Diagnostic OAE-Tympanometry<br />

Combination System<br />

<strong>Pro</strong><br />

ERO•SCAN<br />

• 3 tests with one probe fit<br />

• Electronic medical records (EMR), ready<br />

• Link results to patient's electronic chart<br />

with EroScan <strong>Pro</strong> software<br />

EroScan <strong>Pro</strong> Pictured<br />

by <strong>Maico</strong> <strong>Diagnostics</strong><br />

www.maico-diagnostics.com


Otoacoustic Emissions (OAEs)<br />

Otoacoustic emissions are sounds that are produced by the<br />

cochlea (outer hair cells) and can be measured in the ear canal.<br />

When sound passing through the ear canal reaches the cochlea,<br />

the vibration stimulates thousands of tiny hair cells. This creates<br />

a byproduct that can be detected and measured: otoacoustic<br />

emissions. OAEs only occur in a normal cochlea with normal<br />

hearing sensitivity. If there is damage to the outer hair cells,<br />

which produces hearing loss, then OAEs will not be present. In<br />

general, OAEs will be present if hearing is at 30 dB or better.<br />

www.maico-diagnostics.com


<strong>Pro</strong><br />

ERO•SCAN<br />

Why are OAEs Clinically Valuable?<br />

OAEs are widely applied in pediatric and adult patient populations<br />

for a variety of reasons. OAEs are an index of outer hair cell activity.<br />

Because of their dependence on normal cell metabolism, almost all<br />

insults to the cochlea first affect the outer hair cells. For example,<br />

vascular, noise damage or hypoxic cochlear deficits will be invariably<br />

reflected by reduced OAE amplitude. Therefore, assuming normal<br />

middle ear function, OAE abnormalities provide early and compelling<br />

evidence of cochlear (outer hair cell) dysfunction. Additional clinical<br />

advantages of OAE are:<br />

• Brief test time: Usually less than a minute per ear<br />

• Relatively simple technique: Little training is required<br />

• Objective: Unaffected by attention, cognition, cooperation<br />

• Independent of age: OAEs can even be recorded from<br />

newborn infants<br />

• Ear specific: Test results for each ear<br />

• Frequency specific: Information for many individual frequencies<br />

• Test up to 10 frequency bands as close as 100 Hz apart<br />

Clinical Applications of OAEs<br />

Given their sensitivity to cochlear dysfunction, and the clinical<br />

advantages, it’s not surprising that OAEs are useful in auditory<br />

assessment of diverse patient populations. One of the most<br />

common applications of OAEs is screening persons at risk for<br />

hearing impairment. OAE screening outcome is generally<br />

described as either “Pass” or “Refer.” A pass outcome is<br />

reported when OAEs are present (≥ 6 dB above the noise floor)<br />

for the majority of test frequencies. Although the presence of<br />

OAEs does not always indicate normal hearing sensitivity, a<br />

pass outcome rules out serious degrees of hearing loss. A refer<br />

OAE screening outcome should be viewed as a clear risk factor<br />

for hearing loss that could affect communication. Patients who<br />

yield a refer outcome for OAE screening should be referred for<br />

diagnostic hearing assessment, and possible audiological or<br />

medical management.


OAE Say Hello to Tympanometry<br />

Ero•Scan <strong>Pro</strong><br />

As a non-invasive test, tympanometry can quickly and easily be performed on<br />

patients of any age, from infants to adults. The objectivity of tympanometry<br />

