6. Install field-supplied conduit into the same<br />
hole as the original bushing for the chass<strong>is</strong><br />
pigtail wires on the control box.<br />
1. Field-supplied conduit<br />
2. Control box<br />
1<br />
2<br />
2-8<br />
7. Connect the chass<strong>is</strong> pigtail wires to the<br />
incoming power supply wires using the UL<br />
l<strong>is</strong>ted wire nuts (provided). Connect the<br />
black wire to the incoming L1 (black) wire.<br />
Connect the white wire to the incoming<br />
neutral (white) wire. Connect the green<br />
wire to the incoming ground (green or<br />
bare) wire.<br />
1. Black wire<br />
2. Incoming L1 wire (black wire)<br />
3. Green wire<br />
1 2 3 4 56<br />
4. Ground wire (green or bare wire)<br />
5. White wire<br />
6. Neutral wire (white wire)<br />
8. Reattach the PTAC/PTHP control panel<br />
using the 4 screws removed earlier.<br />
9. Reattach the PTAC/PTHP front cover using<br />
the thumbscrews removed earlier.<br />
10. Reconnect power.