Setup Mode<br />
Recipe 0 Screen 3<br />
Recipe 0 Screen 4<br />
FIG. 60. Recipe 0 Screen 4<br />
FIG. 59. Recipe 0 Screen 3<br />
This screen only appears if Solvent Monitor is set to<br />
“Meter” in Configure Screen 5, page 34 and Flush Volume<br />
Check is set to “On” in Option Screen 1, page 36<br />
or 3rd Flush Valve is set to “On” in Configure Screen 3<br />
on page 33.<br />
This screen appears only if Flush and Fill Input is set to<br />
“Recipe” in Option Screen 1, page 36 and Special Outputs<br />
is set to 1, 2, 3, or 4 in Configure Screen 5, page<br />
34. The I/O board has four programmable outputs.<br />
Minimum Flush Volume<br />
This field only appears if Flush Volume Check is set to<br />
“On” in Option Screen 1 on page 36. Enter the minimum<br />
flush volume (0 to 999 cc).<br />
Exiting Fill Source<br />
This field only appears if 3rd Flush Valve is set to “On” in<br />
Configure Screen 3 on page 33. Select “Off,” “Air,” “Solvent,”<br />
or “3rd Valve.”<br />
Exiting Fill Time<br />
This field only appears if Exiting Fill Source is set to<br />
“Air,” “Solvent,” or “3rd Valve.” Enter the time in seconds.<br />