Glossary of Terms<br />

Glossary of Terms<br />

Air Chop - the process of mixing air and solvent<br />

together during the flush cycle to help clean the lines<br />

and reduce solvent usage.<br />

Air Chop Time- duration of each activation of the air<br />

purge valve during a chop sequence. User settable from<br />

0.0-99.9 seconds.<br />

Analog - relating to, or being a device in which data are<br />

represented by continuously variable, measurable,<br />

physical quantities, such as length, width, voltage, or<br />

pressure.<br />

Chop Time- refers to the total length of the chop<br />

sequence during a purge. User settable from 0-999 seconds.<br />

Closed Loop Flow Control - refers to the process<br />

when the flow rate is adjusted automatically to maintain<br />

a constant flow.<br />

Color/Catalyst Dump - refers to the time required to<br />

flush the lines from the color or catalyst change module<br />

to the mix manifold during a color or catalyst change.<br />

Color/Catalyst Fill - refers to the time required to fill the<br />

lines from the color or catalyst change module to the mix<br />

manifold.<br />

Coriolis Meter - a non-intrusive flow meter often used in<br />

low flow applications or with light viscosity, shear sensitive,<br />

or acid catalyzed materials. This meter uses vibration<br />

to measure flow.<br />

Digital Input and Output - a description of data which<br />

is transmitted as a sequence of discrete symbols, most<br />

commonly this means binary data represented using<br />

electronic or electromagnetic signals.<br />

Discrete I/O - refers to data that constitutes a separate<br />

entity and has direct communication to another control.<br />

Dose Size - the amount of resin (A) and catalyst (B) that<br />

is dispensed into an integrator.<br />

Dose Time Alarm - the amount of time that is allowed<br />

for a dose to occur before an alarm occurs.<br />

Dynamic Dosing - Component A dispenses constantly.<br />

Component B dispenses intermittently in the necessary<br />

volume to attain the mix ratio.<br />

Ethernet - a method for directly connecting a computer<br />

to a network or equipment in the same physical location.<br />

Fiber Optic Communication - the use of light to transmit<br />

communication signals.<br />

Final Purge Source- source of the media used in the<br />

final purge cycle. User settable to air purge valve, solvent<br />

purge valve, or 3rd purge valve.<br />

Final Purge Time- duration of the final purge cycle.<br />

User settable from 0-999 seconds.<br />

First Purge Source- source of the media used in the<br />

first purge cycle. User settable to air purge valve, solvent<br />

purge valve, or 3rd purge valve<br />

First Purge Time- duration of the first purge cycle. User<br />

settable from 0-999 seconds.<br />

Flow Control Resolution - a settable value that allows<br />

the flow control system to maximize its performance.<br />

The value is based on maximum desired flow rates.<br />

Flow Rate Analog Signal - the type of communication<br />

signal that can be used on the ProControl module.<br />

Flow Rate Tolerance - the settable percent of acceptable<br />

variance that the system will allow before a flow<br />

rate warning occurs.<br />

Flow Set Point - a predefined flow rate target.<br />

Flush Volume Check - system monitors flush volume.<br />

E-11 Alarm occurs if minimum volume is not achieved.<br />

Minimum flush volume is user settable (0-999 cc).<br />

Grand Total - a non-resettable value that shows the<br />

total amount of material dispensed through the system.<br />

Gun Trigger Input Signal - used to manage ratio assurance<br />

dose times and flow control processes.<br />

Intrinsically Safe (IS) - refers to the ability to locate certain<br />

components in a hazardous location.<br />

Idle - if the gun is not triggered for 2 minutes the system<br />

enters Idle mode. Trigger the gun to resume operation.<br />

12 <strong>312779D</strong>