2.2 ELECTRICAL CONNECTIONS<br />
WARNING<br />
Power Requirements<br />
NOTE<br />
CAUTION<br />
Disconnect primary power at the source before disassembling<br />
the power suply, torch or torch leads.<br />
The unit will operate from single phase 200V ±10%, 50/60 Hz.<br />
The service should be fused for 20 amps.<br />
Input power connections can be made directly to a properly<br />
fused disconnect or by using a plug which conforms to the<br />
recommended ratings.<br />
The attached AC input power cable is three conductor, 14 AWG.<br />
The primary power source, power cable, and plug all must<br />
conform to local elecric code and recommended circuit<br />
protection and wiring requirements.<br />
INSTALLATION 4 Manual 0-2462