005<br />
0005<br />
0005<br />
CX700 Bundle<br />
02.19.700.5.030<br />
CX700 Bundle<br />
02.19.700.5.030<br />
CX700 Bundle<br />
02.19.700.5.030<br />
CX700 Bundle<br />
02.19.700.5.030<br />
CX500 Bundle<br />
02.19.500.5.030<br />
CX500-DPE CX500 FC 4G FIELD INST CX500 Bundle<br />
02.19.500.5.030<br />
CX3001-DPE CX300 FC 2GB CX300 Bundle<br />
02.19.300.5.030<br />
CX300-DPE CX300 3U DPE HA w/SPS,<br />
FIELD INSTALL<br />
CXR7310-2GF CHV 73Gb 10K 520BPS<br />
12V 2Gb<br />
CX300 Bundle<br />
02.19.500.5.030<br />
R570<br />
7A06
CXR14610-2GF 146GB 10K 520BPS 2Gb<br />
12V<br />
CX6001-SPE CX600 SPE, FACTORY<br />
INSTALL<br />
Fibre Channel Device Guidelines<br />
R570<br />
7A06<br />
CX600 Bundle<br />
02.19.600.5.030<br />
CX600-SPE CX600 FIELD INSTALL CX600 Bundle<br />
02.19.600.5.030<br />
CX600-DAV CX600-1 st DAE W/UNIVER CX600 Bundle<br />
02.19.600.5.030<br />
CX4001-DPE CX400 DPE CX400 Bundle<br />
02.19.400.5.030<br />
CX400-DPE CX400 DPE FIELD INSTALL CX400 Bundle<br />
02.19.400.5.030<br />
CXR3615-2GF 36GB 15K RPM<br />
CXR7315-2GF 73GB 15K RPM<br />
SYMM 5.0<br />
CAB8430-18<br />
CAB8430-36<br />
CAB8430-50<br />
CAB8730-18<br />
CAB8730-36<br />
CAB8730-50<br />
SYMM5.5<br />
CAB8230-XX<br />
CAB8530-XX<br />
CAB8830-XX<br />
EMC Disk Subsystems<br />
5566.22.17<br />
5568.47.17<br />
DMX3 5771.86.95<br />
DMX 800 5670<br />
DMX 801 5670<br />
DMX 1000 5670<br />
DMX 2000 5670<br />
6871 6364–003 4–17
Fibre Channel Device Guidelines<br />
DMX 3000 5670<br />
DMX1500 5771.81.90<br />
DMX2500 5771.81.90<br />
DMX3500 5771.81.90<br />
DMX4500 5771.81.90<br />
4–18 6871 6364–003
Appendix A<br />
Host Bus Adapter Cables<br />
Signal cables connect the server to the peripherals.<br />
Cables in this appendix include<br />
• SCSI host bus port<br />
• Fibre Channel<br />
• Keyboard, monitor, <strong>and</strong> mouse<br />
• LAN<br />
The cables <strong>and</strong> cable adapters listed are for the most typical applications. Some<br />
configurations might require additional adapters or terminators.<br />
When ordering peripheral signal cables, refer to the documentation for the peripheral<br />
device or subsystem. Some subsystems require two sets of cables. Some connections<br />
require adapters or adapter cables<br />
SCSI Host Bus Port<br />
The host bus ports are connected to external storage devices. When ordering cables,<br />
use the shortest cable length possible to connect components.<br />
Fibre Channel<br />
Refer to Section 3 for fibre channel interface characteristics <strong>and</strong> brocade switch options.<br />
For longwave requirements consult Unisys Sales <strong>Support</strong>.<br />
DB9-to-DB9 Cables<br />
You can connect either the equalized or nonequalized copper interface cables (See Table<br />
A–1). Dual-loop installations require two adapters <strong>and</strong> two cables per subsystem.<br />
Table A–1. Fibre Channel Copper Interface Cables<br />
Style Description<br />
CBL135-1 FC cable, 1-meter, unequalized<br />
6871 6364–003 A–1
Host Bus Adapter Cables<br />
DB9-to-HSSDC Cables<br />
Table A–1. Fibre Channel Copper Interface Cables<br />
Style Description<br />
CBL135-3 FC cable, 3-meter, unequalized<br />
