<strong>Guide</strong> <strong>to</strong> <strong>the</strong> <strong>Safety</strong>, <strong>Health</strong> <strong>and</strong> <strong>Welfare</strong> <strong>at</strong> <strong>Work</strong> (<strong>General</strong> Applic<strong>at</strong>ion)<br />

In some instances <strong>the</strong> use of ladders or safety harnesses may be acceptable but <strong>the</strong>ir use should be<br />

reviewed in <strong>the</strong> context th<strong>at</strong> <strong>the</strong>re may be safer options.<br />

BS 8213-1:2004 provides useful inform<strong>at</strong>ion when considering access options for window cleaning.<br />

Regul<strong>at</strong>ion 11: Doors <strong>and</strong> g<strong>at</strong>es<br />

11. An employer shall ensure th<strong>at</strong>—<br />

(a) <strong>the</strong> position, number <strong>and</strong> dimensions of doors <strong>and</strong> g<strong>at</strong>es, <strong>and</strong> <strong>the</strong> m<strong>at</strong>erials used in <strong>the</strong>ir<br />

construction, are determined by <strong>the</strong> n<strong>at</strong>ure <strong>and</strong> use of <strong>the</strong> rooms or areas <strong>and</strong> are<br />

appropri<strong>at</strong>e for <strong>the</strong> safety, health <strong>and</strong> welfare of employees,<br />

Doors <strong>and</strong> g<strong>at</strong>es installed in places of work should be suitable for <strong>the</strong> number of persons employed <strong>and</strong><br />

<strong>the</strong> n<strong>at</strong>ure of <strong>the</strong> work carried on. Fac<strong>to</strong>rs which should be taken in<strong>to</strong> account are <strong>the</strong> traffic routes used<br />

by pedestrians <strong>and</strong> vehicles, access for people with disabilities, requirements in <strong>the</strong> event of an<br />

emergency, visibility issues, n<strong>at</strong>ure of vehicular traffic, <strong>the</strong> numbers of employees requiring access or<br />

egress, <strong>the</strong> size <strong>and</strong> quantity of m<strong>at</strong>erial moving in <strong>and</strong> out of <strong>the</strong> workplace <strong>and</strong> <strong>the</strong> effort required <strong>to</strong><br />

open/close g<strong>at</strong>es.<br />

In some instances doors may require a certain fire r<strong>at</strong>ing <strong>to</strong> maintain a secure means of escape in case<br />

of fire.<br />

The Building Regul<strong>at</strong>ions Technical Guidance Document B: Fire <strong>Safety</strong> sets out a range of criteria th<strong>at</strong><br />

will influence <strong>the</strong> siting of doors.<br />

(b) swing doors <strong>and</strong> swing g<strong>at</strong>es are transparent or have see-through panels,<br />

(c) transparent doors are appropri<strong>at</strong>ely marked <strong>at</strong> a conspicuous level,<br />

So as <strong>to</strong> prevent employees walking through <strong>the</strong>m, <strong>the</strong> markings on transparent doors should be<br />

conspicuous <strong>and</strong> not easily removable.<br />

The Building Regul<strong>at</strong>ions Technical Guidance Document M: Access for People with Disabilities<br />

advises th<strong>at</strong> permanent markings be placed 1,200 <strong>to</strong> 1,500 mm above finished floor level.<br />

(d) if transparent or translucent surfaces in doors <strong>and</strong> g<strong>at</strong>es are not made of safety m<strong>at</strong>erial<br />

<strong>and</strong>, if <strong>the</strong>re is a danger th<strong>at</strong> employees may be injured if a door or g<strong>at</strong>e should sh<strong>at</strong>ter,<br />

<strong>the</strong> surfaces are protected against breakage,<br />

Transparent or translucent surfaces in doors <strong>and</strong> g<strong>at</strong>es should be made of m<strong>at</strong>erials which are safe or<br />

<strong>the</strong>y should be adequ<strong>at</strong>ely protected against breakage, particularly where any part of <strong>the</strong> transparent or<br />

translucent surface is <strong>at</strong> shoulder level (1,500 mm from floor level) or below.<br />

BS 6262-4:2005 on glazing for buildings may be a useful reference.<br />

(e) sliding doors <strong>and</strong> sliding g<strong>at</strong>es are fitted with a safety device <strong>to</strong> prevent <strong>the</strong>m from being<br />

derailed or falling over,<br />