means the results are not dependant upon a response from the patient.<br />

Advantages of Tympanometry:<br />

• Middle Ear evaluations<br />

• Objective test method<br />

• Test patients of any age<br />

• Documented test results<br />

Features of Ero Scan <strong>Pro</strong>:<br />

• Print to thermal paper, PDF, or 8.5 x 11 PC printer<br />

• Customizable settings and protocols<br />

• Optional patient management database<br />

• Sequenced protocols permit a full test battery<br />

www.maico-diagnostics.com<br />

Choose test to run (ie, linked OAE & Tymp)<br />

OAE “PASS” Result<br />

Tymp “PASS” Result<br />

OAE “REFER” Result<br />

Review Result<br />

EroScan <strong>Pro</strong> Screen Shots


The EroScan <strong>Pro</strong> is the only system that has<br />

the capability of linking DP & TE protocols for<br />

diagnostic cochlear mapping.<br />

The only OAE system that has the option of<br />

adding tympanometry in both 226Hz and<br />

1000Hz, probe tones.<br />

DPOAE/ TEOAE/TYMP<br />

• OAE and Tympanometry are completed in as little<br />

as 20 seconds<br />

• Intuitive interface for fast, easy operation<br />

• Advanced diagnostic capabilities<br />

• One probe fit, three tests; (CPT codes) 92567, 92587 &<br />

92588. Run three tests without taking probe out of the<br />

patient’s ear<br />

Portability<br />

The EroScan <strong>Pro</strong> hand-held unit runs on batteries and allows<br />

you to move from room to room. The probe also makes it<br />

easy to maneuver around the head of your patient to attain<br />

a tight ear seal.<br />

<strong>Pro</strong>tocols<br />

• Normative data included<br />

• Approved, verified protocols can be customized<br />

• Open templates that can be customized<br />

• Multiple customizable test protocols<br />

<strong>Pro</strong>tocols Screen Pictured<br />

<strong>Pro</strong><br />

ERO•SCAN<br />

Managing Data and Print Results<br />

Managing patient reports and tracking data is easy<br />

with the optional database. Selectable print options,<br />

are easily commanded by the push of one button.<br />

• Compatible with EMR via PDF<br />

• 8.5 x 11 full color PDF<br />

• Full page to PC printer<br />

• Customize report with office header information<br />

• Thermal paper print


<strong>Pro</strong><br />

ERO•SCAN<br />

Reimbursement<br />

Otoacoustic emissions are reimbursable using the Current<br />

<strong>Pro</strong>cedural Terminology (CPT) codes. To date, health care<br />

reimbursement has varied in terms of cost per test but no<br />

problems have arisen if the appropriate codes are utilized.<br />

The most typical CPT code for OAE screening is:<br />

92587:<br />

Evoked otoacoustic emissions; limited (single stimulus<br />

level, either transient or distortion product). This is the most<br />

typical code and would be considered a screening code or<br />

sampling of the cochlea.<br />

92588:<br />

Comprehensive or diagnostic evaluation (comparison of<br />

transient and/or distortion product otoacoustic emissions<br />

at multiple levels and frequencies). This is for diagnostic<br />

OAE testing, or mapping of the cochlea.<br />

92567:<br />

Tympanometry<br />

Conforms to IEC 601-1.<br />

ERO•SCAN is a trademark of ETYMOTIC RESEARCH, INC. Printed in the USA<br />

U.S. Patent #5,954,669; 6,299,584; 6,702,758; 6,056,698; 6,331,164; 7,050,592; 7,269,262,164 Other Patents Pending<br />

