Operator Presence Select a seat switch or operator<br />
activity monitor to detect operator presence.<br />
Disengagement Force Determines distance operator is<br />
required to move steering wheel to disengage. High<br />
setting will require more steering wheel motion before<br />
disengagement. Use high setting when rough conditions<br />
cause frequent disengagement of <strong>AutoTrac</strong> <strong>Universal</strong>.<br />
SETUP<br />
Steer Play Some vehicles may have excess play in their<br />
steering system which allows the steering wheel to be<br />
turned without change in the vehicle direction. This setting<br />
will control the distance that the steering wheel turns in<br />
order to take up this excess play. When ATU is placed on<br />
a machine that has excess play this setting should be<br />
used. This number should be set higher on vehicles which<br />
require greater steering wheel movement before the<br />
steering system responds. This setting should only be<br />
used on vehicles with excess play in their steering<br />
system. This number should be set to 0 on most vehicles<br />
except windrowers.<br />
IMPORTANT: Use <strong>AutoTrac</strong> <strong>Universal</strong> only on<br />
Approved Vehicles – see<br />
www.<strong>StellarSupport</strong>.com for list of<br />
approved vehicles<br />
It is important that the operator stay<br />
seated while vehicle is moving.<br />
When seat switch is chosen the<br />
external seat switch must be plugged<br />
into the <strong>AutoTrac</strong> <strong>Universal</strong> wiring<br />
harness. If operator leaves the seat for<br />
more than 7 seconds <strong>AutoTrac</strong> will be<br />
disengaged.<br />
When activity monitor is chosen<br />
<strong>AutoTrac</strong> <strong>Universal</strong> will look for<br />
operator activity every seven minutes.<br />
Operator will get a time out warning 15<br />
seconds before <strong>AutoTrac</strong> will<br />
disengage. Pressing resume will reset<br />
activity monitor timer.<br />
PC8941 –19–21FEB06<br />
OUO6050,0001AFA –19–20MAR06–5/5<br />
25-4 032206<br />