Setup Mode<br />

NOTE: Each screen displays the current screen number<br />

and the total number of screens in the group. The total<br />

number of screens in a group and the fields displayed<br />

on each screen may vary depending on selections<br />

made in the System Configuration Screens and<br />

Option Screens.<br />

Recipe Setup Screen 2<br />

Recipe Setup Screen 1<br />

FIG. 51. Recipe Setup Screen 2<br />

FIG. 50. Recipe Setup Screen 1<br />

Ratio<br />

Enter the mix ratio of component A over component B<br />

(0.0:1 to 50:1).<br />

Ratio Tolerance<br />

Enter the ratio tolerance (1 to 99%). This refers to the<br />

percent of acceptable variance that the system will allow<br />

before a ratio alarm occurs.<br />

Component A (Color) Valve (if present)<br />

This field only appears if the system includes a color<br />

change module. Enter the color valve number (1 to 30).<br />

Component B (Catalyst) Valve (if present)<br />

This field only appears if the system includes a color<br />

change module. Enter the catalyst valve number (1 to<br />

4).<br />

Minimum Flush Volume<br />

This field only appears if Flush Volume Check is set to<br />

“On” in Option Screen 1 on page 36. Enter the minimum<br />

flush volume (0 to 999 cc). Entering 0 disables this<br />

function.<br />

Potlife Time<br />

Enter the potlife time (0 to 999 minutes). Entering 0 disables<br />

this function.<br />

Color/Catalyst Purge<br />

This field only appears if the system includes a color<br />

change module and Flush and Fill Input is set to “Recipe”<br />

in Option Screen 1, page 36. Enter the purge time<br />

(0 to 99 seconds). It refers to the amount of time<br />

required to flush the lines from the color or catalyst module<br />

to the dose valve or dump valve.<br />

Color/Catalyst Fill<br />

This field only appears if the system includes a color<br />

change module and Flush and Fill Input is set to “Recipe”<br />

in Option Screen 1, page 36. Enter the fill time (0<br />

to 99 seconds). It refers to the time required to fill the<br />

lines from the color or catalyst module to the dose valve<br />

or dump valve.<br />

44 <strong>312779D</strong>