Setup Mode<br />
NOTE: Each screen displays the current screen number<br />
and the total number of screens in the group. The total<br />
number of screens in a group and the fields displayed<br />
on each screen may vary depending on selections<br />
made in the System Configuration Screens and<br />
Option Screens.<br />
Recipe Setup Screen 2<br />
Recipe Setup Screen 1<br />
FIG. 51. Recipe Setup Screen 2<br />
FIG. 50. Recipe Setup Screen 1<br />
Ratio<br />
Enter the mix ratio of component A over component B<br />
(0.0:1 to 50:1).<br />
Ratio Tolerance<br />
Enter the ratio tolerance (1 to 99%). This refers to the<br />
percent of acceptable variance that the system will allow<br />
before a ratio alarm occurs.<br />
Component A (Color) Valve (if present)<br />
This field only appears if the system includes a color<br />
change module. Enter the color valve number (1 to 30).<br />
Component B (Catalyst) Valve (if present)<br />
This field only appears if the system includes a color<br />
change module. Enter the catalyst valve number (1 to<br />
4).<br />
Minimum Flush Volume<br />
This field only appears if Flush Volume Check is set to<br />
“On” in Option Screen 1 on page 36. Enter the minimum<br />
flush volume (0 to 999 cc). Entering 0 disables this<br />
function.<br />
Potlife Time<br />
Enter the potlife time (0 to 999 minutes). Entering 0 disables<br />
this function.<br />
Color/Catalyst Purge<br />
This field only appears if the system includes a color<br />
change module and Flush and Fill Input is set to “Recipe”<br />
in Option Screen 1, page 36. Enter the purge time<br />
(0 to 99 seconds). It refers to the amount of time<br />
required to flush the lines from the color or catalyst module<br />
to the dose valve or dump valve.<br />
Color/Catalyst Fill<br />
This field only appears if the system includes a color<br />
change module and Flush and Fill Input is set to “Recipe”<br />
in Option Screen 1, page 36. Enter the fill time (0<br />
to 99 seconds). It refers to the time required to fill the<br />
lines from the color or catalyst module to the dose valve<br />
or dump valve.<br />
44 <strong>312779D</strong>