ALIGNMENT<br />
Adjust the angular error by placing<br />
shims under the bolts as required<br />
(negative bolt value means that shims<br />
should be added.) The angular error is<br />
displayed live in the first direction when<br />
the sensors are placed in position<br />
number 1, and in the second direction<br />
when they are placed in position<br />
number 2.<br />
Now adjust the parallel offset in both<br />
directions by moving the machine. The<br />
parallel offset is displayed live in the<br />
first direction when the sensors are<br />
placed in position number 1, and in the<br />
second direction when they are placed<br />
in position number 2.<br />
Check that both the angular value and<br />
the parallel offset lie within the required<br />
tolerances once the adjustments are<br />
completed.<br />
Alignment is now complete. To confirm<br />
the result, re-do the measurement.<br />