CBL135-5 FC cable, 5-meter, unequalized<br />
CBL135-10 FC cable, 10-meter, unequalized<br />
CBL135-15 FC cable, 15-meter, unequalized<br />
CBL137-20 FC cable, 20-meter, equalized<br />
CBL137-25 FC cable, 25-meter, equalized<br />
CBL137-30 FC cable, 30-meter, equalized<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
Table A–2. DB9-to-HSSDC Fibre Channel Interface<br />
Cables<br />
Style Description<br />
CBL136-1 FC cable, 1-meter, unequalized<br />
CBL136-3 FC cable, 3-meter, unequalized<br />
CBL136-5 FC cable, 5-meter, unequalized<br />
CBL136-10 FC cable, 10-meter, unequalized<br />
CBL136-15 FC cable, 15-meter, unequalized<br />
CBL138-20 FC cable, 20-meter, equalized<br />
CBL138-25 FC cable, 25-meter, equalized<br />
CBL138-30 FC cable, 30-meter, equalized<br />
A–2 6871 6364–003
HSSDC-to-HSSDC Cables<br />
Host Bus Adapter Cables<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
HSSDC–2-to-DB9 Cables<br />
Table A–3. HSSDC-to-HSSDC Fibre Channel Interface<br />
Cables<br />
Style Description<br />
CBL147-1 FC cable, 1-meter, unequalized<br />
CBL147-3 FC cable, 3-meter, unequalized<br />
CBL147-5 FC cable, 5-meter, unequalized<br />
CBL147-10 FC cable, 10-meter, unequalized<br />
CBL147-15 FC cable, 15-meter, unequalized<br />
CBL148-20 FC cable, 20-meter, equalized<br />
CBL148-25 FC cable, 25-meter, equalized<br />
CBL148-30 FC cable, 30-meter, equalized<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
Table A–4. HSSDC–2-to-DB9 Fibre Channel Interface<br />
Cables<br />
Style Description<br />
CBL174-1 HSSDC-2 to DB9, 1-meter cable, 1 Gb<br />
CBL174-3 HSSDC-2 to DB9, 3-meter cable, 1 Gb<br />
CBL174-5 HSSDC-2 to DB9, 5-meter cable, 1 Gb<br />
CBL174-10 HSSDC-2 to DB9, 10-meter cable, 1 Gb<br />
6871 6364–003 A–3
Host Bus Adapter Cables<br />
HSSDC-to-HSSDC–2 Cables<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
Table A–5. HSSDC to HSSDC–2 Fibre Channel Interface<br />
Cables<br />
Style Description<br />
CBL175-1 HSSDC to HSSDC-2, 1-meter cable, 1 Gb<br />
CBL175-3 HSSDC to HSSDC-2, 3-meter cable, 1 Gb<br />
CBL175-5 HSSDC to HSSDC-2, 5-meter cable, 1 Gb<br />
CBL175-10 HSSDC to HSSDC-2, 10-meter cable, 1 Gb<br />
LC-to-SC, 1 Gb Shortwave Optical Cables<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
Table A–6. LC-to-SC Shortwave Optical Interface<br />
Cables<br />
Style Description<br />
CBL170-2 LC-to-SC shortwave cable, 2-meter, (1 Gb)<br />
CBL170-5 LC-to-SC shortwave cable, 5-meter, (1 Gb)<br />
CBL170-10 LC-to-SC shortwave cable, 10-meter, (1 Gb)<br />
CBL170-50 LC-to-SC shortwave cable, 50-meter, (1 Gb)<br />
CBL170-100 LC-to-SC shortwave cable, 100-meter, (1 Gb)<br />
CBL170-200 LC-to-SC shortwave cable, 200-meter, (1 Gb)<br />
CBL170-300 LC-to-SC shortwave cable, 300-meter, (1 Gb)<br />
CBL170-500 LC-to-SC shortwave cable, 500-meter, (1 Gb)<br />
A–4 6871 6364–003
LC-to-LC, Fibre Channel Optical Cables<br />
Host Bus Adapter Cables<br />
Dual-loop applications require two adapters <strong>and</strong> two cables per subsystem.<br />
Longwave Cables<br />
Table A–7. LC-to-LC Fibre Channel Optical Interface Cables<br />
Style Description<br />
CBL171-2 LC-to-LC shortwave cable, 2meter,<br />
