Low Ice Making Capacity - Air Cooled<br />

Problem Likely Cause Probable Solution<br />

Long freeze cycle<br />

Long Harvest Cycle<br />

False bin full signal<br />

Dirty air filters<br />

Dirty condenser<br />

Hot ambient<br />

Water leak<br />

Water inlet valve leaks through<br />

Low on refrigerant<br />

Incorrect superheat<br />

Fan(s) cycle on and off<br />

Dirty evaporator<br />

No harvest assist<br />

Bridge thickness too big<br />

Machine in very cool ambient<br />

Ice jammed in between curtain<br />

and sump<br />

Curtain does not close correctly<br />

Clean filters<br />

Clean condenser<br />

Reduce room air temperature<br />

Check purge valve, check<br />

curtain<br />

Check inlet valve<br />

Add refrigerant, if cycle time<br />

drops, check for leak<br />

Check evaporator superheat, if<br />

significantly low or high,<br />

replace TXV<br />

Check pressures fans cycle at.<br />

Replace fan pressure switch if<br />

too low<br />

De-scale water system<br />

Check harvest assist solenoid<br />

Check and adjust bridge<br />

thickness<br />

Increase room temperature<br />

Clear ice away<br />

Check curtain for proper swing<br />