Air heating - Giordano Benicchi
Air heating - Giordano Benicchi
Air heating - Giordano Benicchi
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Marine <strong>heating</strong> system Installation Instructions<br />
Always assemble wall ducts with seals.<br />
5.3 Exhaust pipe<br />
5.3.1 Exhaust pipe<br />
Use 2-layer stainless steel flexible exhaust pipe.<br />
• Keep the exhaust pipe as short as possible (maximum exhaust pipe length: see device-specific<br />
installation instructions).<br />
• Route the exhaust pipe as straight as possible (permissible number of bends, smallest<br />
permissible curve radius: see device-specific installation instructions).<br />
• No contact with temperature-sensitive objects such as electrical cables, water pipes, plastic<br />
parts, sails or boat hull.<br />
• Minimum wall distance: ≥ 20 mm.<br />
• Minimum pipe diameters; see device-specific installation instructions.<br />
5.3.2 Exhaust gas pipes in personnel accommodation<br />
WARNING! Avoid installing the heater and exhaust pipes in personnel accommodation<br />
if possible. (Danger of suffocation if routing is inappropriate)<br />
• If unavoidable: use rigid stainless steel pipes with a wall thickness ≥ 1mm.<br />
• Replace pipes with new ones after ≤ 10 years.<br />
• Make the joints especially precise and gas tight.<br />
• Use high temperature resistant sealing compound.<br />
5.4 Exhaust pipe connections<br />
• When routing the exhaust pipes, pay attention: all connections must be sealed.<br />
• Use only Webasto ® approved hose connections. No hose clamps.<br />
•<br />
Permitted hose clamps for exhaust pipe mounting<br />
10 © Webasto Global Comfort Solutions ®