(2 Gb or 4Gb)<br />
CBL171-5 LC-to-LC shortwave cable, 5meter,<br />
2 Gb or 4Gb)<br />
CBL171-10 LC-to-LC shortwave cable, 10meter,<br />
2 Gb or 4Gb)<br />
CBL171-25 LC-to-LC shortwave cable, 25meter,<br />
2 Gb or 4Gb)<br />
CBL171-50 LC-to-LC shortwave cable, 50meter,<br />
(2 Gb or 4Gb)<br />
CBL171-100 LC-to-LC shortwave cable, 100meter,<br />
2 Gb or 4Gb)<br />
CBL171-200 LC-to-LC shortwave cable, 200meter,<br />
(2 Gb only)<br />
CBL171-300 LC-to-LC shortwave cable, 300meter,<br />
(2 Gb only)<br />
For connecting from a disk<br />
array to a 2 Gb or 4 Gb<br />
switch or for connecting a<br />
FC3-IOP adapter to a 2Gb or<br />
4Gb switch or to the disk<br />
array.<br />
For installations where longwave cables are suitable, over 500 meters, Consult Unisys<br />
Sales <strong>Support</strong> for applicable cable styles <strong>and</strong> interface converters.<br />
Monitor, Keyboard, <strong>and</strong> Mouse<br />
The cables for the console components are not usually ordered separately. In a<br />
dual-domain configuration, if you do not use the display switch, you must use two sets<br />
of console components.<br />
Table A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables<br />
Style Description Notes<br />
KVM12-EXT Cable, keyboard, video, mouse<br />
extension, 12-feet<br />
This is a combination cable that<br />
extends the console component<br />
cables from the service<br />
processor or from the optional<br />
switch.<br />
6871 6364–003 A–5
Host Bus Adapter Cables<br />
Table A–8. Monitor, Keyboard, <strong>and</strong> Mouse Cables<br />
Style Description Notes<br />
CBL121-SWC Cable, keyboard, monitor, mouse cable,<br />
system-to-switch, 12-feet<br />
LAN<br />
This cable is part of the display<br />
switch package.<br />
In a dual-domain configuration, the CBL24-7 cable connects the two Uniscreen hubs.<br />
Table A–9. LAN Cables<br />
Style Description<br />
CBL24-7 Cable, 7-meter, cross-over, Ethernet 10/100 Base-T<br />
DSH600001-TBT Cable, 1-meter, straight through<br />
DSH600002-TBT Cable, 2-meter, straight through<br />
DSH600003-TBT Cable, 3-meter, straight through<br />
DSH600004-TBT Cable, 4-meter, straight through<br />
DSH600007-TBT Cable, 7-meter, straight through<br />
A–6 6871 6364–003
Index<br />
A<br />
Audience, 1-1<br />
C<br />
cable<br />
console components, A-5<br />
LAN, A-6<br />
SCSI host bus port, A-1<br />
Crypto Co-Processor, 2-3<br />
CTS9840 Fibre Channel Tape<br />
Configuration, 4-7<br />
CTS9840A, Configure for Fabric, 4-7<br />
D<br />
digital linear tape drives (DLT), 4-9<br />
E<br />
ePortal Hardware, 2-4<br />
F<br />
FC3-IOP, 2-8<br />
Fibre Channel - Arbitrated Loop topology (FC-<br />
AL), 4-1<br />
fibre channel adapter, 4-1<br />
Fibre Channel Protocol<br />
definition, 4-1<br />
L<br />
Linear Tape-Open (LTO) Technology, 4-9<br />
6871 6364–003 Index–1<br />
P<br />
Prerequisites, 1-1<br />
S<br />
SCSI Tape Appliance, 2-9<br />
Secure Maintenance Device, 2-3<br />
Serial Attached SCSI Feature, 2-8<br />
Super Digital Linear Tape, 3-3
Index<br />
Index–2 6871 6364–003
© 2007 Unisys Corporation.<br />
All rights reserved.<br />
*68716364-003*<br />
6871 6364–003