Description<br />

3.1 Features<br />

<strong>Device</strong> versions<br />

Table 3- 1 <strong>Device</strong> versions<br />

The device is available in the following versions:<br />

<strong>SENTRON</strong> <strong>PAC4200</strong> <strong>Power</strong> <strong>Monitoring</strong> <strong>Device</strong><br />

Order No. Description<br />

7KM4212-0BA00-2AA0 <strong>SENTRON</strong> <strong>PAC4200</strong> with ring lug terminals<br />

7KM4212-0BA00-3AA0 <strong>SENTRON</strong> <strong>PAC4200</strong> with screw terminals<br />

Measurement<br />

Sliding window demand values<br />

● Derivation of more than 300 measured variables from the basic measured variables with<br />

maximum and minimum values (slave pointer function).<br />

● At the voltage terminals, <strong>SENTRON</strong> <strong>PAC4200</strong> can be connected direct to 690 V industrial<br />

systems (max. 600 V for Vph, measuring category III, pollution degree 2). Higher voltages<br />

using voltage transformers.<br />

● For current transformers x/1 A and x/5 A. Conversion ratio and current direction<br />

programmable.<br />

● Can be used in 2-, 3- and 4-wire systems. Suitable for TN, TT and IT systems.<br />

● High measuring accuracy: For instance, accuracy class 0.2 in accordance with IEC<br />

61557-12 for the active energy, in other words accuracy equivalent to 0.2% of the<br />

measured value under reference conditions.<br />

● Calculation of the sliding window demand values for<br />

– Voltages and currents<br />

– <strong>Power</strong> factor per phase and total system<br />

– Apparent, active, and reactive power per phase as well as total power<br />

● Maximum and minimum values of the sliding window demand with the date and time of<br />

occurrence since startup, the last reset, or the last deletion<br />

● Demand calculation for reactive power VAR1, reactive power VARn, or total reactive<br />

power VARtot.<br />

● Configurable averaging time.<br />

Average values over all phases<br />

● Calculation of the average voltage and current values over all phases. The average value<br />

of a three or four-phase system corresponds to the arithmetic mean for the individual<br />

phase values.<br />

● Maximum and minimum average values with date and time.<br />

<strong>SENTRON</strong> <strong>PAC4200</strong><br />

18 <strong>Manual</strong>, 09/2008, A5E02316180B-01