Glossary of Terms<br />
Glossary of Terms<br />
Air Chop - the process of mixing air and solvent<br />
together during the flush cycle to help clean the lines<br />
and reduce solvent usage.<br />
Air Chop Time- duration of each activation of the air<br />
purge valve during a chop sequence. User settable from<br />
0.0-99.9 seconds.<br />
Analog - relating to, or being a device in which data are<br />
represented by continuously variable, measurable,<br />
physical quantities, such as length, width, voltage, or<br />
pressure.<br />
Chop Time- refers to the total length of the chop<br />
sequence during a purge. User settable from 0-999 seconds.<br />
Closed Loop Flow Control - refers to the process<br />
when the flow rate is adjusted automatically to maintain<br />
a constant flow.<br />
Color/Catalyst Dump - refers to the time required to<br />
flush the lines from the color or catalyst change module<br />
to the mix manifold during a color or catalyst change.<br />
Color/Catalyst Fill - refers to the time required to fill the<br />
lines from the color or catalyst change module to the mix<br />
manifold.<br />
Coriolis Meter - a non-intrusive flow meter often used in<br />
low flow applications or with light viscosity, shear sensitive,<br />
or acid catalyzed materials. This meter uses vibration<br />
to measure flow.<br />
Digital Input and Output - a description of data which<br />
is transmitted as a sequence of discrete symbols, most<br />
commonly this means binary data represented using<br />
electronic or electromagnetic signals.<br />
Discrete I/O - refers to data that constitutes a separate<br />
entity and has direct communication to another control.<br />
Dose Size - the amount of resin (A) and catalyst (B) that<br />
is dispensed into an integrator.<br />
Dose Time Alarm - the amount of time that is allowed<br />
for a dose to occur before an alarm occurs.<br />
Dynamic Dosing - Component A dispenses constantly.<br />
Component B dispenses intermittently in the necessary<br />
volume to attain the mix ratio.<br />
Ethernet - a method for directly connecting a computer<br />
to a network or equipment in the same physical location.<br />
Fiber Optic Communication - the use of light to transmit<br />
communication signals.<br />
Final Purge Source- source of the media used in the<br />
final purge cycle. User settable to air purge valve, solvent<br />
purge valve, or 3rd purge valve.<br />
Final Purge Time- duration of the final purge cycle.<br />
User settable from 0-999 seconds.<br />
First Purge Source- source of the media used in the<br />
first purge cycle. User settable to air purge valve, solvent<br />
purge valve, or 3rd purge valve<br />
First Purge Time- duration of the first purge cycle. User<br />
settable from 0-999 seconds.<br />
Flow Control Resolution - a settable value that allows<br />
the flow control system to maximize its performance.<br />
The value is based on maximum desired flow rates.<br />
Flow Rate Analog Signal - the type of communication<br />
signal that can be used on the ProControl module.<br />
Flow Rate Tolerance - the settable percent of acceptable<br />
variance that the system will allow before a flow<br />
rate warning occurs.<br />
Flow Set Point - a predefined flow rate target.<br />
Flush Volume Check - system monitors flush volume.<br />
E-11 Alarm occurs if minimum volume is not achieved.<br />
Minimum flush volume is user settable (0-999 cc).<br />
Grand Total - a non-resettable value that shows the<br />
total amount of material dispensed through the system.<br />
Gun Trigger Input Signal - used to manage ratio assurance<br />
dose times and flow control processes.<br />
Intrinsically Safe (IS) - refers to the ability to locate certain<br />
components in a hazardous location.<br />
Idle - if the gun is not triggered for 2 minutes the system<br />
enters Idle mode. Trigger the gun to resume operation.<br />
12 <strong>312779D</strong>