Prodigy Cuber System Information<br />

Overall System Type:<br />

• Refrigeration: Mechanical, either air cooled, water cooled or remote cooled.<br />

• Water System: Inlet water solenoid valve fills reservoir once per cycle. Purge solenoid<br />

valve opens to discharge some reservoir water once per cycle.<br />

• Control System: Electronic<br />

• Harvest cycle sensor: Conductivity probe<br />

• Water full/empty sensor: Conductivity probe<br />

• Bin Control: Curtain Switch<br />

• Ice type: Unified<br />

• Harvest system: Hot gas defrost with mechanical assist<br />

Electrical Components:<br />

• Compressor<br />

• Contactor<br />

• Water Pump<br />

• Inlet Water Solenoid Valve<br />

• Purge or purge Valve<br />

• Fan Motor(s)<br />

• Fan motor pressure control<br />

• High pressure cut out – certain AC models only<br />

• Harvest Assist Solenoid(s)<br />

• Hot Gas Valve(s)<br />

• Controller<br />

• Transformer – 12v AC for the controller only<br />

• Water Level Sensor<br />

• Ice Thickness Sensor<br />

• Curtain Switch(es)<br />

September 2006 Page 21