www.maico-diagnostics.com


Printer Kit #589-10 Cradle #589-2<br />

USB #1025-2088<br />

OAE External <strong>Pro</strong>be<br />

#589-1<br />

<strong>Pro</strong>be Tips (internal)<br />

#589-4<br />

Eartip Kit<br />

#589-7<br />

Patient Management<br />

Software<br />

(Includes Patient Management Manual)<br />

#589PM<br />

Printer Paper #586-8<br />

(adhesive or non-adhesive)<br />

Tymp/OAE<br />

External <strong>Pro</strong>be<br />

#589-3<br />

<strong>Pro</strong>be Tips (external)<br />

#589-5<br />

Carrying Case<br />

(optional accessory)<br />

#589-11<br />

Ero Scan <strong>Pro</strong><br />

Operation DVD<br />

#5577<br />

Parts & Accessories<br />

The ERO•SCAN <strong>Pro</strong> OAE System is available in three<br />

configurations: Screener, Standard and Clinical System<br />

PRODUCT FEATURE SCREENER STANDARD CLINICAL<br />

Internal OAE <strong>Pro</strong>be Y Y Y<br />

External OAE <strong>Pro</strong>be Y Y Y<br />

External Tymp <strong>Pro</strong>be Option Optional Optional Optional<br />

DPOAE/TEOAE DP or TE DP or TE DP and TE<br />

SYSTEM FEATURES SCREENER STANDARD CLINICAL<br />

Sequenced <strong>Pro</strong>tocols Y Y Y<br />

Quick-print to PDF Y Y Y<br />

Quick-print to PC Printer (8.5x11) Y Y Y<br />

Completely Portable Y Y Y<br />

Memory (# tests) Maximum 350 350 350<br />

Save Tests by Patient # Y Y Y<br />

Print Graphics and Numeric Data Y Y Y<br />

Date and Time on Printout Y Y Y<br />

Tests All Ages Y Y Y<br />

Printer Optional Optional Optional<br />

Patient Management Database<br />

w/ support for uploadng patient<br />

names to instrument<br />

Optional Optional Optional<br />

OAE FEATURES SCREENER STANDARD CLINICAL<br />

OAE Frequency Range (Hz)<br />

Maximum number of Test<br />

Frequencies or Bands Reported<br />

2-5 DP<br />

1.5-4 TE<br />

4 DP<br />

6 TE<br />

1.5-12 DP<br />

0.7-4 TE<br />

10 DP<br />

10 TE<br />

1.5-12 DP<br />

0.7-4 TE<br />

10 DP<br />

10 TE<br />

Default Pass/Refer Y Y Y<br />

# of OAE Test <strong>Pro</strong>tocols 2 Included 5 Included 5 DP, 5 TE Included<br />

Customizable Pass Criteria N Y Y<br />

Customizable Test <strong>Pro</strong>tocols N Y Y<br />

Customizable by frequency/range:<br />

stimulus intensity, P1/P2 ratio,<br />

averaging time, SNR for pass,<br />

minimum OAE amplitude<br />

Not Customizable Y Y<br />

Selectable Averaging Time Y Y Y<br />

TYMPANOMETRY OPTION SCREENER STANDARD CLINICAL<br />

<strong>Pro</strong>be Tone 226 Hz Y Y Y<br />

<strong>Pro</strong>be Tone 1000 Hz Y Y Y<br />

Default PASS/REFER Indicator & Box Y (226 Hz) Y Y<br />

Hide/Show PASS/REFER<br />

Indicator & Box<br />

Y Y Y<br />

Customizable Pass Criteria N Y Y<br />

# of Tymp <strong>Pro</strong>tocols<br />

2 (226 Hz)<br />

1 (1000 Hz)<br />

2 (226 Hz)<br />

1 (1000 Hz)<br />

2 (226 Hz)<br />

1 (1000 Hz)


Innovation,<br />

REV 9/10<br />

Continuity,<br />

Reliability,<br />

MAICO <strong>Diagnostics</strong><br />

7625 Golden Triangle Drive<br />

Eden Prairie, MN 55344<br />

Tel: 888-941-4201<br />

Fax: 952-903-4100<br />

Web: www.maico-diagnostics.com<br />

MAICO <strong>Pro</strong>duct Line:<br />

• Screening Audiometers<br />

• Diagnostic Audiometers<br />

• Middle Ear Analyzers<br />

• OAE Test Systems<br />

• PC Compatible <strong>Pro</strong>ducts<br />

• Newborn Hearing Screening<br />

This brochure contains only a small segment of the comprehensive<br />

product portfolio of MAICO. To find out more about other solutions,<br />

please contact us at:<br />

Telephone: 888-941-4201

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!