Diagnostics - Water Cooled<br />

No Ice<br />

Problem Likely Cause Probable Solution<br />

No power to unit<br />

Power disconnected<br />

Check breaker or fuse. Reset<br />

or replace, restart and check<br />

No power to controller Transformer open Replace transformer<br />

Shut down on<br />

maximum water fill<br />

time<br />

Shut down on<br />

maximum freeze time<br />

Water shut off<br />

Water leak<br />

Ice thickness sensor dirty or<br />

disconnected<br />

Water distributor dirty<br />

Inlet water valve leaks through<br />

during freeze<br />

Connected to hot water<br />

Incomplete harvest<br />

High pressure cut out opened<br />

Water pump not pumping<br />

Pump hose disconnected<br />

Compressor not operating<br />

Restore water supply<br />

Check purge valve, curtain,<br />

sump, pump hose<br />

Check ice thickness sensor<br />

probe<br />

Remove and clean water<br />

distributor<br />

Check inlet water valve<br />

Check for bleed thru from /<br />

missing check valve in building<br />

water supply<br />

Check harvest system<br />

Water supply cut off, restore<br />

water supply to condenser<br />

Check pump motor, check<br />

controller using test mode<br />

Check hose<br />

Check compressor contactor,<br />

check controller using test<br />

mode<br />

Check compressor start<br />

components, check PTCR<br />

resistance and temperature<br />

Check compressor voltage<br />

Check compressor windings<br />

September 2006 Page 47