Diagnostics – Air Cooled<br />

Problem Likely Cause Probable Solution<br />

Shut down on<br />

maximum freeze time<br />

Pump hose disconnected<br />

Compressor not operating<br />

Low refrigerant charge<br />

Hot gas valve leaks through<br />

during freeze<br />

Thermostatic expansion valve<br />

bulb loose<br />

Thermostatic expansion valve<br />

producing very low or very high<br />

superheat<br />

Compressor inefficient<br />

Check hose<br />

Check compressor contactor,<br />

check controller using test<br />

mode<br />

Check compressor start<br />

components, check PTCR<br />

resistance and temperature<br />

Check compressor voltage<br />

Check compressor windings<br />

Add some refrigerant and<br />

restart unit. If cycle time<br />

improves, look for leak.<br />

Check hot gas valve for hot<br />

outlet during freeze<br />

Check bulb<br />

Check evaporator superheat,<br />

change TXV if incorrect<br />

Check compressor amp draw,<br />

if low and all else is correct,<br />

change compressor<br />

September 2006 Page 43