Control Button Use - continued<br />

Change De-Scale Notification Interval<br />

Like the others, this feature is accessible only from standby (Status Light Off).<br />

1. Press and hold harvest button for 3 seconds.<br />

Starts the Time to Clean Adjustment State and displays the current time to clean setting.<br />

2. Press the clean button repeatedly to cycle through the 4 possible settings:<br />

Rev 5 and up (10/08 production start)<br />

• 1 year (8760 hours)<br />

• 0 (disabled)<br />

• 4 months (2920 hrs)<br />

• 6 months (4380 hours) (default)<br />

Prior<br />

• 6 months<br />

• 5 months<br />

• 4 months<br />

• 3 months<br />

3. Press Off or leave untouched for 60 seconds to select the displayed interval<br />

Test Mode Sequence Table - Air or Water Cooled<br />

Time (seconds) On Off<br />

0 WIV - 30 seconds WP, HGV, Comp, Fan, PV<br />

30 WP - 10 seconds WIV, HGV, Comp, Fan, PV<br />

40 WP, PV, HGV - 10 seconds WIV, Comp, Fan<br />

50 HGV, Comp - 5 seconds WIV, WP, Fan, PV<br />

55 Comp - 15 seconds WIV, HGV, WP, Fan, PV<br />

70 None - 5 seconds All<br />

75 HGV - 10 seconds WIV, WP, Comp, Fan, PV<br />

85 Fan - 10 seconds WIV, HGV, WP, Comp, PV<br />

95 None All – Test Complete<br />